Validation of an EMG submaximal method to calibrate a novel dynamic EMG-driven musculoskeletal model of the trunk: Effects on model estimates

被引:5
|
作者
Eskandari, Amir Hossein [1 ]
Ghezelbash, Farshid [2 ]
Shirazi-Adl, Aboulfazl [2 ]
Gagnon, Denis [3 ]
Mecheri, Hakim [1 ]
Lariviere, Christian [1 ,4 ,5 ]
机构
[1] Inst Rech Robert Sauveen Sante Secur Travail, Montreal, PQ, Canada
[2] Polytech Montreal, Dept Mech Engn, Div Appl Mech, Montreal, PQ, Canada
[3] Univ Sherbrooke, Dept Phys Act Sci, Sherbrooke, PQ, Canada
[4] Inst Univ Readaptat Deficience Phys Montreal IURD, Ctr Interdisciplinary Res Rehabil Greater Montrea, Ctr Integre Univ Sante & Serv Sociaux Ctr Sud Del, Montreal, PQ, Canada
[5] Inst Rech Robert Sauveen St e et en Securite du T, 505 Boul Maisonneuve Ouest, Montreal H3A 3C2, PQ, Canada
关键词
Musculoskeletal Modeling; Electromyography; Model calibration; Spine biomechanics; Back pain; MUSCLE FORCES; SPINAL LOADS; STABILITY; OPTIMIZATION; JOINT; COCONTRACTION; KINEMATICS; GENERATION; PATTERNS; MOMENTS;
D O I
10.1016/j.jelekin.2022.102728
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: Multijoint EMG-assisted optimization models are reliable tools to predict muscle forces as they account for inter- and intra-individual variations in activation. However, the conventional method of normalizing EMG signals using maximum voluntary contractions (MVCs) is problematic and introduces major limitations. The sub-maximal voluntary contraction (SVC) approaches have been proposed as a remedy, but their performance against the MVC approach needs further validation particularly during dynamic tasks. Methods: To compare model outcomes between MVC and SVC approaches, nineteen healthy subjects performed a dynamic lifting task with two loading conditions. Results: Results demonstrated that these two approaches produced highly correlated results with relatively small absolute and relative differences (<10 %) when considering highly-aggregated model outcomes (e.g. compression forces, stability indices). Larger differences were, however, observed in estimated muscle forces. Although some model outcomes, e.g. force of abdominal muscles, were statistically different, their effect sizes remained mostly small (eta 2G <= 0.13) and in a few cases moderate (eta 2G <= 0.165). Conclusion: The findings highlight that the MVC calibration approach can reliably be replaced by the SVC approach when the true MVC exertion is not accessible due to pain, kinesiophobia and/or the lack of proper training.
引用
收藏
页数:9
相关论文
共 43 条
  • [21] Ankle Joint Torque Estimation Using an EMG-Driven Neuromusculoskeletal Model and an Artificial Neural Network Model
    Zhang, Longbin
    Li, Zhijun
    Hu, Yingbai
    Smith, Christian
    Farewik, Elena M. Gutierrez
    Wang, Ruoli
    IEEE TRANSACTIONS ON AUTOMATION SCIENCE AND ENGINEERING, 2021, 18 (02) : 564 - 573
  • [22] The effectiveness of EMG-driven neuromusculoskeletal model calibration is task dependent
    Kian, Azadeh
    Pizzolato, Claudio
    Halaki, Mark
    Ginn, Karen
    Lloyd, David
    Reed, Darren
    Ackland, David
    JOURNAL OF BIOMECHANICS, 2021, 129
  • [23] A Subject-Specific EMG-Driven Musculoskeletal Model for Applications in Lower-Limb Rehabilitation Robotics
    Ai, Qingsong
    Ding, Bo
    Liu, Quan
    Meng, Wei
    INTERNATIONAL JOURNAL OF HUMANOID ROBOTICS, 2016, 13 (03)
  • [24] A Hill-based EMG-driven model to estimate elbow torque during flexion and extention
    Qashqai, Anahita
    Ehsani, Hossein
    Rostami, Mostafa
    2015 22ND IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING (ICBME), 2015, : 166 - 171
  • [25] A Lower Limb EMG-driven Biomechanical Model for Applications in Rehabilitation Robotics
    Sartori, Massimo
    Reggiani, Monica
    Mezzato, Cristiano
    Pagello, Enrico
    ICAR: 2009 14TH INTERNATIONAL CONFERENCE ON ADVANCED ROBOTICS, VOLS 1 AND 2, 2009, : 905 - +
  • [26] EMG-driven hand model based on the classification of individual finger movements
    Arteaga, Maria V.
    Castiblanco, Jenny C.
    Mondragon, Ivan F.
    Colorado, Julian D.
    Alvarado-Rojas, Catalina
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2020, 58
  • [27] AN EMG-DRIVEN FORWARD DYNAMICS MODEL TO SIMULATE STANCE PHASE OF GAIT
    Shao, Qi
    Manal, Kurt
    Buchanan, Thomas S.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2009, PT A AND B, 2009, : 1217 - 1218
  • [28] EMG Validation of a Subject-Specific Thoracolumbar Spine Musculoskeletal Model During Dynamic Activities in Older Adults
    Alemi, Mohammad Mehdi
    Banks, Jacob J. J.
    Lynch, Andrew C. C.
    Allaire, Brett T. T.
    Bouxsein, Mary L. L.
    Anderson, Dennis E. E.
    ANNALS OF BIOMEDICAL ENGINEERING, 2023, 51 (10) : 2313 - 2322
  • [29] Numerical validation of a subject-specific parameter identification approach of a quadriceps femoris EMG-driven model
    Heine, Claudio Bastos
    Menegaldo, Luciano Luporini
    MEDICAL ENGINEERING & PHYSICS, 2018, 53 : 66 - 74
  • [30] An EMG-Driven Biomechanical Model That Accounts for the Decrease in Moment Generation Capacity During a Dynamic Fatigued Condition
    Rao, Guillaume
    Berton, Eric
    Amarantini, David
    Vigouroux, Laurent
    Buchanan, Thomas S.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2010, 132 (07):