Quality assurance for mixed electron-photon beam radiation therapy using treatment log files and MapCHECK

被引:0
作者
Tai, Yee Man [1 ,7 ]
Heng, Veng Jean [2 ]
Renaud, Marc-Andre [3 ]
Serban, Monica [4 ,5 ]
Seuntjens, Jan [4 ,5 ,6 ]
机构
[1] McGill Univ, Med Phys Unit, Montreal, PQ, Canada
[2] McGill Univ, Dept Phys & Med Phys Unit, Montreal, PQ, Canada
[3] Gray Oncol Solut, Montreal, PQ, Canada
[4] Univ Toronto, Princess Margaret Canc Ctr, Toronto, ON, Canada
[5] Univ Toronto, Dept Radiat Oncol, Toronto, ON, Canada
[6] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
[7] 1001 Blvd Decarie Rm DS1-502, Montreal, PQ H4A 3J1, Canada
关键词
MapCHECK; mixed-beam therapy; quality assurance; VOLUMETRIC-MODULATED ARC; IMRT; ENERGY; OPTIMIZATION;
D O I
10.1002/mp.16759
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundMixed photon-electron beam radiotherapy (MBRT) is a technique that combines the use of both photons and electrons in one single treatment plan to exploit their advantageous and complimentary characteristics. Compared to other photon treatment modalities, it has been shown that the MBRT technique contributes to better target coverage and organ-at-risk (OAR) sparing. However, the use of combined photons and electrons in one delivery makes the technique more complex and a well-established quality assurance (QA) protocol for MBRT is essential.PurposeTo investigate the feasibility of using MapCHECK and log file-dose reconstruction for MBRT plan verification and to recommend a patient-specific quality assurance (PSQA) protocol for MBRT.MethodsMBRT plans were robustly optimized for five soft-tissue sarcoma (STS) patients. Each plan comprised step-and-shoot deliveries of a six MV photon beam and a combination of five electron beam energies at an SAD of 100 cm. The plans were delivered to the MapCHECK device with collapsed gantry angle and the 2D dose distributions at the detector depth were measured. To simulate the expected dose distribution delivered to the MapCHECK, a MapCHECK computational phantom was modeled in EGSnrc based on vendor-supplied blueprint information. The dose to the detectors in the model was scored using the DOSXYZnrc user code. The agreement between the measured and the simulated dose distribution was evaluated using 2D gamma analysis with a gamma criterion of 3%/2 mm and a low dose threshold of 10%. One of the plans was selected and delivered with a rotating gantry angle for trajectory log file collection. To evaluate the potential interlinac and intralinac differences, the plan was delivered repeatedly on three linacs. From the collected log files, delivery parameters were retrieved to recalculate the 3D dose distributions in the patient's anatomy with DOSXYZnrc. The recalculated mean dose to the clinical target volume (CTV) and OARs from all deliveries were computed and compared with the planned dose in terms of percentage difference. To validate the accuracy of log file-based QA, the log file-recalculated dose was also compared with film measurement.ResultsThe agreement of the total dose distribution between the MapCHECK measurement and simulation showed gamma passing rates of above 97% for all five MBRT plans. In the log file-dose recalculation, the difference between the recalculated and the planned dose to the CTV and OARs was below 1% for all deliveries. No significant inter- or intralinac differences were observed. The log file-dose had a gamma passing rate of 98.6% compared to film measurement.ConclusionBoth the MapCHECK measurements and log file-dose recalculations showed excellent agreement with the expected dose distribution. This study demonstrates the potential of using MapCHECK and log files as MBRT QA tools.
引用
收藏
页码:7996 / 8008
页数:13
相关论文
共 29 条
  • [1] Monte Carlo based modulated electron beam treatment planning using a few-leaf electron collimator - feasibility study
    Al-Yahya, K
    Hristov, D
    Verhaegen, F
    Seuntjens, J
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (05) : 847 - 857
  • [2] Direct aperture optimization for FLEC-based MERT and its application in mixed beam radiotherapy
    Alexander, Andrew
    Soisson, Emilie
    Renaud, Marc-Andre
    Seuntjens, Jan
    [J]. MEDICAL PHYSICS, 2012, 39 (08) : 4820 - 4831
  • [3] Multileaf collimation of electrons-clinical effects on electron energy modulation and mixed beam therapy depending on treatment head design
    Blomquist, M
    Karlsson, MG
    Zackrisson, B
    Karlsson, M
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (07) : 1013 - 1024
  • [4] IMRT: a review and preview
    Bortfeld, Thomas
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (13) : R363 - R379
  • [5] Delivery validation of an automated modulated electron radiotherapy plan
    Connell, T.
    Alexander, A.
    Papaconstadopoulos, P.
    Serban, M.
    Devic, S.
    Seuntjens, J.
    [J]. MEDICAL PHYSICS, 2014, 41 (06)
  • [6] Anatomy-based, patient-specific VMAT QA using EPID or MLC log files
    Defoor, Dewayne L.
    Vazquez-Quino, Luis A.
    Mavroidis, Panayiotis
    Papanikolaou, Nikos
    Stathakis, Sotirios
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (03): : 206 - 215
  • [7] RapidArc quality assurance through MapCHECK
    Gloi, Aime M.
    Buchanan, Robert E.
    Zuge, Corrie L.
    Goettler, AnnDrea M.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (02): : 39 - 47
  • [8] Implementation and experimental validation of a robust hybrid direct aperture optimization approach for mixed-beam radiotherapy
    Heath, Emily
    Mueller, Silvan
    Guyer, Gian
    Duetschler, Alisha
    Elicin, Olgun
    Aebersold, Daniel
    Fix, Michael K.
    Manser, Peter
    [J]. MEDICAL PHYSICS, 2021, 48 (11) : 7299 - 7312
  • [9] Ion chamber and film-based quality assurance of mixed electron-photon radiation therapy
    Heng, Veng Jean
    Serban, Monica
    Seuntjens, Jan
    Renaud, Marc-Andre
    [J]. MEDICAL PHYSICS, 2021, 48 (09) : 5382 - 5395
  • [10] Radiotherapy of breast cancer after breast-conserving surgery:: an improved technique using mixed electron-photon beams with a multileaf collimator
    Jansson, T
    Lindman, H
    Nygård, K
    Dahlgren, CV
    Montelius, A
    Öberg-Kreuger, C
    Asplund, S
    Bergh, J
    [J]. RADIOTHERAPY AND ONCOLOGY, 1998, 46 (01) : 83 - 89