Visual Performance of Eyes with Residual Refractive Errors after Implantation of an Extended Vision Intraocular Lens

被引:0
作者
Rementeria-Capelo, Laureano A. A. [1 ]
Contreras, Ines [1 ,2 ,3 ]
Moran, Aida [1 ]
Lorente-Hevia, Pilar [1 ,4 ]
Marinas, Laura [1 ]
Ruiz-Alcocer, Javier [4 ,5 ]
机构
[1] Clin Rementeria, Madrid, Spain
[2] Hosp Univ Ramon & Cajal, Madrid, Spain
[3] Inst Ramon y Cajal Invest Sanit IRYCIS, Madrid, Spain
[4] Univ Complutense Madrid, Opt & Optometry Dept, Madrid, Spain
[5] Univ Complutense Madrid, Clin & Expt Eye Res Grp, UCM 971009, Madrid, Spain
关键词
ACUITY; ASTIGMATISM; DEFOCUS;
D O I
10.1155/2023/7701390
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background. To analyze the tolerance on distance vision of different combined residual astigmatic situations in patients implanted with a novel wavefront shaping extended depth of focus (EDoF) intraocular lens (IOL). Methods. The study included patients implanted with the Acrysof (R) IQ Vivity (R) IOL. Uncorrected (UDVA) and corrected distance visual acuity (CDVA) were measured three months after surgery, considering CDVA as the reference situation of the study. Distance VA was also measured in different refractive situations: (A) with 0.50 diopters (D) of positive (myopization) and negative (hyperopization) defocus and (B) with a residual mixed astigmatic refraction induced by adding a combination of -0.25D spherical and 0.50D cylindrical lenses placed in vertical (against the rule-ATR), oblique, and horizontal (with the rule-WTR) positions. Results. The study included 30 eyes of 30 patients. UDVA and CDVA were -0.04 +/- 0.05 and -0.05 +/- 0.05 logMAR, respectively. VA values with +0.50D and -0.50D of defocus were 0.01 +/- 0.06 and 0.00 +/- 0.04 logMAR, respectively. VA was better with distance correction (p < 0.001) and no differences were found between the myopic and the hyperopic situations (p = 0.09). Distance VA for the ATR, oblique, and WTR astigmatic situations was 0.01 +/- 0.05, 0.01 +/- 0.06, and 0.01 +/- 0.04 logMAR, respectively. VA was better for the reference situation (p < 0.001) and no differences were found among the three astigmatic situations (p = 0.21). Conclusions. Low residual defocus and mixed astigmatic errors, regardless of its orientation, seem to be tolerated by patients implanted with the studied EDoF IOL. This trial is registered with NCT05392998. Registered 26 May 2022-Retrospectively registered.
引用
收藏
页数:5
相关论文
共 14 条
  • [1] Intermediate visual function with different multifocal intraocular lens models
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    Puchades, Cristina
    Montes-Mico, Robert
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (05) : 733 - 739
  • [2] Extended depth-of-focus (EDOF) AcrySof® IQ Vivity® intraocular lens implant: a real-life experience
    Arrigo, Alessandro
    Gambaro, Gianpiera
    Fasce, Francesco
    Aragona, Emanuela
    Figini, Innocente
    Bandello, Francesco
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 259 (09) : 2717 - 2722
  • [4] Borkenstein Andreas F, 2021, Biomed Hub, V6, P77, DOI 10.1159/000519139
  • [5] Assessment of dysphotopsia in pseudophakic subjects with multifocal intraocular lenses
    Buckhurst, Phillip J.
    Naroo, Shehzad A.
    Davies, Leon N.
    Shah, Sunil
    Drew, Tom
    Wolffsohn, James S.
    [J]. BMJ OPEN OPHTHALMOLOGY, 2016, 1 (01):
  • [6] The Effect of Spectacle-Induced Low Myopia in the Non-Dominant Eye on the Binocular Defocus Curve with a Non-Diffractive Extended Vision Intraocular Lens
    Gundersen, Kjell G.
    Potvin, Richard
    [J]. CLINICAL OPHTHALMOLOGY, 2021, 15 : 3541 - 3547
  • [7] Effect of Spherical Equivalent Error on Visual Acuity at Various Distances in Eyes With a Trifocal Intraocular Lens
    Hayashi, Ken
    Sato, Tatshuhiko
    Igarashi, Chizuka
    Yoshida, Motoaki
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2019, 35 (05) : 274 - 279
  • [8] Comparison of a trifocal intraocular lens with a+3.0 D bifocal IOL: Results of a prospective randomized clinical trial
    Jonker, Soraya M. R.
    Bauer, Noel J. C.
    Makhotkina, Natalia Y.
    Berendschot, Tos T. J. M.
    van den Biggelaar, Frank J. H. M.
    Nuijts, Rudy M. M. A.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (08) : 1631 - 1640
  • [9] Nondiffractive wavefront-shaping extended depth-of-focus intraocular lens: visual performance and patient-reported outcomes
    Kohnen, Thomas
    Petermann, Kerstin
    Boehm, Myriam
    Hemkeppler, Eva
    Ahmad, Wasim
    Hinzelmann, Lisa
    Pawlowicz, Katarzyna
    Jandewerth, Tyll
    Lwowski, Christoph
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (02) : 144 - 150
  • [10] Extended depth-of-focus technology in intraocular lenses
    Kohnen, Thomas
    Suryakumar, Rajaraman
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (02) : 298 - 304