Multi-channel Small Animal Drug Metabolism Real-Time Monitoring Fluorescence System

被引:1
作者
Li, Yiran [1 ]
Jin, Xiaofei [1 ]
Wang, Feilong [1 ]
Zhou, Huijing [1 ]
Gu, Yueqing [2 ]
Yang, Yamin [1 ]
Qian, Zhiyu [1 ]
Li, Weitao [1 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Automat Engn, Dept Biomed Engn, Nanjing 211106, Peoples R China
[2] China Pharmaceut Univ, Engn Coll, Nanjing 211198, Peoples R China
关键词
Fluorescence; Pharmacokinetic; Multi-organization; In vivo; Real time; RETROSPECTIVE ANALYSIS; TISSUE DISTRIBUTION; PHARMACOKINETICS; PRINCIPLES; SOFTWARE; PHARMACODYNAMICS; EXCRETION; DESIGN;
D O I
10.1007/s11307-023-01883-w
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The data acquisition of drug metabolism analysis requires a lot of time and animal resources. However, there are often many deviations in the results of pharmacokinetic analysis. Conventional methods cannot measure the blood drug concentration data in multiple tissues at the same time, and the data is obtained by in vitro measurement, which produces time errors, in vitro data errors, and individual differences between animals. In the analysis of pharmacokinetic parameters, it will seriously affect the pass rate of clinical trials of R&D drugs and the accuracy of the dosing schedule. To the best of our knowledge, we have not found the study of in vivo blood drug concentration using multi-channel equipment. Therefore, the purpose of this paper is to build a set of multi-organ monitoring and analysis instruments for synchronously monitoring the metabolism of drugs in various tissues of small animals, so as to obtain real in vivo data of blood drug concentration in real time.Procedures: Using the fluorescence properties and laser-induced fluorescence principle of drugs, we designed six channels to monitor the changes of fluorescence-labeled drugs in their main metabolic organs, a multi-channel calibration method was proposed to improve the accuracy of the time-division multiplexing, the real-time collection of drug concentration in vivo is realized, and the drug metabolism curve in vivo can be observed.Results: The instrument satisfies the collection of small doses of drugs such as microgram; the detection sensitivity can reach 10 ng/ml, and can monitor and collect the drug metabolism of multiple small animal tissues at the same time, which greatly reduces the use of animals, reduces the differences between individuals, and reduces consumption cost and improve the detection efficiency of parameters, and obtain data information that is closer to the real biology.Conclusion: The real-time continuous monitoring and data collection of the drug metabolism in the plasma of living small animals and the important organs such as kidney, liver, and spleen were realized. The research and development of new drugs and clinical research have higher practical value.
引用
收藏
页码:138 / 147
页数:10
相关论文
共 50 条
  • [31] A real-time photoacoustic tomography system for small animals
    Gamelin, John
    Maurudis, Anastasios
    Aguirre, Andres
    Huang, Fei
    Guo, Puyun
    Wang, Lihong V.
    Zhu, Quing
    OPTICS EXPRESS, 2009, 17 (13): : 10489 - 10498
  • [32] An embedded multi-sensor system on the rotating dynamometer for real-time condition monitoring in milling
    Rizal, Muhammad
    Ghani, Jaharah A.
    Nuawi, Mohd Zaki
    Haron, Che Hassan Che
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2018, 95 (1-4) : 811 - 823
  • [33] Real-time True-color Volume Visualization of Multi-channel 3D CLSM Images Based on CUDA
    Dai, Yakang
    Zhang, Yunhai
    Zhou, Zhiyong
    Yang, Haomin
    Xue, Xiaojun
    PROCEEDINGS IWBBIO 2014: INTERNATIONAL WORK-CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1 AND 2, 2014, : 1686 - 1693
  • [34] Fluorescence-Shadowing Nanoparticle Clusters for Real-Time Monitoring of Tumor Progression
    Pham-Nguyen, Oanh-Vu
    Shin, JiUn
    Park, Yeonju
    Jin, Sila
    Kim, Song Rae
    Jung, Young Mee
    Yoo, Hyuk Sang
    BIOMACROMOLECULES, 2022, 23 (08) : 3130 - 3141
  • [35] Real-time remote monitoring system for aquaculture water quality
    Luo Hongpin
    Li Guanglin
    Peng Weifeng
    Song Jie
    Bai Qiuwei
    INTERNATIONAL JOURNAL OF AGRICULTURAL AND BIOLOGICAL ENGINEERING, 2015, 8 (06) : 136 - 143
  • [36] A wearable ECG monitoring system for real-time arrhythmia detection
    Clark, Nicholar
    Sandor, Edward
    Walden, Calvin
    Ahn, In Soo
    Lu, Yufeng
    2018 IEEE 61ST INTERNATIONAL MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS (MWSCAS), 2018, : 787 - 790
  • [37] An LED array-based light induced fluorescence sensor for real-time process and field monitoring
    Dickens, Jason E.
    Vaughn, Michael S.
    Taylor, Mervin
    Ponstingl, Mike
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 158 (01): : 35 - 42
  • [38] Efficient Wearable Real-time Vital Signs Monitoring System
    Abd El Ghany, Mohamed A.
    Saleab, Michael S.
    Toma, Ramez M.
    Hofmann, Klaus
    2015 IEEE CONFERENCE ON ELECTRONICS, CIRCUITS, AND SYSTEMS (ICECS), 2015, : 217 - 220
  • [39] Implementation of a real-time monitoring system with statistical process control
    Lee, KueiJen
    Li, Bin
    2008 PROCEEDINGS OF INFORMATION TECHNOLOGY AND ENVIRONMENTAL SYSTEM SCIENCES: ITESS 2008, VOL 2, 2008, : 843 - 846
  • [40] Design and experiment on real-time monitoring system of wheat seeding
    Lu C.
    Fu W.
    Zhao C.
    Mei H.
    Meng Z.
    Dong J.
    Gao N.
    Wang X.