Validation of an EMG submaximal method to calibrate a novel dynamic EMG-driven musculoskeletal model of the trunk: Effects on model estimates

被引:5
|
作者
Eskandari, Amir Hossein [1 ]
Ghezelbash, Farshid [2 ]
Shirazi-Adl, Aboulfazl [2 ]
Gagnon, Denis [3 ]
Mecheri, Hakim [1 ]
Lariviere, Christian [1 ,4 ,5 ]
机构
[1] Inst Rech Robert Sauveen Sante Secur Travail, Montreal, PQ, Canada
[2] Polytech Montreal, Dept Mech Engn, Div Appl Mech, Montreal, PQ, Canada
[3] Univ Sherbrooke, Dept Phys Act Sci, Sherbrooke, PQ, Canada
[4] Inst Univ Readaptat Deficience Phys Montreal IURD, Ctr Interdisciplinary Res Rehabil Greater Montrea, Ctr Integre Univ Sante & Serv Sociaux Ctr Sud Del, Montreal, PQ, Canada
[5] Inst Rech Robert Sauveen St e et en Securite du T, 505 Boul Maisonneuve Ouest, Montreal H3A 3C2, PQ, Canada
关键词
Musculoskeletal Modeling; Electromyography; Model calibration; Spine biomechanics; Back pain; MUSCLE FORCES; SPINAL LOADS; STABILITY; OPTIMIZATION; JOINT; COCONTRACTION; KINEMATICS; GENERATION; PATTERNS; MOMENTS;
D O I
10.1016/j.jelekin.2022.102728
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: Multijoint EMG-assisted optimization models are reliable tools to predict muscle forces as they account for inter- and intra-individual variations in activation. However, the conventional method of normalizing EMG signals using maximum voluntary contractions (MVCs) is problematic and introduces major limitations. The sub-maximal voluntary contraction (SVC) approaches have been proposed as a remedy, but their performance against the MVC approach needs further validation particularly during dynamic tasks. Methods: To compare model outcomes between MVC and SVC approaches, nineteen healthy subjects performed a dynamic lifting task with two loading conditions. Results: Results demonstrated that these two approaches produced highly correlated results with relatively small absolute and relative differences (<10 %) when considering highly-aggregated model outcomes (e.g. compression forces, stability indices). Larger differences were, however, observed in estimated muscle forces. Although some model outcomes, e.g. force of abdominal muscles, were statistically different, their effect sizes remained mostly small (eta 2G <= 0.13) and in a few cases moderate (eta 2G <= 0.165). Conclusion: The findings highlight that the MVC calibration approach can reliably be replaced by the SVC approach when the true MVC exertion is not accessible due to pain, kinesiophobia and/or the lack of proper training.
引用
收藏
页数:9
相关论文
共 43 条
  • [1] An EMG-driven musculoskeletal model of the shoulder
    Nikooyan, A. A.
    Veeger, H. E. J.
    Westerhoff, P.
    Bolsterlee, B.
    Graichen, F.
    Bergmann, G.
    van der Helm, F. C. T.
    HUMAN MOVEMENT SCIENCE, 2012, 31 (02) : 429 - 447
  • [2] An EMG-Driven Musculoskeletal Model for Estimating Continuous Wrist Motion
    Zhao, Yihui
    Zhang, Zhiqiang
    Li, Zhenhong
    Yang, Zhixin
    Dehghani-Sanij, Abbas A.
    Xie, Shengquan
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2020, 28 (12) : 3113 - 3120
  • [3] Validation of an EMG-driven, graphically based isometric musculoskeletal model of the cervical spine
    Netto, Kevin J.
    Burnett, Angus F.
    Green, Jonathon P.
    Rodrigues, Julian P.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2008, 130 (03):
  • [4] An Improved Calibration Method of EMG-driven Musculoskeletal Model for Estimating Wrist Joint Angles
    Zhao, Jiamin
    Yu, Yang
    Sheng, Xinjun
    Zhu, Xiangyang
    INTELLIGENT ROBOTICS AND APPLICATIONS, 2020, 12595 : 41 - 51
  • [5] A real-time EMG-driven musculoskeletal model of the ankle
    Manal, Kurt
    Gravare-Silbernagel, Karin
    Buchanan, Thomas S.
    MULTIBODY SYSTEM DYNAMICS, 2012, 28 (1-2) : 169 - 180
  • [6] EMG-Driven Musculoskeletal Model Calibration With Wrapping Surface Personalization
    Ao, Di
    Li, Geng
    Shourijeh, Mohammad S.
    Patten, Carolynn
    Fregly, Benjamin J.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2023, 31 : 4235 - 4244
  • [7] An EMG-driven biomechanical model of the canine cervical spine
    Alizadeh, M.
    Knapik, G. G.
    Dufour, J. S.
    Zindl, C.
    Allen, M. J.
    Bertran, J.
    Fitzpatrick, N.
    Marras, W. S.
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2017, 32 : 101 - 109
  • [8] An EMG-driven Musculoskeletal Model for the Estimation of Biomechanical Parameters of Wrist Flexors
    Colacino, Francesco M.
    Rustighi, Emiliano
    Mace, Brian R.
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 4870 - 4873
  • [9] Computationally Efficient Personalized EMG-Driven Musculoskeletal Model of Wrist Joint
    Zhao, Yihui
    Zhang, Jie
    Li, Zhenhong
    Qian, Kun
    Xie, Sheng Quan
    Lu, Yu
    Zhang, Zhi-Qiang
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [10] Computationally Efficient Personalized EMG-Driven Musculoskeletal Model of Wrist Joint
    Zhao, Yihui
    Zhang, Jie
    Li, Zhenhong
    Qian, Kun
    Xie, Sheng Quan
    Lu, Yu
    Zhang, Zhi-Qiang
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72