Study on the influencing factors on indoor PM2.5 of office buildings in beijing based on statistical and machine learning methods

被引:13
作者
Li, Zehao [1 ]
Di, Zhenzhen [1 ]
Chang, Miao [1 ]
Zheng, Ji [1 ]
Tanaka, Toshio [2 ]
Kuroi, Kiyoshi [2 ]
机构
[1] Tsinghua Univ, Sch Environm, Beijing 100084, Peoples R China
[2] Daikin Ind Ltd, Osaka 5308323, Japan
关键词
Indoor air quality; PM2; 5; Contribution; Office buildings; IoT devices; WINDOW-OPENING BEHAVIOR; OUTDOOR AIR-QUALITY; PARTICULATE MATTER; COMMERCIAL BUILDINGS; EXPOSURE; PARTICLES; POLLUTION; IMPACT; PENETRATION; OCCUPANTS;
D O I
10.1016/j.jobe.2022.105240
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To investigate the interactions and contributions of the influencing factors on indoor PM2.5, indoor monitoring data (including PM2.5, CO2, temperature, humidity, and window states) at six office buildings sites in Beijing and outdoor air quality and meteorological data at nearby national sites were collected and analyzed. Seemingly unrelated estimation (SUEST) tests and decision tree models were conducted, and results indicated that opening windows increased the infiltration factor and decreased the impact of indoor sources, while it may not be effective enough to remove indoor particles in some conditions. Besides, the influence of factors is nonlinear, and the correlations between factors make the form of cross-terms complex. The contribution of outdoor PM2.5 and periodic factors adds up to 68.43 & PLUSMN; 6.07%, and the main differences among the results are reflected in the allocation of these factors. Outdoor PM2.5 is shown to play the most important role in the variation of indoor PM2.5 in most office spaces (49.55 & PLUSMN; 16.87%). Periodic factors and personnel activities are significant (16.34 & PLUSMN; 10.02%) and strong personnel activities seemed to increase the impact of periodic factors on indoor PM2.5, while the impact of window states is limited (3.41 & PLUSMN; 2.63%). The contribution of outdoor meteorology and indoor environment is 11.89 & PLUSMN; 2.63% and 16.26 & PLUSMN; 4.40% respectively. The influence of wind direction is stronger than that of wind speed, and temperature and humidity were shown to be equally important in the variation of indoor PM2.5. The data and results can provide suggestions for indoor air quality management, and the methods proposed in this study can be used to evaluate the impact of other factors on indoor air quality based on long-term monitoring data.
引用
收藏
页数:14
相关论文
共 84 条
[41]   Exposure assessments for children in homes and in daycare centers to NO2, PMs and black carbon [J].
Lee J.Y. ;
Kim C. ;
Kim J. ;
Ryu S.H. ;
Bae G.-N. .
Asian Journal of Atmospheric Environment, 2018, 12 (3) :204-214
[42]   Outdoor-indoor air pollution in urban environment: challenges and opportunity [J].
Leung, Dennis Y. C. .
FRONTIERS IN ENVIRONMENTAL SCIENCE, 2015, 2
[43]   A Review of Recent Advances in Research on PM2.5 in China [J].
Lin, Yaolin ;
Zou, Jiale ;
Yang, Wei ;
Li, Chun-Qing .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2018, 15 (03)
[44]   Viable influenza A virus in airborne particles expelled during coughs versus exhalations [J].
Lindsley, William G. ;
Blachere, Francoise M. ;
Beezhold, Donald H. ;
Thewlis, Robert E. ;
Noorbakhsh, Bahar ;
Othumpangat, Sreekumar ;
Goldsmith, William T. ;
McMillen, Cynthia M. ;
Andrew, Michael E. ;
Burrell, Carmen N. ;
Noti, John D. .
INFLUENZA AND OTHER RESPIRATORY VIRUSES, 2016, 10 (05) :404-413
[45]   Relations between indoor and outdoor PM2.5 and constituent concentrations [J].
Liu, Cong ;
Zhang, Yinping .
FRONTIERS OF ENVIRONMENTAL SCIENCE & ENGINEERING, 2019, 13 (01)
[46]   Theoretical model of buoyancy-driven air infiltration during heating/cooling seasons in large space buildings [J].
Liu, Xiaochen ;
Liu, Xiaohua ;
Zhang, Tao .
BUILDING AND ENVIRONMENT, 2020, 173
[47]   An Experimental Study of Permeability Characteristics of Outdoor Particles under Indoor and Outdoor Temperature Differences [J].
Lu, Yuxin ;
Qiu, Jiayi ;
Liu, Yanhua .
10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 :226-232
[48]   Determining Building Natural Ventilation Potential via IoT-Based Air Quality Sensors [J].
Luo, Maohui ;
Hong, Yumeng ;
Pantelic, Jovan .
FRONTIERS IN ENVIRONMENTAL SCIENCE, 2021, 9
[49]   The Correlation between Indoor and Outdoor Particulate Matter of Different Building Types in Daqing, China [J].
Lv, Yang ;
Wang, Haifeng ;
Wei, Shanshan ;
Zhang, Lei ;
Zhao, Qi .
10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 :360-367
[50]   Impact of PM2.5 in indoor urban environments: A review [J].
Martins, Nuno R. ;
da Graca, Guilherme Carrilho .
SUSTAINABLE CITIES AND SOCIETY, 2018, 42 :259-275