Mass ratio factor in control performance of optimum tuned liquid dampers

被引:1
作者
Ocak, Ayla [1 ]
Bekdas, Gebrail [1 ]
Nigdeli, Sinan Melih [1 ,2 ]
机构
[1] Istanbul Univ Cerrahpasa, Dept Civil Engn, Istanbul, Turkiye
[2] Istanbul Univ Cerrahpasa, Dept Civil Engn, TR-34320 Istanbul, Turkiye
关键词
damping; Jaya algorithm; mass ratio; optimization; structural control; Tuned liquid damper (TLD); SEISMIC VIBRATION CONTROL; COLUMN DAMPER; RESPONSE CONTROL; OPTIMAL-DESIGN; MOTION; SYSTEM;
D O I
10.1002/tal.2063
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Tuned liquid dampers provide structure control with the help of the liquid mass in tanks that are attached to the structure. The mass ratio affects the optimum tuned liquid damper (TLD) parameters. This study examines the effect of mass ratio on the control performance of TLD devices in providing seismic control of structures with different damping ratios. For this purpose, TLD devices with different mass ratios were placed on two different single-story steel and reinforced concrete structure models, and their performance under earthquake excitation was investigated. TLD parameters for obtaining the optimum displacement level in the 0.5- and 1.0-s structure natural period for both structure types were optimized with the Jaya algorithm (JA), which is a metaheuristic algorithm. By using the optimum TLD parameters, the structural displacement and total acceleration values were obtained by the critical earthquake analysis. When the results are examined, it is understood that TLD mass increase from a 20% mass ratio for both structure types and selected structure periods does not have a significant effect on TLD control performance.
引用
收藏
页数:16
相关论文
共 50 条
[41]   Two-stage optimum design of tuned mass dampers with consideration of stroke [J].
Wang, Jer-Fu ;
Lin, Chi-Chang ;
Lian, Chien-Hsun .
STRUCTURAL CONTROL & HEALTH MONITORING, 2009, 16 (01) :55-72
[42]   Performance of tuned liquid column dampers considering maximum liquid motion in seismic vibration control of structures [J].
Chakraborty, Subrata ;
Debbarma, Rama ;
Marano, Giuseppe Carlo .
JOURNAL OF SOUND AND VIBRATION, 2012, 331 (07) :1519-1531
[43]   Improving the performance of tuned mass dampers by considering geometric nonlinear effects in an integrated identification-control approach [J].
Ghaderi, Pedram ;
Gholam, Samaneh .
SMART MATERIALS AND STRUCTURES, 2023, 32 (12)
[44]   Active multiple tuned mass dampers: A new control strategy [J].
Li, CX ;
Liu, YX ;
Wang, ZM .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2003, 129 (07) :972-977
[45]   Optimal structural control of tall buildings using tuned mass dampers via chaotic optimization algorithm [J].
Kaveh, A. ;
Javadi, S. M. ;
Moghanni, R. Mahdipour .
STRUCTURES, 2020, 28 :2704-2713
[46]   Multiple Tuned Liquid Dampers for Efficient and Robust Structural Control [J].
Love, J. S. ;
Tait, M. J. .
JOURNAL OF STRUCTURAL ENGINEERING, 2015, 141 (12)
[47]   Optimization Strategies of Hysteretic Tuned Mass Dampers for Seismic Control [J].
Boccamazzo, Antonio ;
Carboni, Biagio ;
Quaranta, Giuseppe ;
Lacarbonara, Walter .
NONLINEAR DYNAMICS AND CONTROL, VOL II: PROCEEDINGS OF THE FIRST INTERNATIONAL NONLINEAR DYNAMICS CONFERENCE (NODYCON 2019), 2020, :99-106
[48]   Experimental study on control performance of tuned liquid column dampers considering different excitation directions [J].
Altunisik, Ahmet Can ;
Yetisken, Ali ;
Kahya, Volkan .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2018, 102 :59-71
[49]   Tuned liquid dampers simulation for earthquake response control of buildings [J].
Novo, T. ;
Varum, H. ;
Teixeira-Dias, F. ;
Rodrigues, H. ;
Falcao Silva, M. ;
Campos Costa, A. ;
Guerreiro, L. .
BULLETIN OF EARTHQUAKE ENGINEERING, 2014, 12 (02) :1007-1024
[50]   Optimum Design of Tuned Mass Dampers for Structures with Torsional Irregularity via Jaya Algorithm [J].
Apaer Mubuli ;
Sinan Melih Nigdeli ;
Gebrail Bekdaş .
Journal of Vibration Engineering & Technologies, 2024, 12 :2279-2293