共 35 条
Application of multi-spectral CT imaging in Crohn's disease: a systematic review
被引:2
作者:
Grassi, Giovanni
[1
,10
]
Laino, Maria Elena
[1
,2
]
Kalra, Mannudeep
[3
]
Cherchi, Maria Valeria
[1
]
Nicola, Refky
[4
]
Mannelli, Lorenzo
[5
]
Balestrieri, Antonella
[1
]
Suri, Jasjit S.
[6
,7
,8
]
Sala, Evis
[9
]
Saba, Luca
[1
]
机构:
[1] Azienda Osped Univ AOU, Dept Radiol, Cagliari, Italy
[2] IRCSS Human Res Hosp, Artificial Intelligence Ctr, Milan, Italy
[3] Harvard Med Sch, Massachusetts Gen Hosp, Dept Radiol, Boston, MA USA
[4] Roswell Park Canc Inst, Jacobs Sch Med & Biomed Sci, Dept Radiol, Buffalo, NY USA
[5] IRCCS SDN, Dept Radiol, Naples, Italy
[6] AtheroPoint, Diagnost & Monitoring Div, Roseville, CA USA
[7] Global Biomed Technol Inc, Knowledge Engn Ctr, Roseville, CA USA
[8] Idaho State Univ, Dept Elect & Comp Engn, Pocatello, ID USA
[9] Univ Cambridge, Dept Radiol, Cambridge, England
[10] Azienda Osped Univ AOU Cagliari Polo Monserrato, Dept Radiol, SS 554, I-09045 Cagliari, Italy
关键词:
Computed tomography;
dual-energy computed tomography;
iodine quantification;
iodine concentration;
Crohn's disease;
ENERGY-COMPUTED-TOMOGRAPHY;
IODINE DENSITY;
ENTEROGRAPHY;
QUALITY;
PATIENT;
MAPS;
QUANTIFICATION;
ACQUISITION;
ACCURACY;
ABDOMEN;
D O I:
10.1177/02841851231170849
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Background No quantitative computed tomography (CT) biomarker is actually sufficiently accurate to assess Crohn's disease (CD) lesion activity, with adequate precision to guide clinical decisions. Purpose To assess the available literature on the use of iodine concentration (IC), from multi-spectral CT acquisition, as a quantitative parameter able to distinguish healthy from affected bowel and assess CD bowel activity and heterogeneity of activity along the involved segments. Material and Methods A literature search was conducted to identify original research studies published up to February 2022. The inclusion criteria were original research papers (>10 human participants), English language publications, focus on dual-energy CT (DECT) of CD with iodine quantification (IQ) as an outcome measure. The exclusion criteria were animal-only studies, languages other than English, review articles, case reports, correspondence, and study populations Results Nine studies were included in this review; all of which showed a strong correlation between IC measurements and CD activity markers, such as CD activity index (CDAI), endoscopy findings and simple endoscopic score for Crohn's disease (SES-CD), and routine CT enterography (CTE) signs and histopathologic score. Statistically significant differences in IC were reported between affected bowel segments and healthy ones (higher P value was P < 0.001), normal segments and those with active inflammation (P < 0.0001) as well as between patients with active disease and those in remission (P < 0.001). Conclusion The mean normalized IC at DECTE could be a reliable tool in assisting radiologists in the diagnosis, classification and grading of CD activity.
引用
收藏
页码:2347 / 2356
页数:10
相关论文