Effect of different implant angulations on the biomechanical performance of prosthetic screws in two implant-supported, screw-retained prostheses: A numerical and experimental study

被引:3
作者
Chen, Jianyu [1 ]
Guo, Jiaer [1 ]
Yang, Lijia [2 ]
Wang, Lin [1 ,4 ]
Zhang, Xiao [3 ]
机构
[1] Sun Yat Sen Univ, Hosp Stomatol, Guangdong Prov Key Lab Stomatol, Dept Oral Implantol,Guanghua Sch Stomatol, Guangzhou, Peoples R China
[2] Jinan Univ, Coll Stomatol, Guangzhou, Peoples R China
[3] Foshan Angels Biotechnol Co Ltd, Foshan, Peoples R China
[4] Sun Yat Sen Univ, Hosp Stomatol, Guanghua Sch Stomatol, Guangdong Prov Key Lab Stomatol, Guangzhou 510055, Peoples R China
基金
中国国家自然科学基金;
关键词
FIXED DENTAL PROSTHESES; COMPLICATIONS; CANTILEVER; SURVIVAL; CROWNS; CEMENT;
D O I
10.1016/j.prosdent.2023.06.004
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. A mesiodistal angle frequently forms between 2 splinted implant-supported, screw-retained fixed dental prostheses (TIS-FDPs). Mechanical complications commonly occur in prosthetic screws. Studies regarding the effect of the degree of implant angulation on the biomechanical performance of prosthetic screws in TIS-FDPs are sparse.Purpose. The purpose of this numerical and experimental study was to investigate the effects of different implant angulations on the biomechanical performance, including stress distribution, stability of the screw joint, and surface morphology change of the prosthetic screws in TIS-FDPs.Material and methods. TIS-FDPs were classified into 4 groups: 0, 10, 20, and 30 degrees based on the degree of mesiodistal angle between the long axes of the 2 implants. In the finite element analysis (FEA), 4 series of 3D models were constructed and loaded with simulated occlusal forces. The von Mises stresses and rotational angles of the prosthetic screws were then calculated. In the mechanical test, each group of 5 TIS-FDPs with 10 prosthetic screws was tested under 1 million loading cycles by using a universal testing machine. The removal torque values (RTVs) and the surface roughness of the prosthetic screws were measured after cyclic loading. The normality of the outcome variables was assessed by the Shapiro-Wilk test. Analysis of variance and the Kruskal-Wallis test were used for further analysis (& alpha;=.05).Results. The FEA results showed that the von Mises stresses of the prosthetic screws were concentrated in the first screw thread crest engaged with the abutment, and the maximum values of the threads and the rotation angles of the prosthetic screws increased in the 2-implant mesiodistal angulation from 0 to 30 degrees. The mechanical tests showed that the RTVs of the prosthetic screws in each group were not significantly different after 1 million loading cycles (P=.107). The surface roughness of the crest of the first 2 threads of the prosthetic screws in the 30-degree group changed significantly compared with those in the other groups.Conclusions. When TIS-FDPs were delivered, larger angulations of the 2 splinted implants seemed to increase the stress concentrated on the crest of the first engaged thread and the rotation angles of the prosthetic screws. After 1 million loading cycles, significant surface adhesive wear was identified on the crest of the first 2 threads of the prosthetic screws in the 30-degree group compared with groups with a smaller angulation.
引用
收藏
页码:240.e1 / 240.e10
页数:10
相关论文
共 34 条
[1]   Clinical and radiographic changes at implants supporting single-unit crowns (SCs) and fixed dental prostheses (FDPs) with one cantilever extension. A retrospective study [J].
Aglietta, Marco ;
Siciliano, Vincenzo Iorio ;
Blasi, Andrea ;
Sculean, Anton ;
Braegger, Urs ;
Lang, Niklaus P. ;
Salvi, Giovanni E. .
CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (05) :550-555
[2]   A systematic review of the survival and complication rates of implant supported fixed dental prostheses with cantilever extensions after an observation period of at least 5 years [J].
Aglietta, Marco ;
Siciliano, Vincenzo Iorio ;
Zwahlen, Marcel ;
Braegger, Urs ;
Pjetursson, Biarni E. ;
Lang, Niklaus P. ;
Salvi, Giovanni E. .
CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (05) :441-451
[3]  
Al Jabbari Youssef, 2008, J Prosthodont, V17, P181
[4]  
Al Jabbari Youssef S, 2008, J Prosthodont, V17, P168
[5]  
Al Jabbari Youssef S, 2008, J Prosthodont, V17, P192, DOI 10.1111/j.1532-849X.2007.00290.x
[6]  
Al Jabbari Youssef S, 2008, J Prosthodont, V17, P201, DOI 10.1111/j.1532-849X.2007.00291.x
[7]   Biological and technical complications of tilted implants in comparison with straight implants supporting fixed dental prostheses. A systematic review and meta-analysis [J].
Alccayhuaman, Karol Ali Apaza ;
Soto-Penaloza, David ;
Nakajima, Yasushi ;
Papageorgiou, Spyridon N. ;
Botticelli, Daniele ;
Lang, Niklaus P. .
CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 :295-308
[8]   Fatigue performance of prosthetic screws used in dental implant restorations: Rolled versus cut threads [J].
Armentia, Mikel ;
Abasolo, Mikel ;
Coria, Ibai ;
Albizuri, Joseba ;
Aguirrebeitia, Josu .
JOURNAL OF PROSTHETIC DENTISTRY, 2021, 126 (03) :406.e1-406.e8
[9]   The prosthetic screw loosening of two-implant supported screw-retained fixed dental prostheses in the posterior region: A retrospective evaluation and finite element analysis [J].
Chen, Jianyu ;
Wang, Lin ;
Yang, Lijia ;
Zhang, Xiao ;
Huang, Baoxin ;
Li, Jingping .
JOURNAL OF BIOMECHANICS, 2021, 122
[10]  
Cho Sang-Choon, 2004, Implant Dent, V13, P245, DOI 10.1097/01.id.0000140459.87333.f8