Custom Triflange Acetabular Implants: Average 10-Year Follow-Up

被引:7
|
作者
Meding, John B. [1 ]
Meding, Lindsey K. [1 ]
机构
[1] Ctr Hip & Knee Surg, 1199 Hadley Rd, Mooresville, IN 46158 USA
关键词
triflange acetabular implants; revision total hip arthroplasty; acetabular bone loss; pelvic discontinuity; Paprosky 3A and 3B; TOTAL HIP-ARTHROPLASTY; PELVIC DISCONTINUITY; BONE LOSS; COMPONENTS; RECONSTRUCTION; MANAGEMENT; FIXATION; DEFECTS; CAGES;
D O I
10.1016/j.arth.2023.03.035
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Acetabular reconstruction options in the setting of substantial bone deficiency (Paprosky 3A and 3B) remain limited. Custom triflange acetabular implants are one choice for this challenging problem. However, few studies have reported on survivorship beyond 3 to 5 years. The purpose of this study was to report our 6 to 13-year clinical results using these custom-made acetabular components. Methods: Between 2008 and March 2015, 42 revision total hip arthroplasties (41 patients) were performed at our institution with a custom triflange acetabular component. All revisions involved either Paprosky 3A or 3B acetabular defects. Two patients died before the five-year follow-up. Harris Hip Scores were obtained at 6 months, 1 year, and every 2 to 3 years thereafter. The average follow-up in the remaining 40 revision total hip arthroplasties was 10 years (range, 6 to 13 years). Results: At the final follow-up, the mean Harris score was 74 points. There were two deep infections (5%). One custom implant was removed for deep infection (2.5%). Three hips (7.5%) experienced a total of four dislocations necessitating revision in one hip (femoral component only). One custom implant was judged to be loose. There were no cases of femoral nerve palsy. At final follow-up, 38 (95%) of the custom acetabular implants were considered radiographically stable. Conclusion: Instability and infection remain a major concern and cause of failure in these complex reconstructions. At an average follow-up of 10 years, however, custom triflange acetabular implants appear to work at least as well as jumbo cups and cup/cage constructs in the setting of extensive erosion of acetabular bone. (c) 2023 Elsevier Inc. All rights reserved.
引用
收藏
页码:S201 / S205
页数:5
相关论文
共 50 条
  • [21] Fixation and Wear With a Contemporary Acetabular Component and Cross-Linked Polyethylene at Minimum 10-Year Follow-Up
    Bedard, Nicholas A.
    Callaghan, John J.
    Stefl, Michael D.
    Willman, Tyler J.
    Liu, Steve S.
    Goetz, Devon D.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (10) : 1961 - 1969
  • [22] The expanded role of the transplant pharmacist: A 10-year follow-up
    Lichvar, Alicia Beth
    Chandran, Mary Moss
    Cohen, Elizabeth A.
    Crowther, Barrett R.
    Doligalski, Christina Teeter
    Martinez, Amanda J. Condon
    Potter, Lisa M. M.
    Taber, David J.
    Alloway, Rita R.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2023, 23 (09) : 1375 - 1387
  • [23] Trabecular titanium cups in acetabular revision arthroplasty: analysis of 10-year survivorship, restoration of center of rotation and osteointegration
    Lepri, Andrea Cozzi
    Innocenti, Matteo
    Galeotti, Alberto
    Carulli, Christian
    Villano, Marco
    Civinini, Roberto
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2022, 142 (11) : 3523 - 3531
  • [24] A 2-to 7-Year Follow-Up of a Modular Iliac Screw Cup in Major Acetabular Defects Clinical, Radiographic and Survivorship Analysis With Comparison to the Literature
    Cadossi, Matteo
    Garcia, Flavio Luis
    Sambri, Andrea
    Andreoli, Isabella
    Dallari, Dante
    Pignatti, Giovanni
    JOURNAL OF ARTHROPLASTY, 2017, 32 (01) : 207 - 213
  • [25] Effect of Blood Pressure on Cardiovascular Diseases at 10-Year Follow-Up
    Cho, Nam Han
    Rak, Young
    Park, Mi Kyoung
    Kim, Duk Kyu
    Shin, Chol
    Lee, Moon-Kyu
    Suh, Sunghwan
    AMERICAN JOURNAL OF CARDIOLOGY, 2019, 123 (10) : 1654 - +
  • [26] Custom-made triflanged implants in reconstruction of severe acetabular bone loss with pelvic discontinuity after total hip arthroplasty consecutive cohort study TWO TO 11 YEARS OF FOLLOW-UP
    Winther, S. S.
    Petersen, M.
    Yilmaz, M.
    Kaltoft, N. S.
    Sturup, J.
    Winther, N. S.
    BONE & JOINT OPEN, 2022, 3 (11): : 867 - 876
  • [27] Marginal Bone Loss Around One-Piece Implants: A 10-Year Radiological and Clinical Follow-up Evaluation
    Kadkhodazadeh, Mahdi
    Safi, Yaser
    Moeintaghavi, Amir
    Amid, Reza
    Baghani, Mohammad Taghi
    Shidfar, Shireen
    IMPLANT DENTISTRY, 2019, 28 (03) : 237 - 243
  • [28] Cementless Metal-Backed Patellar Components in Primary Total Knee Arthroplasty: An Average 10-Year Follow-Up
    Jouflas, Alex C.
    Nadar, Arun C.
    Royster, Brett W.
    Smith, Langan S.
    Ziegele, Michael J.
    Yakkanti, Madhusudhan R.
    Malkani, Arthur L.
    JOURNAL OF ARTHROPLASTY, 2023, 38 (06) : S137 - S144
  • [29] Long-term results of isolated acetabular revisions with reinforcement rings: a 10-to 15-year follow-up
    Marongiu, Giuseppe
    Podda, Daniele
    Mastio, Michele
    Capone, Antonio
    HIP INTERNATIONAL, 2019, 29 (04) : 385 - 392
  • [30] Treatment for acetabular dysplasia using the uncemented RM acetabular component - a 20 year follow-up
    Ihle, Martin
    Mai, Sabine
    Siebert, Werner E.
    HIP INTERNATIONAL, 2010, 20 (01) : 94 - 101