Mass ratio factor in control performance of optimum tuned liquid dampers

被引:1
作者
Ocak, Ayla [1 ]
Bekdas, Gebrail [1 ]
Nigdeli, Sinan Melih [1 ,2 ]
机构
[1] Istanbul Univ Cerrahpasa, Dept Civil Engn, Istanbul, Turkiye
[2] Istanbul Univ Cerrahpasa, Dept Civil Engn, TR-34320 Istanbul, Turkiye
关键词
damping; Jaya algorithm; mass ratio; optimization; structural control; Tuned liquid damper (TLD); SEISMIC VIBRATION CONTROL; COLUMN DAMPER; RESPONSE CONTROL; OPTIMAL-DESIGN; MOTION; SYSTEM;
D O I
10.1002/tal.2063
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Tuned liquid dampers provide structure control with the help of the liquid mass in tanks that are attached to the structure. The mass ratio affects the optimum tuned liquid damper (TLD) parameters. This study examines the effect of mass ratio on the control performance of TLD devices in providing seismic control of structures with different damping ratios. For this purpose, TLD devices with different mass ratios were placed on two different single-story steel and reinforced concrete structure models, and their performance under earthquake excitation was investigated. TLD parameters for obtaining the optimum displacement level in the 0.5- and 1.0-s structure natural period for both structure types were optimized with the Jaya algorithm (JA), which is a metaheuristic algorithm. By using the optimum TLD parameters, the structural displacement and total acceleration values were obtained by the critical earthquake analysis. When the results are examined, it is understood that TLD mass increase from a 20% mass ratio for both structure types and selected structure periods does not have a significant effect on TLD control performance.
引用
收藏
页数:16
相关论文
共 50 条
[31]   Optimum Design of Single and Multiple Tuned Mass Dampers for Vibration Control in Buildings Under Seismic Excitation [J].
Brandao, Francisco da Silva ;
de Almeida, Alex Koch ;
Fadel Miguel, Leticia Fleck .
INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2022, 22 (08)
[32]   Tuned Mass Dampers for Dual-Mode Buffeting Control of Bridges [J].
Chang, C. C. ;
Gu, M. ;
Tang, K. H. .
JOURNAL OF BRIDGE ENGINEERING, 2003, 8 (04) :237-240
[33]   Optimum design of a sliding mode control for seismic mitigation of structures equipped with active tuned mass dampers [J].
Eliasi, Hussein ;
Yazdani, Hessam ;
Khatibinia, Mohsen ;
Mahmoudi, Mehdi .
STRUCTURAL ENGINEERING AND MECHANICS, 2022, 81 (05) :633-645
[34]   VIBRATION CONTROL EFFECTIVENESS OF PASSIVE TUNED MASS DAMPERS [J].
LIN, CC ;
HU, CM ;
WANG, JF ;
HU, RY .
JOURNAL OF THE CHINESE INSTITUTE OF ENGINEERS, 1994, 17 (03) :367-376
[35]   PERFORMANCE OF TUNED MASS DAMPERS UNDER WIND LOADS [J].
KWOK, KCS ;
SAMALI, B .
ENGINEERING STRUCTURES, 1995, 17 (09) :655-667
[36]   Combined Tuned Mass Dampers for structural vibration control [J].
Cao, Huong Quoc .
INTERNATIONAL JOURNAL OF NON-LINEAR MECHANICS, 2023, 157
[37]   Vibration suppression of offshore wind turbine foundations using tuned liquid column dampers and tuned mass dampers [J].
Hemmati, Arash ;
Oterkus, Erkan ;
Khorasanchi, Mandi .
OCEAN ENGINEERING, 2019, 172 :286-295
[38]   Pendulum tuned mass dampers for floor vibration control [J].
Setareh, M ;
Ritchey, JK ;
Baxter, AJ ;
Murray, TM .
JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2006, 20 (01) :64-73
[39]   Optimum design and experimental study of multiple tuned mass dampers with limited stroke [J].
Lin, Chi-Chang ;
Wang, Jer-Fu ;
Lien, Chien-Hsun ;
Chiang, Hung-Wei ;
Lin, Chih-Shiuan .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2010, 39 (14) :1631-1651
[40]   Optimum Tuned Mass Dampers under seismic Soil-Structure Interaction [J].
Salvi, Jonathan ;
Pioldi, Fabio ;
Rizzi, Egidio .
SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2018, 114 :576-597