DESIGN OF PATIENT SPECIFIC HIP PROSTHESIS BASED ON FINITE ELEMENT ANALYSIS: A COMPARATIVE STUDY

被引:2
|
作者
Snekhalatha, U. [1 ,2 ,5 ]
Dhason, Raja [3 ]
Rajalakshmi, T. [4 ]
机构
[1] SRM Inst Sci & Technol, Coll Engn & Technol, Dept Biomed Engn, Kattankulathur, India
[2] Batangas State Univ, Coll Engn & Fine Arts, Batangas, Philippines
[3] SRM Inst Sci & Technol, Coll Engn & Technol, Dept Mech Engn, Kattankulathur, India
[4] SRM Inst Sci & Technol, Coll Engn & Technol, Dept Elect & Commun Engn, Chennai, India
[5] SRM Inst Sci & Technol, Dept Biomed Engn, Kattankulathur, Tamil Nadu, India
来源
BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS | 2023年 / 35卷 / 04期
关键词
Finite element analysis; Customized hip implant; Conventional hip implant; Femur bone; ARTHROPLASTY; RANGE;
D O I
10.4015/S1016237223500175
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study aims to develop a patient-specific hip implant for osteoarthritis conditions and to compare with intact and conventional implant. The femoral bone with head and shaft region was segmented from the pelvic griddle and converted into 3D model. The parameters such as femoral ball diameter, shaft length, acetabular cup diameter, and neck angle were measured from the segmented 3D model. In this study, designed part of hip implant was assembled together to form a customized hip implant. The von Mises stress was measured by means of Finite element analysis (FEA) method by applying various forces applied at the distal end of hip implant. The forces applied at hip implant were based on the assumption of 500 N force for standing, 2000 N force for walking, and 3000 N force for jogging condition. The minimum stress attained at the femur bone of custom-model is 1.32 MPa for 500 N loading condition, 5.3 MPa for 2000 N and 7.96 MPa for the maximum load of 3000 N. Thus the customized model experienced better stress distribution compared to conventional model under the maximum load of 3000 N. In pelvic region, the custom model attained a lower stress of 23% compared to conventional model. Thus, the study recommends the customized hip implants for the osteoarthritis conditions to avoid revision surgery.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Biomechanical Analysis of Hip Replacement Stem Design: A Finite Element Analysis
    Azbari, Zahra Shamsipour
    Rad, Mohadese Rajaei
    Nahvinejad, Amirreza
    Gilakjani, Hasan Asadi
    Khorsandi, Mohammad
    2022 29TH NATIONAL AND 7TH INTERNATIONAL IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING, ICBME, 2022, : 305 - 309
  • [22] Finite element analysis of a stemmed hip prosthesis to reduce stress shielding in the proximal femur
    Bliss, Oliver
    Swadener, J. Greg
    Pearce, Gillian
    Zidane, Iham F.
    JOURNAL OF MECHANICAL ENGINEERING AND SCIENCES, 2023, 17 (01) : 9349 - 9359
  • [23] Cause analysis of the liner dissociation of a customized reverse shoulder prosthesis based on finite element analysis
    Wan, Qian
    Zhang, Aobo
    Bai, Haotian
    Liu, Yang
    Chen, Hao
    Zhao, Xin
    Wang, Xiaonan
    Han, Qing
    Wang, Jincheng
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [24] Stress analysis of glenoid component in design of reverse shoulder prosthesis using finite element method
    Yang, Ching-Chieh
    Lu, Chun-Lin
    Wu, Chun-Hung
    Wu, Jiunn-Jer
    Huang, Teng-Le
    Chen, Rongshun
    Yeh, Meng-Kao
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2013, 22 (07) : 932 - 939
  • [25] Finite Element Analysis of Patient-Specific Femur Bone for Synthetic Biomaterials
    Khare, Navneet
    Sharma, Gorang
    Modi, Yashwant Kumar
    ADVANCES IN MECHANICAL ENGINEERING, ICRIDME 2018, 2020, : 649 - 659
  • [26] Contact pressure distribution of the hip joint during closed reduction of developmental dysplasia of the hip: a patient-specific finite element analysis
    Zhiqiang Zhang
    Dashan Sui
    Haiyi Qin
    Hai Li
    Ziming Zhang
    BMC Musculoskeletal Disorders, 21
  • [27] Contact pressure distribution of the hip joint during closed reduction of developmental dysplasia of the hip: a patient-specific finite element analysis
    Zhang, Zhiqiang
    Sui, Dashan
    Qin, Haiyi
    Li, Hai
    Zhang, Ziming
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [28] Finite element analysis of intraosseous distal radioulnar joint prosthesis
    Gholamian, Farzaneh
    Ashrafi, Mehran
    Moradi, Ali
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [29] Finite Element Analysis of Patient-Specific Condyle Fracture Plates: A Preliminary Study
    Aquilina, Peter
    Parr, William C. H.
    Chamoli, Uphar
    Wroe, Stephen
    CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2015, 8 (02) : 111 - 116
  • [30] Biomechanical Comparison of A New Stemless Hip Prosthesis with Different Shapes-A Finite Element Analysis
    Chen, Tain-Hsiung
    Lung, Chen-Yu
    Cheng, Cheng-Kung
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 29 (03) : 108 - 113