Two-dimensional separation of water-soluble polymers using size exclusion and reversed phase chromatography employing capillary-channeled polymer fiber columns *

被引:2
作者
Wysor, Sarah K. [1 ]
Marcus, Kenneth [1 ]
机构
[1] Clemson Univ, Dept Chem, Biosyst Res Complex, Clemson, SC 29634 USA
基金
美国国家科学基金会;
关键词
Two-dimensional liquid chromatography; (2DLC); Water-soluble polymers; Capillary channeled polymer fiber; Size exclusion chromatography; Reversed phase chromatography; EFFECTIVE PEAK-CAPACITY; LIQUID-CHROMATOGRAPHY; STATIONARY PHASES; PROTEIN-A; CATIONIC SURFACTANTS; POLY(ACRYLIC ACID); LIGHT-SCATTERING; PERFORMANCE; ORTHOGONALITY; COUNTERION;
D O I
10.1016/j.chroma.2023.464051
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Polymeric materials are readily available, durable materials that have piqued the interest of many diverse fields, ranging from biomedical engineering to construction. The physiochemical properties of a polymer dictate the behavior and function, where large polydispersity among polymer properties can lead to problems; however, current polymer analysis methods often only report results for one particular property. Two-dimensional liquid chromatography (2DLC) applications have become increasingly popular due to the ability to implement two chromatographic modalities in one platform, meaning the ability to simultaneously address multiple physiochemical aspects of a polymer sample, such as functional group content and molar mass. The work presented employs size exclusion chromatography (SEC) and reversed-phase (RP) chromatography, through two coupling strategies: SEC x RP and RP x RP separations of the watersoluble polymers poly(methacrylic acid) (PMA) and polystyrene sulfonic acid (PSSA). Capillary-channeled polymer (C-CP) fiber (polyester and polypropylene) stationary phases were used for the RP separations. Particularly attractive is the fact that they are easily implemented as the second dimension in 2DLC workflows due to their low backpressure ( < 10 0 0 psi at similar to 70 mm sec -1 ) and fast separation times. In-line multi-angle light scattering (MALS) was also implemented for molecular weight determinations of the polymer samples, with the molecular weight of PMA ranging from 5 x 10 4 to 2 x 10 5 g mol -1 , while PSSA ranges from 10 5 to 10 8 g mol -1 . While the orthogonal pairing of SEC x RP addresses polymer sizing and chemistry, this approach is limited by long separation times (80 min), the need for high solute concentrations (PMA = 1.79 mg mL -1 and PSSA = 0.175 mg mL -1 to yield comparable absorbance responses) due to on-column dilution and subsequently limited resolution in the RP separation space. With RP x RP couplings, separation times were significantly reduced (40 min), with lower sample concentrations (0.595 mg mL -1 of PMA and 0.05 mg mL -1 of PSSA) required. The combined RP strategy provided better overall distinction in the chemical distribution of the polymers, yielding 7 distict species versus 3 for the SEC x RP coupling.
引用
收藏
页数:14
相关论文
共 73 条
  • [1] Counterion Effect of Cationic Surfactants Upon the Interaction with Poly(methacrylic acid)
    Anghel, Dan Florin
    Saito, Shuji
    Iovescu, Alina
    Baran, Adriana
    Stinga, Gabriela
    [J]. JOURNAL OF SURFACTANTS AND DETERGENTS, 2011, 14 (01) : 91 - 101
  • [2] Recent developments in the detailed characterization of polymers by multidimensional chromatography
    Baumgaertel, Anja
    Altuntas, Esra
    Schubert, Ulrich S.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2012, 1240 : 1 - 20
  • [3] Optimal gradient operation in comprehensive liquid chromatography x liquid chromatography systems with limited orthogonality
    Bedani, Filippo
    Kok, Wim Th.
    Janssen, Hans-Gerd
    [J]. ANALYTICA CHIMICA ACTA, 2009, 654 (01) : 77 - 84
  • [4] Size exclusion chromatography - A blessing and a curse of science and technology of synthetic polymers
    Berek, Dusan
    [J]. JOURNAL OF SEPARATION SCIENCE, 2010, 33 (03) : 315 - 335
  • [5] Two-dimensional liquid chromatography of synthetic polymers
    Berek, Dusan
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (01) : 421 - 441
  • [6] Comparative analysis of trilobal capillary-channeled polymer fiber columns with superficially porous and monolithic phases toward reversed-phase protein separations
    Billotto, Lacey S.
    Marcus, R. Kenneth
    [J]. JOURNAL OF SEPARATION SCIENCE, 2022, 45 (20) : 3811 - 3826
  • [7] Spectroscopic Techniques for the Characterization of Polymer Nanocomposites: A Review
    Bokobza, Liliane
    [J]. POLYMERS, 2018, 10 (01)
  • [8] Advances in size-exclusion separations of proteins and polymers by UHPLC
    Bouvier, Edouard S. P.
    Koza, Stephan M.
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2014, 63 : 85 - 94
  • [9] Smart Polymers for Advanced Applications: A Mechanical Perspective Review
    Brighenti, Roberto
    Li, Ying
    Vernerey, Franck J.
    [J]. FRONTIERS IN MATERIALS, 2020, 7 (07):
  • [10] Advances on Size Exclusion Chromatography and Applications on the Analysis of Protein Biopharmaceuticals and Protein Aggregates: A Mini Review
    Brusotti, Gloria
    Calleri, Enrica
    Colombo, Raffaella
    Massolini, Gabriella
    Rinaldi, Francesca
    Temporini, Caterina
    [J]. CHROMATOGRAPHIA, 2018, 81 (01) : 3 - 23