Modifying the trajectory of epicardial leads can substantially reduce MRI-induced RF heating in pediatric patients with a cardiac implantable electronic device at 1.5T

被引:2
作者
Jiang, Fuchang [1 ]
Bhusal, Bhumi [2 ]
Nguyen, Bach [2 ]
Monge, Michael [3 ]
Webster, Gregory [4 ]
Kim, Daniel [2 ]
Bonmassar, Giorgio [5 ]
Popsecu, Andrada R. [6 ]
Golestanirad, Laleh [1 ,2 ,7 ]
机构
[1] Northwestern Univ, McCormick Sch Engn, Dept Biomed Engn, Evanston, IL USA
[2] Northwestern Univ, Feinberg Sch Med, Dept Radiol, Chicago, IL USA
[3] Ann & Robert H Lurie Childrens Hosp Chicago, Div Cardiovasc Thorac Surg, Chicago, IL USA
[4] Northwestern Univ, Ann & Robert H Lurie Childrens Hosp Chicago, Feinberg Sch Med, Div Cardiol, Chicago, IL USA
[5] Massachusetts Gen Hosp, AA Martinos Ctr Biomed Imaging, Boston, MA USA
[6] Ann & Robert H Lurie Childrens Hosp Chicago, Div Med Imaging, Chicago, IL USA
[7] Northwestern Univ, Feinberg Sch Med, Dept Radiol, 737 N Michigan Ave,Suite 1600, Chicago, IL 60611 USA
基金
美国国家卫生研究院;
关键词
cardiovascular implantable electronic devices; epicardial leads; RF heating; safety; MANAGE COMPLICATIONS; PACEMAKERS; SAFE; EXTRACTION; SIMULATION; RECOGNIZE; PREVENT; DESIGN; FIELD;
D O I
10.1002/mrm.29776
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: After epicardial cardiac implantable electronic devices are implanted in pediatric patients, they become ineligible to receive MRI exams due to an elevated risk of RF heating. We investigated whether simple modifications in the trajectories of epicardial leads could substantially and reliably reduce RF heating during MRI at 1.5 T, with benefits extending to abandoned leads.Methods: Electromagnetic simulations were performed to assess RF heating of two common 35-cm epicardial lead trajectories exhibiting different degrees of coupling with MRI incident electric fields. Experiments in anthropomorphic phantoms implanted with commercial cardiac implantable electronic devices confirmed the findings. Both electromagnetic simulations and experimental measurements were performed using head-first and feet-first positioning and various landmarks. Transfer function approach was used to assess the performance of suggested modifications in realistic body models.Results: Simulations (head-first, chest landmark) of a 35-cm epicardial lead with a trajectory where the excess length of the lead was looped and placed on the inferior surface of the heart showed an 87-fold reduction in the 0.1 g-averaged specific absorption rate compared with the lead where the excess length was looped on the anterior surface. Repeated experiments with a commercial epicardial device confirmed this. For fully implanted systems following low-specific absorption rate trajectories, there was a 16-fold reduction in the average temperature rise and a 28-fold reduction for abandoned leads. The transfer function method predicted a 7-fold reduction in the RF heating in 336 realistic scenarios.Conclusion: Surgical modification of epicardial lead trajectory can substantially reduce RF heating at 1.5 T, with benefits extending to abandoned leads.
引用
收藏
页码:2510 / 2523
页数:14
相关论文
共 52 条
[1]   Effects of magnetic resonance Imaging on cardiac pacemakers and electrodes [J].
Achenbach, S ;
Moshage, W ;
Diem, B ;
Bieberle, T ;
Schibgilla, V ;
Bachmann, K .
AMERICAN HEART JOURNAL, 1997, 134 (03) :467-473
[2]  
[Anonymous], 2020, 6270442020 IEEEIEC
[3]  
Atalar E., ATALAR E
[4]   REDUCTION OF MAGNETIC RESONANCE IMAGING-RELATED HEATING IN DEEP BRAIN STIMULATION LEADS USING A LEAD MANAGEMENT DEVICE [J].
Baker, Kenneth B. ;
Tkach, Jean ;
Hall, John D. ;
Nyenhuis, John A. ;
Shellock, Frank G. ;
Rezai, Ali R. .
NEUROSURGERY, 2005, 57 (04) :392-396
[5]   Magnetic resonance imaging of patients with epicardial leads: in vitro evaluation of temperature changes at the lead tip [J].
Balmer, Christian ;
Gass, Matthias ;
Dave, Hitendu ;
Duru, Firat ;
Luechinger, Roger .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2019, 56 (03) :321-326
[6]   Effect of Device Configuration and Patient's Body Composition on theRFHeating and Nonsusceptibility Artifact of Deep Brain Stimulation Implants DuringMRIat 1.5T and 3T [J].
Bhusal, Bhumi ;
Nguyen, Bach T. ;
Sanpitak, Pia P. ;
Vu, Jasmine ;
Elahi, Behzad ;
Rosenow, Joshua ;
Nolt, Mark J. ;
Lopez-Rosado, Roberto ;
Pilitsis, Julie ;
DiMarzio, Marisa ;
Golestanirad, Laleh .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 53 (02) :599-610
[7]  
Bonow RO, 2008, J AM COLL CARDIOL, V52, pE1, DOI [10.1016/j.jacc.2008.05.007, 10.1016/j.hrthm.2008.04.014]
[8]  
Bottomley PA., BOTTOMLEY PA
[9]   Designing passive MRI-safe implantable conducting leads with electrodes [J].
Bottomley, Paul A. ;
Kumar, Ananda ;
Edelstein, William A. ;
Allen, Justin M. ;
Karmarkar, Parag V. .
MEDICAL PHYSICS, 2010, 37 (07) :3828-3843
[10]  