A mid-IR laser diagnostic for HCN detection

被引:9
|
作者
Elkhazraji, Ali [1 ]
Adil, Mohammad [1 ]
Mhanna, Mhanna [1 ]
Abualsaud, Nawaf [1 ]
Alsulami, Ahmed Ayidh [1 ]
Shakfa, Mohammad Khaled [1 ]
Marangoni, Marco [2 ,3 ]
Giri, Binod [1 ]
Farooq, Aamir [1 ]
机构
[1] King Abdullah Univ Sci & Technol KAUST, Clean Combust Res Ctr, Phys Sci & Engn Div, Thuwal 239556900, Saudi Arabia
[2] Politecn Milan, Dipartimento Fis, Via Gaetano Previati 1-C, I-23900 Lecce, Italy
[3] CNR, IFN, Via Gaetano Previati 1-C, I-23900 Lecce, Italy
关键词
HCN; Isoxazole decomposition; Absorption cross-section; Shock tube; Difference -frequency generation; HYDROGEN-CYANIDE; SHOCK-TUBE; NITROUS-OXIDE; NITRIC-OXIDE; COMBUSTION; ABSORPTION; EMISSIONS; BAND; OXIDATION;
D O I
10.1016/j.proci.2022.09.054
中图分类号
O414.1 [热力学];
学科分类号
摘要
Hydrogen cyanide (HCN) is a major source of prompt-NO x formation especially in fuel-bound nitrogen systems. To date, there is still a significant disagreement between experimental data and theoretical predictions of the rate coefficients of combustion reactions involving HCN as a prompt-NO x precursor. Accurate modeling of NO x formation would greatly benefit from a diagnostic capable of performing high-fidelity measurements of HCN formation/consumption time-histories. In this study, a laser diagnostic is developed for sensitive and selective HCN sensing by probing its most intense absorption feature in the mid-infrared (MIR). The diagnostic is based on difference-frequency generation (DFG) between a CO 2 gas laser and an external-cavity quantum cascade laser in a nonlinear orientation-patterned gallium arsenide crystal which results in a DFG laser tunable over 11.56 - 15 & mu;m. HCN measurements were carried out at the peak of the Q -branch of its strong & nu;2 vibrational band near 14 & mu;m. Pressure dependence of the absorption cross-section was investigated at room temperature over the pressure range of 0.07 - 1.07 bar. Temperature-dependent absorption cross-section measurements were conducted behind reflected shock waves over the temperature range of 850 - 3000 K. The diagnostic was demonstrated in reactive experiments in a shock tube where HCN mole fraction time-histories were measured during the thermal decomposition of isoxazole (C 3 H 3 NO) and the first-order rate coefficients of C 3 H 3 NO & RARR; HCN + CH 2 CO reaction were determined. & COPY; 2022 The Combustion Institute. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1485 / 1493
页数:9
相关论文
共 50 条
  • [1] Dynamics of an Erbium Mid-IR Laser
    Bowman, Steven R.
    Condon, Nicholas J.
    O'Connor, Shawn
    2010 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO) AND QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (QELS), 2010,
  • [2] Interference-free mid-IR laser absorption detection of methane
    Pyun, Sung Hyun
    Cho, Jungwan
    Davidson, David F.
    Hanson, Ronald K.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2011, 22 (02)
  • [3] A mid-infrared laser diagnostic for simultaneous detection of furan and nitric oxide
    Elkhazraji, Ali
    Sy, Mohamed
    Shakfa, Mohammad Khaled
    Farooq, Aamir
    PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2024, 40 (1-4)
  • [4] MID-IR laser absorption spectroscopy of 1-and 2-butanol in a shock tube facility
    Agarwal, Sumit
    Sane, Laxmi
    Fernandes, Ravi X.
    Shu, Bo
    COMBUSTION AND FLAME, 2022, 243
  • [5] Quantification of Elevated Hydrogen Cyanide (HCN) Concentration Typical in a Residential Fire Environment Using Mid-IR Tunable Diode Laser
    Ghanekar, Shruti
    Horn, Gavin P.
    Kesler, Richard M.
    Rajasegar, Rajavasanth
    Yoo, Jihyung
    Lee, Tonghun
    APPLIED SPECTROSCOPY, 2023, 77 (04) : 382 - 392
  • [6] Mid-IR Photothermal Spectroscopy with an Integrated Fiber Probe Laser
    Sander, Michelle Y.
    Liu, Hui
    Mertiri, Alket
    Totachawattana, Atcha
    Erramilli, Shyamsunder
    2014 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2014,
  • [7] A mid-IR laser absorption diagnostic for measuring formaldehyde at high pressures and its demonstration in shock tubes
    Biswas, Pujan
    Choudhary, Rishav
    Panda, Alka
    Davidson, David F.
    Hanson, Ronald K.
    COMBUSTION AND FLAME, 2022, 245
  • [8] A mid-infrared diagnostic for benzene using a tunable difference-frequency-generation laser
    Shakfa, Mohammad Khaled
    Mhanna, Mhanna
    Jin, Hanfeng
    Liu, Dapeng
    Djebbi, Khalil
    Marangoni, Marco
    Farooq, Aamir
    PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2021, 38 (01) : 1787 - 1796
  • [9] Mid-IR Photothermal Imaging with a Compact Ultrafast Fiber Probe Laser
    Liu, Hui
    Totachawattana, Atcha
    Mertiri, Alket
    Hong, Mi K.
    Gardner, Tim
    Erramilli, Shyamsunder
    Sander, Michelle Y.
    ULTRAFAST NONLINEAR IMAGING AND SPECTROSCOPY II, 2014, 9198
  • [10] Compact optical scheme for the generation of ultrafast mid-IR laser pulses
    Rajput, Vinod K.
    Jana, Prasenjit
    Ponnan, Sajin
    Abu Taher, Md
    Naraharisetty, Sri Ram G.
    PRAMANA-JOURNAL OF PHYSICS, 2022, 96 (04):