Temporal Stability of Ciliary Beating Post Nasal Brushing, Modulated by Storage Temperature

被引:3
|
作者
Bricmont, Noemie [1 ,2 ]
Bonhiver, Romane [1 ,2 ]
Benchimol, Lionel [3 ]
Louis, Bruno [4 ]
Papon, Jean-Francois [4 ,5 ]
Monseur, Justine [6 ]
Donneau, Anne-Francoise [6 ]
Moermans, Catherine [1 ,7 ]
Schleich, Florence [1 ,7 ]
Calmes, Doriane [7 ]
Poirrier, Anne-Lise [3 ]
Louis, Renaud [1 ,7 ]
Seghaye, Marie-Christine [8 ]
Kempeneers, Celine [1 ,2 ]
机构
[1] Univ Liege, GIGA Res Ctr, Pneumol Lab, I3 Grp, B-4000 Liege, Belgium
[2] Univ Hosp Liege, Dept Pediat, Div Respirol, B-4000 Liege, Belgium
[3] Univ Hosp Liege, Dept ENT, B-4000 Liege, Belgium
[4] CNRS ERL7000, INSERM UPEC UMR 955, Inst Mondor Rech Biomed, F-94010 Creteil, France
[5] Univ Paris Saclay, Hop Bicetre, AP HP, ENT Dept, F-94270 Le Kremlin Bicetre, France
[6] Univ Liege, Biostat & Res Method Ctr, Publ Hlth Dept, B-4000 Liege, Belgium
[7] Univ Hosp Liege, Dept Pneumol, B-4000 Liege, Belgium
[8] Univ Liege, Univ Hosp Liege, Dept Pediat, Div Cardiol, B-4000 Liege, Belgium
关键词
cilia; ciliary beating; ciliary videomicroscopy; primary ciliary dyskinesia; FUNCTIONAL-ANALYSIS; PATTERN; DYSKINESIA; FREQUENCY;
D O I
10.3390/diagnostics13182974
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Primary ciliary dyskinesia is a heterogeneous, inherited motile ciliopathy in which respiratory cilia beat abnormally, and some ultrastructural ciliary defects and specific genetic mutations have been associated with particular ciliary beating alterations. Ciliary beating can be evaluated using digital high-speed videomicroscopy (DHSV). However, normal reference values, essential to assess ciliary beating in patients referred for a PCD diagnostic, vary between centres, as minor variations in protocols might influence ciliary beating. Consequently, establishment of normal values is essential for each PCD diagnostic centre. We aimed to evaluate whether delay after sampling, and temperature for conservation of respiratory ciliated samples, might modify assessments of ciliary beating. In total, 37 healthy nasal brushing samples of respiratory ciliated epithelia were collected. Video sequences were recorded at 37 degrees C immediately using DHSV. Then, the samples were divided and conserved at 4 degrees C or at room temperature (RT). Ciliated beating edges were then recorded at 37 degrees C, at 3 h and at 9 h post sampling. In six samples, recordings were continued up to 72 h after sampling. Ciliary beating was assessed manually by ciliary beat frequency (CBFM) and ciliary beat pattern (CBP). A semi-automatic software was used for quantitative analysis. Both CBF and CBP evaluated manually and by a semi-automated method were stable 9 h after sampling. CBFM was higher when evaluated using samples stored at RT than at 4 degrees C. CBP and the semi-automated evaluation of ciliary beating were not affected by storage temperature. When establishing normal references values, ciliary beating can be evaluated at 37 degrees C up to 9 h after nasal brushing, but the storage temperature modifies ciliary beating and needs to be controlled.
引用
收藏
页数:12
相关论文
共 4 条
  • [1] The effect of sodium fluoride, formaldehyde, and storage temperature on the stability of methamidophos in post-mortem blood and liver
    Wei, Zhiwen
    Niu, Qing
    Zhang, Fan
    Xiao, Kun
    Liu, Ling
    Wang, Yujin
    Jia, Juan
    Cao, Jie
    Fu, Shanlin
    Yun, Keming
    INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2017, 131 (03) : 667 - 675
  • [2] The effect of sodium fluoride, formaldehyde, and storage temperature on the stability of methamidophos in post-mortem blood and liver
    Zhiwen Wei
    Qing Niu
    Fan Zhang
    Kun Xiao
    Ling Liu
    Yujin Wang
    Juan Jia
    Jie Cao
    Shanlin Fu
    Keming Yun
    International Journal of Legal Medicine, 2017, 131 : 667 - 675
  • [3] Stability of Cryoprecipitate from Pathogen Reduced Apheresis Plasma: 2-year Frozen Storage Post-production and 120 Hours Storage at Room Temperature
    Krizanic, Katarina Kovacic
    Rosskopf, Konrad
    Payrat, Jean-Marc
    Andresen, Silke
    Pruller, Florian
    Schlenke, Peter
    TRANSFUSION, 2021, 61 : 72A - 72A
  • [4] Influence of corrosion-resistant coatings on the post-corrosion thermal stability and fouling of molten salts for high temperature thermal energy storage
    Kondaiah, P.
    Pitchumani, R.
    JOURNAL OF ENERGY STORAGE, 2024, 92