The value of 3D T2-weighted SPACE sequence in the differential diagnosis of spinal arteriovenous fistula and acute transverse myelitis

被引:2
作者
Ouyang, Feng [1 ]
Wu, Qin [1 ]
Chen, Ye [1 ]
Yin, Mingxue [1 ]
Liu, Jie [1 ]
Lv, Lianjiang [1 ]
Xu, Zihe [1 ]
Yuan, Xiaoru [1 ]
Zeng, Xianjun [1 ]
机构
[1] Nanchang Univ, Affiliated Hosp 1, Jiangxi Inst Med Imaging, Dept Radiol, 17 Yongwai Zheng St, Nanchang 330006, Jiangxi, Peoples R China
关键词
Spinal arteriovenous fistula; Acute transverse myelitis; Magnetic resonance imaging; Differential diagnosis; IMAGING FEATURES; UTILITY;
D O I
10.1007/s00586-023-07969-x
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
ObjectiveSpinal arteriovenous fistulas (SAVF) was often neglected and misdiagnosed as acute transverse myelitis (ATM) due to its insidious onset and non-specific clinical symptoms. This study aims to investigate the differential diagnostic value of high-resolution T2-weighted volumetric sequence (3D sampling perfection with application-optimized contrasts using different flip-angle evolutions [SPACE]) in patients with SAVF and ATM.MethodsRetrospectively analyzed the clinical and radiological findings of 32 SDAVF patients and 32 ATM patients treated at our institutions from May 2018 to January 2023. They all underwent conventional spinal MRI and T2-SPACE examination, compared their performance in identifying lesions, to estimate the value of T2 SPACE sequence in the diagnosis of SAVF and ATM patients.ResultsThe clue of cauda equina area change (CEAC) in conventional MRI and T2-SPACE sequences is specific for the diagnosis of SAVF. The diagnostic model composed of perimedullary flow voids (PFV) and CEAC has good diagnostic performance (AUCMRI = 0.95; AUCSPACE = 0.935). Compared with conventional MRI, the T2-SPACE sequence has a higher detection rate, sensitivity, and negative predictive value for PFV and CEAC in SAVF patients, but lower specificity and positive predictive value. In T2-SPACE images, there are significant differences in the distribution range, quadrant, and maximum diameter of PFV vessels between SAVF and ATM patients. Moreover, T2-SPACE sequence can determine the site of fistula in most SAVF patients preferably, and the inter-rater agreement was good in the assessment of the fistula.ConclusionThe CEAC is a new and useful clue for the diagnosis of thoracolumbar SAVF. And T2-SPACE sequence can more intuitively observe the lesions of SAVF, has good differential diagnostic value for SAVF and ATM patients.
引用
收藏
页码:4111 / 4117
页数:7
相关论文
共 50 条
  • [41] Comprehensive Volumetric Analysis of Mecp2-Null Mouse Model for Rett Syndrome by T2-Weighted 3D Magnetic Resonance Imaging
    Akaba, Yuichi
    Shiohama, Tadashi
    Komaki, Yuji
    Seki, Fumiko
    Ortug, Alpen
    Sawada, Daisuke
    Uchida, Wataru
    Kamagata, Koji
    Shimoji, Keigo
    Aoki, Shigeki
    Takahashi, Satoru
    Suzuki, Takeshi
    Natsume, Jun
    Takahashi, Emi
    Tsujimura, Keita
    FRONTIERS IN NEUROSCIENCE, 2022, 16
  • [42] 3D T2-Weighted Sampling Perfection with Application-Optimized Contrasts Using Different Flip Angle Evolutions (SPACE) and 3D Time-of-Flight (TOF) MR Angiography Fusion Imaging for Occluded Intracranial Arteries
    Ozaki, Saya
    Okamoto, Shigetaka
    Shinohara, Naoki
    JOURNAL OF NEUROENDOVASCULAR THERAPY, 2022, 16 (09) : 452 - 457
  • [43] MR urography (MRU) of non-dilated ureter with diuretic administration: Static fluid 2D FSE T2-weighted versus 3D gadolinium T1-weighted GE excretory MR
    Roy, C.
    Ohana, M.
    Host, Ph.
    Alemann, G.
    Labani, A.
    Wattiez, A.
    Lang, H.
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2014, 1 : 6 - 13
  • [44] Evaluation of the anterior inferior tibiofibular and anterior talofibular ligaments using 2D oblique coronal imaging and 3D isotropic resolution T2-weighted fast spin-echo sequences at 3.0 T: Is there additional diagnostic value?
    Khil, Eun Kyung
    Cha, Jang Gyu
    Lee, Young Koo
    Kim, Hyun-Joo
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2020, 64 (03) : 338 - 346
  • [45] Single-Slab 3D Fast Spin Echo and Its Variants With Very Long Echo Trains for Clinical T2-Weighted Contrast
    Park, Jaeseok
    INVESTIGATIVE MAGNETIC RESONANCE IMAGING, 2023, 27 (04) : 167 - 181
  • [46] Comparison between 2D FSE T2-weighted Dixon MRI and contrast-enhanced 2D FSE and 3D FSPGR T1-weighted Dixon MRI to quantify inflammation in hands of patients with early rheumatoid arthritis
    Dion, Brice
    Lacrosse, Romain
    Michoux, Nicolas
    Stoenoiu, Maria
    Durez, Patrick
    Lecouvet, Frederic
    Kirchgesner, Thomas
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2023, 104 (7-8) : 351 - 358
  • [47] The value of diffusion tensor imaging in the differential diagnosis of subcortical ischemic vascular dementia and Alzheimer's disease in patients with only mild white matter alterations on T2-weighted images
    Fu, Jian-Liang
    Zhang, Ting
    Chang, Cheng
    Zhang, Yu-Zhen
    Li, Wen-Bin
    ACTA RADIOLOGICA, 2012, 53 (03) : 312 - 317
  • [48] Comparison between postcontrast thin-slice T1-weighted 2D spin echo and 3D T1-weighted SPACE sequences in the detection of brain metastases at 1.5 and 3 T
    Vymazal, Josef
    Ryznarova, Zuzana
    Rulseh, Aaron M.
    INSIGHTS INTO IMAGING, 2024, 15 (01)
  • [49] Comparison between postcontrast thin-slice T1-weighted 2D spin echo and 3D T1-weighted SPACE sequences in the detection of brain metastases at 1.5 and 3 T
    Josef Vymazal
    Zuzana Ryznarova
    Aaron M. Rulseh
    Insights into Imaging, 15
  • [50] Diagnostic value of 3D T1-weighted gradient-echo and 2D T1-weighted in-phase and out-of-phase gradient-echo sequences for appendicitis diagnosis in pregnant women
    Hung, Nguyen Duy
    Dung, Le Thanh
    Dung, Nguyen-Thi Kim
    Ha Khuong, Nguyen
    Anh, Nguyen Hai
    Duc, Nguyen Minh
    JOURNAL OF CLINICAL IMAGING SCIENCE, 2023, 13 : 1 - 6