Radiographic Analysis in Extra-Articular and Intra-Articular Distal Radius Fractures Treated with Variable-Angle Volar Locking Plate Fixation

被引:2
作者
Fang, Pin-Chieh [1 ]
Lo, Tak-Yu-Yubie [1 ]
Cheng, Chun-Ying [2 ,3 ]
Wu, Chun-Te [4 ]
Chen, Alvin Chao-Yu [2 ,3 ]
机构
[1] Chang Gung Univ, Chang Gung Mem Hosp Linkou, Coll Med, Taoyuan 33305, Taiwan
[2] Chang Gung Univ, Chang Gung Mem Hosp Linkou, Coll Med, Bone & Joint Res Ctr,Dept Orthopaed Surg, Taoyuan 33305, Taiwan
[3] Chang Gung Univ, Chang Gung Mem Hosp Taoyuan, Coll Med, Comprehens Sports Med Ctr, Taoyuan 33305, Taiwan
[4] Chang Gung Univ, Chang Gung Mem Hosp Linkou, Coll Med, Dept Med Imaging & Intervent, Taoyuan 33305, Taiwan
关键词
distal radius fracture; variable-angle volar locking plate; radiographic parameters; RELIABILITY; REMOVAL;
D O I
10.3390/jcm12103494
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
(1) Background: Different distal radial fracture types have different prognosis after fixation. Our study aim is to evaluate the differences in radiographic parameters by using variable-angle volar locking plate (VAVLP) fixation according to extra-articular and intra-articular distal radial fracture. (2) Methods: There are two groups: extra-articular group (21) and intra-articular group (25). Forearm radiographs immediately after surgery and at 3 months after operation were reviewed for analyzing radial height (RH), ulnar variance (UV), radial inclination (RI), volar tilt (VT), tear drop angle (TDA), distal dorsal cortical distance (DDD), and Soong classification (SC). (3) Results: There were no significant differences in the above parameters between two groups at either immediately post-operative or at 3-month follow-up, except for TDA (p = 0.048). Most patients in both groups were at low risk of flexor tendon rupture, except for two cases. We observed a positive correlation between post-operative DDD and 3-month change in the intra-articular group, but not the extra-articular group. (4) Conclusions: Our study demonstrates that VAVLP fixation is effective in maintaining the stability of most radiographic parameters and reduces the risk of tendon rupture in both extra-articular and intra-articular distal radial fractures. Post-operative DDD can be used to predict the degree of subsequent displacement in patients with intra-articular fractures fixed with VAVLP.
引用
收藏
页数:11
相关论文
共 28 条
[1]   Classification of distal radius fractures: An analysis of interobserver reliability and intraobserver reproducibility [J].
Andersen, DJ ;
Blair, WF ;
Steyers, CM ;
Adams, BD ;
ElKhouri, GY ;
Brandser, EA .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1996, 21A (04) :574-582
[2]  
Bozentka DJ, 2002, CLIN ORTHOP RELAT R, P409
[3]   Early Results of a Variable-Angle Volar Locking Plate for Distal Radius Fractures: A Bi-centre Study [J].
Elerian, Sherif ;
Singh, Talvinder ;
Jagodzinsk, Nikolas A. ;
Norris, Rory ;
Tan, Simon ;
Power, Dominic ;
Jones, Jonathan ;
Chen, Zehong ;
Eltagy, Hassan .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (09)
[4]   Comparison of volarly and dorsally displaced distal radius fracture treated by volar locking plate fixation [J].
Erhart, S. ;
Toth, S. ;
Kaiser, P. ;
Kastenberger, T. ;
Deml, C. ;
Arora, R. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (06) :879-885
[5]  
Fang P.C., 2021, FORMOS J MUSCULOSKEL, V12, P43, DOI [10.6492/fjmd.202105_12(2).0001, DOI 10.6492/FJMD.202105_12(2).0001]
[6]  
Forward D., 2011, ORTHOP PROC, V93-B, P6, DOI [10.1302/0301-620X.93BSUPP_I.0930006d, DOI 10.1302/0301-620X.93BSUPP_I.0930006D]
[7]   Reliability and Clinical Importance of Teardrop Angle Measurement in Intra-articular Distal Radius Fracture [J].
Fujitani, Ryotaro ;
Omokawa, Shohei ;
Iida, Akio ;
Santo, Shigeru ;
Tanaka, Yasuhito .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2012, 37A (03) :454-459
[8]   Impact of Soong grading on flexor tendon ruptures following palmar plating for distal radial fractures [J].
Goeren, Yekta ;
Sauerbier, Michael ;
Arsalan-Werner, Annika .
JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2020, 45 (04) :348-353
[9]  
Gogna Paritosh, 2013, ISRN Orthop, V2013, P131757, DOI 10.1155/2013/131757
[10]  
Hart A, 2015, J ORTHOP TRAUMA, V29, pE1, DOI 10.1097/BOT.0000000000000146