Etch-and-rinse versus self-etch strategy of a universal adhesive in different application methods at the bonding interface of fiber post cementation

被引:8
|
作者
Oliveira Barros, Antonia Patricia [1 ]
Alencar, Cristiane de Melo [2 ]
Zambon, Matheus [1 ]
de Andrade, Marcelo Ferrarezi [1 ]
Fernandez, Eduardo [3 ]
Kuga, Milton Carlos [1 ]
机构
[1] Sao Paulo State Univ UNESP, Araraquara Dent Sch, Dept Operat Dent, Araraquara, Brazil
[2] Univ Ctr State Para, Sch Dent, Dept Restorat Dent, Belem, Brazil
[3] Univ Autonoma Chile, Inst Ciencias Biomed, Santiago, Chile
关键词
adhesive; bond strength; cementation; failure; fiber post; protocols; SONIC APPLICATION MODE; ROOT-CANAL WALLS; STRENGTH; DENTIN; SYSTEMS; PERFORMANCE;
D O I
10.1111/jerd.13068
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectiveTo evaluate the effect of etch-and-rinse (ER) versus self-etch (SE) strategies of a universal adhesive applied with a manual brush (MB) or rotary brush (RB) on the bonding interface of fiber post cementation. MethodsForty bovine incisor roots were prepared and divided into four groups according to the methods of application and strategy of universal adhesive use (MB-ER, RB-ER, MB-SE and RB-SE). After 6 months, specimens from different thirds of the post space were evaluated of push-out strength, analysis of adhesive failure patterns, and extent of tags. ResultsThe RB-ER and RB-SE groups showed the highest bond strength values in the cervical and middle thirds of the post space. Cohesive adhesive failure had the highest incidence in the different thirds of the post space in the ER strategy, regardless of the adhesive application method. The RB-ER group showed the highest tag extensions. ConclusionsThe protocols of universal adhesive application with RB provided the greater bond strength, but only the ER strategy favored the formation of a greater extension of tags at the adhesive interface. Clinical SignificanceThe application of universal adhesive with RB into the post space increases the strength of the post-cemented fiber bond.
引用
收藏
页码:1249 / 1256
页数:8
相关论文
共 50 条
  • [31] Effect of different self-etch adhesive application methods on the shear bond strengths of composite resin to dentin
    Kerekes-Mathe, Bernadette
    Szekely, Melinda
    Csiszer, Orsolya
    Kis, Melinda
    Nimigean, Vanda Roxana
    Nimigean, Victor
    Dorner, Kinga
    ROMANIAN BIOTECHNOLOGICAL LETTERS, 2020, 25 (06): : 2188 - 2193
  • [32] Mechanical properties and degree of conversion of etch-and-rinse and self-etch adhesive systems cured by a quartz tungsten halogen lamp and a light-emitting diode
    Gaglianone, Livia Aguilera
    Lima, Adriano Fonseca
    Goncalves, Luciano Souza
    Cavalcanti, Andrea Nobrega
    Baggio Aguiar, Flavio Henrique
    Marchi, Giselle Maria
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2012, 12 : 139 - 143
  • [33] Does dimethyl sulfoxide promote the bonding performance of different universal adhesives to dentin in etch-and-rinse approach?
    Karadas, Muhammet
    Atmaca, Yakup
    Ozden, Gulsum
    INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2023, 127
  • [34] A 12-month clinical evaluation of pit-and-fissure sealants placed with and without etch-and-rinse and self-etch adhesive systems in newly-erupted teeth
    Nogourani, Maryam Karami
    Janghorbani, Mohsen
    Khadem, Parvin
    Jadidi, Zahra
    Jalali, Shahriar
    JOURNAL OF APPLIED ORAL SCIENCE, 2012, 20 (03) : 352 - 356
  • [35] Resin-enamel microtensile bond strength evaluation of two universal adhesive systems in both etch-&-rinse and self-etch approach
    Polido, M.
    Moreno, P.
    Santos, M.
    Brito, J.
    Azul, A. C.
    ANNALS OF MEDICINE, 2018, 50 : S62 - S63
  • [36] Effect of different disinfectant methods on the initial microtensile bond strength of a self-etch adhesive to dentin
    Dalkilic, Evrim Eliguzeloglu
    Arisu, Hacer Deniz
    Kivanc, Bagdagul Helvacioglu
    Uctasli, Mine Betul
    Omurlu, Huma
    LASERS IN MEDICAL SCIENCE, 2012, 27 (04) : 819 - 825
  • [37] Eight-year randomized clinical evaluation of Class II nanohybrid resin composite restorations bonded with a one-step self-etch or a two-step etch-and-rinse adhesive
    van Dijken, Jan W. V.
    Pallesen, Ulla
    CLINICAL ORAL INVESTIGATIONS, 2015, 19 (06) : 1371 - 1379
  • [38] Influence of laboratory degradation methods and bonding application parameters on μTBS of self-etch adhesives to dentin
    Erhardt, Maria Carolina G.
    Pisani-Proenca, Jatyr
    Osorio, Estrella
    Aguilera, Fatima S.
    Toledano, Manuel
    Osorio, Raquel
    AMERICAN JOURNAL OF DENTISTRY, 2011, 24 (02) : 103 - 108
  • [39] Evaluation of the efficacy of a 2-step etch-and-rinse, 2-step self-etch and 1-step self-etch adhesive systems, in class II primary molars restorations. An one year prospective, randomized clinical trial
    Soares, A. D.
    Ramos, J. C.
    Alves, L. C.
    Pereira, J. L.
    Caramelo, F.
    Costa, A. L.
    EUROPEAN ARCHIVES OF PAEDIATRIC DENTISTRY, 2022, 23 (05) : 845 - 854
  • [40] Comparison of different etch-and-rinse adhesive systems based on shear fatigue dentin bond strength and morphological features the interface
    Kasahara, Yuta
    Takamizawa, Toshiki
    Hirokane, Eizo
    Tsujimoto, Akimasa
    Ishii, Ryo
    Barkmeier, Wayne W.
    Latta, Mark A.
    Miyazaki, Masashi
    DENTAL MATERIALS, 2021, 37 (03) : E109 - E117