The value of 3D T2-weighted SPACE sequence in the differential diagnosis of spinal arteriovenous fistula and acute transverse myelitis

被引:2
作者
Ouyang, Feng [1 ]
Wu, Qin [1 ]
Chen, Ye [1 ]
Yin, Mingxue [1 ]
Liu, Jie [1 ]
Lv, Lianjiang [1 ]
Xu, Zihe [1 ]
Yuan, Xiaoru [1 ]
Zeng, Xianjun [1 ]
机构
[1] Nanchang Univ, Affiliated Hosp 1, Jiangxi Inst Med Imaging, Dept Radiol, 17 Yongwai Zheng St, Nanchang 330006, Jiangxi, Peoples R China
关键词
Spinal arteriovenous fistula; Acute transverse myelitis; Magnetic resonance imaging; Differential diagnosis; IMAGING FEATURES; UTILITY;
D O I
10.1007/s00586-023-07969-x
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
ObjectiveSpinal arteriovenous fistulas (SAVF) was often neglected and misdiagnosed as acute transverse myelitis (ATM) due to its insidious onset and non-specific clinical symptoms. This study aims to investigate the differential diagnostic value of high-resolution T2-weighted volumetric sequence (3D sampling perfection with application-optimized contrasts using different flip-angle evolutions [SPACE]) in patients with SAVF and ATM.MethodsRetrospectively analyzed the clinical and radiological findings of 32 SDAVF patients and 32 ATM patients treated at our institutions from May 2018 to January 2023. They all underwent conventional spinal MRI and T2-SPACE examination, compared their performance in identifying lesions, to estimate the value of T2 SPACE sequence in the diagnosis of SAVF and ATM patients.ResultsThe clue of cauda equina area change (CEAC) in conventional MRI and T2-SPACE sequences is specific for the diagnosis of SAVF. The diagnostic model composed of perimedullary flow voids (PFV) and CEAC has good diagnostic performance (AUCMRI = 0.95; AUCSPACE = 0.935). Compared with conventional MRI, the T2-SPACE sequence has a higher detection rate, sensitivity, and negative predictive value for PFV and CEAC in SAVF patients, but lower specificity and positive predictive value. In T2-SPACE images, there are significant differences in the distribution range, quadrant, and maximum diameter of PFV vessels between SAVF and ATM patients. Moreover, T2-SPACE sequence can determine the site of fistula in most SAVF patients preferably, and the inter-rater agreement was good in the assessment of the fistula.ConclusionThe CEAC is a new and useful clue for the diagnosis of thoracolumbar SAVF. And T2-SPACE sequence can more intuitively observe the lesions of SAVF, has good differential diagnostic value for SAVF and ATM patients.
引用
收藏
页码:4111 / 4117
页数:7
相关论文
共 50 条
  • [1] The value of 3D T2-weighted SPACE sequence in the differential diagnosis of spinal arteriovenous fistula and acute transverse myelitis
    Feng Ouyang
    Qin Wu
    Ye Chen
    Mingxue Yin
    Jie Liu
    Lianjiang Lv
    Zihe Xu
    Xiaoru Yuan
    Xianjun Zeng
    European Spine Journal, 2023, 32 : 4111 - 4117
  • [2] Diagnosis of spinal dural arteriovenous fistula using 3D T2-weighted imaging
    Kralik, Stephen F.
    Murph, Daniel
    Mehta, Peter
    O'Neill, Darren P.
    NEURORADIOLOGY, 2017, 59 (10) : 997 - 1002
  • [3] Utility of T2-weighted MRI and contrast-enhanced MRA in locating the fistula level of spinal arteriovenous fistula
    Ouyang, Feng
    Wu, Qin
    Yan, Meimei
    Chen, Jialu
    Luo, Zhijun
    Pan, Laisheng
    Wang, Bo
    Zhou, Fuqing
    Zeng, Xianjun
    EUROPEAN SPINE JOURNAL, 2025, 34 (03) : 853 - 860
  • [4] A comparison study between 3D T2-weighted SPACE and conventional 2D T2-weighted turbo spin echo in assessment of carotid plaque
    Lv, Peng
    Dai, Yuanyuan
    Lin, Jiang
    Zhang, Weisheng
    Liu, Hao
    Liu, Hui
    Tang, Xiao
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (03) : 395 - 400
  • [5] A comparison study between 3D T2-weighted SPACE and conventional 2D T2-weighted turbo spin echo in assessment of carotid plaque
    Peng Lv
    Yuanyuan Dai
    Jiang Lin
    Weisheng Zhang
    Hao Liu
    Hui Liu
    Xiao Tang
    The International Journal of Cardiovascular Imaging, 2017, 33 : 395 - 400
  • [6] 3D T2-Weighted Spin Echo Imaging in the Breast
    Moran, Catherine J.
    Hargreaves, Brian A.
    Saranathan, Manojkumar
    Lipson, Jafi A.
    Kao, Jennifer
    Ikeda, Debra M.
    Daniel, Bruce L.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (02) : 332 - 338
  • [7] Diagnostic performance of heavily T2-weighted techniques in obstructive hydrocephalus: comparison study of two different 3D heavily T2-weighted and conventional T2-weighted sequences
    Murat Ucar
    Nil Tokgoz
    Cagri Damar
    Ayse Gul Alimli
    Fatih Oncu
    Japanese Journal of Radiology, 2015, 33 : 94 - 101
  • [8] Diagnostic performance of heavily T2-weighted techniques in obstructive hydrocephalus: comparison study of two different 3D heavily T2-weighted and conventional T2-weighted sequences
    Ucar, Murat
    Tokgoz, Nil
    Damar, Cagri
    Alimli, Ayse Gul
    Oncu, Fatih
    JAPANESE JOURNAL OF RADIOLOGY, 2015, 33 (02) : 94 - 101
  • [9] Relative quantification of signal on T2-weighted images in the basal ganglia: Limited value in differential diagnosis of patients with parkinsonism
    Schwarz J.
    Kraft E.
    Vogl T.
    Arnold G.
    Tatsch K.
    Oertel W.H.
    Neuroradiology, 1999, 41 (2) : 124 - 128
  • [10] Visual assessment of cerebrospinal fluid flow dynamics using 3D T2-weighted SPACE sequence-based classification system
    Naldemir, Ibrahim Feyyaz
    Karaman, Ahmet Kursat
    Ogul, Hayri
    Onbas, Omer
    ACTA RADIOLOGICA, 2024, 65 (12) : 1576 - 1582