Background: Acetabular reconstruction options in the setting of substantial bone deficiency (Paprosky 3A and 3B) remain limited. Custom triflange acetabular implants are one choice for this challenging problem. However, few studies have reported on survivorship beyond 3 to 5 years. The purpose of this study was to report our 6 to 13-year clinical results using these custom-made acetabular components. Methods: Between 2008 and March 2015, 42 revision total hip arthroplasties (41 patients) were performed at our institution with a custom triflange acetabular component. All revisions involved either Paprosky 3A or 3B acetabular defects. Two patients died before the five-year follow-up. Harris Hip Scores were obtained at 6 months, 1 year, and every 2 to 3 years thereafter. The average follow-up in the remaining 40 revision total hip arthroplasties was 10 years (range, 6 to 13 years). Results: At the final follow-up, the mean Harris score was 74 points. There were two deep infections (5%). One custom implant was removed for deep infection (2.5%). Three hips (7.5%) experienced a total of four dislocations necessitating revision in one hip (femoral component only). One custom implant was judged to be loose. There were no cases of femoral nerve palsy. At final follow-up, 38 (95%) of the custom acetabular implants were considered radiographically stable. Conclusion: Instability and infection remain a major concern and cause of failure in these complex reconstructions. At an average follow-up of 10 years, however, custom triflange acetabular implants appear to work at least as well as jumbo cups and cup/cage constructs in the setting of extensive erosion of acetabular bone. (c) 2023 Elsevier Inc. All rights reserved.
引用
收藏
页码:S201 / S205
页数:5
相关论文
共 50 条
  • [41] Clinical experiences with laser-welded titanium frameworks supported by implants in the edentulous mandible:: A 10-year follow-up study
    Ortorp, Anders
    Jemt, Torsten
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2006, 8 (04) : 198 - 209
  • [42] Patients Who Underwent Primary Hip Arthroscopy for Femoroacetabular Impingement with Acetabular Microfracture Show 77% Survivorship at 10-Year Follow-Up
    Domb, Benjamin G.
    Lee, Michael S.
    Annin, Shawn
    Owens, Jade S.
    Jimenez, Andrew E.
    Sabetian, Payam W.
    Maldonado, David R.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2023, 39 (05) : 1185 - 1194
  • [43] Use of the Burch-Schneider cage and structural allografts in complex acetabular deficiency: 3-to 10-year follow up
    Hsu, Chieh-Cheng
    Hsu, Chi-Hsiang
    Yen, Shih-Hsiang
    Wang, Jun-Wen
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2015, 31 (10) : 540 - 547
  • [44] Tantalum Cones for Severe Bone Defects in Revision Knee Arthroplasty: A Minimum 10-Year Follow-Up
    De Martino, Ivan
    Mancino, Fabio
    Di Matteo, Vincenzo
    Singlitico, Alessandro
    Maccauro, Giulio
    Gasparini, Giorgio
    JOURNAL OF ARTHROPLASTY, 2023, 38 (05) : 886 - 892
  • [45] Periprosthetic BMD after cemented and uncemented total hip arthroplasty: a 10-year follow-up study
    Tapaninen, Toni
    Kroger, Heikki
    Venesmaa, Petri
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2015, 20 (04) : 657 - 662
  • [46] Acetabular Cup Revision With the Use of the Medial Protrusio Technique at an Average Follow-up of 6.6 Years
    Fabi, David
    Gonzalez, Mark
    Goldstein, Wayne
    Ahmed, Muhammad
    JOURNAL OF ARTHROPLASTY, 2010, 25 (02) : 197 - 202
  • [47] 10-year follow-up of the Columbus knee prostheses system in a prospective multicenter study
    Fuchs, Andreas
    Haeussermann, Philip
    Hoemig, Dirk
    Ochs, Bjorn Gunnar
    Klopfer, Tim
    Mueller, Christof A.
    Helwig, Peter
    Konstantinidis, Lukas
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2022, 142 (10) : 2875 - 2883
  • [48] Anaemia in inflammatory bowel disease: a population-based 10-year follow-up
    Hoivik, M. L.
    Reinisch, W.
    Cvancarova, M.
    Moum, B.
    ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2014, 39 (01) : 69 - 76
  • [49] Changes in the Volume and Diameter of Benign Thyroid Nodules: A 10-Year Follow-Up Study
    Erdogan, Murat Faik
    Bahcecioglu, Adile Begum
    Merdin, Fatma Avci
    Elhan, Atilla Halil
    Emral, Rifat
    Gullu, Sevim
    THYROID, 2025, 35 (01) : 31 - 40
  • [50] Large Bilateral Coronary Artery Fistula: 10-year Follow-up in Clinical Treatment
    Kulchetscki, Rodrigo Melo
    Lechinewski, Luka David
    Cascaes Dourado, Luciana Oliveira
    Hueb, Whady Armindo
    Machado Cesar, Luiz Antonio
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2019, 112 (02) : 211 - 213