Custom Triflange Acetabular Implants: Average 10-Year Follow-Up

被引:7
|
作者
Meding, John B. [1 ]
Meding, Lindsey K. [1 ]
机构
[1] Ctr Hip & Knee Surg, 1199 Hadley Rd, Mooresville, IN 46158 USA
关键词
triflange acetabular implants; revision total hip arthroplasty; acetabular bone loss; pelvic discontinuity; Paprosky 3A and 3B; TOTAL HIP-ARTHROPLASTY; PELVIC DISCONTINUITY; BONE LOSS; COMPONENTS; RECONSTRUCTION; MANAGEMENT; FIXATION; DEFECTS; CAGES;
D O I
10.1016/j.arth.2023.03.035
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Acetabular reconstruction options in the setting of substantial bone deficiency (Paprosky 3A and 3B) remain limited. Custom triflange acetabular implants are one choice for this challenging problem. However, few studies have reported on survivorship beyond 3 to 5 years. The purpose of this study was to report our 6 to 13-year clinical results using these custom-made acetabular components. Methods: Between 2008 and March 2015, 42 revision total hip arthroplasties (41 patients) were performed at our institution with a custom triflange acetabular component. All revisions involved either Paprosky 3A or 3B acetabular defects. Two patients died before the five-year follow-up. Harris Hip Scores were obtained at 6 months, 1 year, and every 2 to 3 years thereafter. The average follow-up in the remaining 40 revision total hip arthroplasties was 10 years (range, 6 to 13 years). Results: At the final follow-up, the mean Harris score was 74 points. There were two deep infections (5%). One custom implant was removed for deep infection (2.5%). Three hips (7.5%) experienced a total of four dislocations necessitating revision in one hip (femoral component only). One custom implant was judged to be loose. There were no cases of femoral nerve palsy. At final follow-up, 38 (95%) of the custom acetabular implants were considered radiographically stable. Conclusion: Instability and infection remain a major concern and cause of failure in these complex reconstructions. At an average follow-up of 10 years, however, custom triflange acetabular implants appear to work at least as well as jumbo cups and cup/cage constructs in the setting of extensive erosion of acetabular bone. (c) 2023 Elsevier Inc. All rights reserved.
引用
收藏
页码:S201 / S205
页数:5
相关论文
共 50 条
  • [31] Acetabular Reconstruction Using a Kerboull Cross-Plate, Structural Allograft and Cemented Dual-Mobility Cup in Revision THA at a Minimum 5-Year Follow-Up
    Wegrzyn, Julien
    Pibarot, Vincent
    Jacquel, Alexandre
    Carret, Jean-Paul
    Bejui-Hugues, Jacques
    Guyen, Olivier
    JOURNAL OF ARTHROPLASTY, 2014, 29 (02) : 432 - 437
  • [32] Revision Total Hip Arthroplasty Using a Cementless Cup Supporter and Iliac Autograft: A Minimum of 15-Year Follow-Up
    Yoshino, Kensuke
    Tsukeoka, Tadashi
    Tsuneizumi, Yoshikazu
    Lee, Tae Hyun
    Nakamura, Junichi
    Suzuki, Masahiko
    Ohtori, Seiji
    JOURNAL OF ARTHROPLASTY, 2017, 32 (11) : 3495 - 3501
  • [33] Outcomes of an acute care surgery model: a 10-year follow-up study
    Kaya, Cigdem
    Yang, Phillip F.
    Wong, Shing W.
    Truskett, Philip G.
    ANZ JOURNAL OF SURGERY, 2020, 90 (03) : 257 - 261
  • [34] Complex Rehabilitation for an Adolescent with Ectodermal Dysplasia-A 10-Year Follow-Up
    Sun, Xiaodi
    Yang, Jing
    Ma, Xiaoli
    Liu, Songyun
    Zhang, Jian
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2021, 30 (01): : 7 - 12
  • [35] Radiologists are increasingly recommending follow-up of chest radiographs: a 10-year review
    Heaney, A. M.
    O'Rourke, C.
    Hunter, K.
    Torreggiani, W. C.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2021, 190 (01) : 367 - 372
  • [36] Five- and 10-Year Follow-Up of Nonvascularized Toe Phalanx Transfers
    Kawabata, Hidehiko
    Tamura, Daisuke
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2018, 43 (05): : 485.e1 - 485.e5
  • [37] Results of 10-year follow-up of the iliac donor site of graft patients
    Qi, Liqing
    Liu, Yueju
    Li, Han
    Zhang, Yingze
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2014, 42 (06) : 1348 - 1352
  • [38] Stereotactic radiosurgery for vestibular schwannomas: average 10-year follow-up results focusing on long-term hearing preservation
    Watanabe, Shinya
    Yamamoto, Masaaki
    Kawabe, Takuya
    Koiso, Takao
    Yamamoto, Tetsuya
    Matsumura, Akira
    Kasuya, Hidetoshi
    JOURNAL OF NEUROSURGERY, 2016, 125 : 64 - 72
  • [39] Clinical and Radiographic Results for the Richards Modular Hip System Prosthesis in Total Hip Arthroplasty Average 10-Year Follow-Up
    Suehara, Hiroshi
    Fujioka, Mikihiro
    Inoue, Shigehiro
    Takahashi, Kenji
    Ueshima, Keiichiro
    Kubo, Toshikazu
    JOURNAL OF ARTHROPLASTY, 2010, 25 (03) : 369 - 374
  • [40] Prosthetic rehabilitation of maxillary lateral incisors agenesis using dental mini-implants: a multicenter 10-year follow-up
    Lacarbonara, M.
    Cazzolla, A. P.
    Lacarbonara, V.
    Lo Muzio, L.
    Ciavarella, D.
    Testa, N. F.
    Crincoli, V.
    Di Venere, D.
    De Franco, A.
    Tripodi, D.
    Grassi, F. R.
    Capogreco, M.
    CLINICAL ORAL INVESTIGATIONS, 2022, 26 (02) : 1963 - 1974