Rational design of Ti3C2 MXene nanocomposite with bromophenol blue for efficient signal amplification: Sensitive electrochemical detection of cardiac troponin I in patient plasma

被引:60
作者
Khoshfetrat, Seyyed Mehdi [1 ]
Chegeni, Iman [1 ]
机构
[1] Ayatollah Boroujerdi Univ, Fac Basic Sci, Dept Chem, Boroujerd, Iran
关键词
Cardiac troponin I; Aptasensor; Electrochemical; Hydrogen peroxide; Nanocomposite; EXFOLIATION; GRAPHENE;
D O I
10.1016/j.snb.2023.134668
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Today, although a new generation of two-dimensional (2D) MXenes has received considerable interest throughout several fields, the rational design of MXene-based nanocomposites and their particular applications in biosensors remain serious challenges. Herein, to avoid etched-loosely accumulated accordion-like structure of Ti3C2 MXene to restacking, delamination was conducted using bromophenol blue (BPB), which makes the resulting BPB@Ti3C2 nanocomposite as an ideal nanolable for ultrasensitive detection of acute myocardial infarction (AMI) biomarker (cardiac troponin I, cTnI). For this purpose, after sandwiching the cTnI between covalently-bonded Tro4 aptamer on the BPB@Ti3C2 and MNPs/Tro6, the electrocatalytic activity of the nano -label towards H2O2 was followed as a tracer signal. Owing to i) high effective surface area for immobilization of the Tro4 and ii) large electrocatalytic activity of the BPB@Ti3C2 for electroreduction of H2O2, along with iii) enrichment characteristic of the MNPs/Tro6, as well as iv) the synergistic-assisted signal amplification between the Ti3C2 and BPB, high sensitive detection of cTnI has been introduced. The developed biofunctionalized BPB@Ti3C2 exhibits a wide dynamic range of 200 fg mL-1-250 ng mL-1 with a low detection limit of 20 fg mL-1. The aptasandwich form was used to quantify the cTnI in the human blood plasma of cardiovascular patients, above 90% clinical sensitivity, providing a promising strategy for clinical diagnosis and biochemistry research.
引用
收藏
页数:9
相关论文
共 56 条
[1]   Microfluidic Immuno-Biochip for Detection of Breast Cancer Biomarkers Using Hierarchical Composite of Porous Graphene and Titanium Dioxide Nanofibers [J].
Ali, Md. Azahar ;
Mondal, Kunal ;
Jiao, Yueyi ;
Oren, Seval ;
Xu, Zhen ;
Sharma, Ashutosh ;
Dong, Liang .
ACS APPLIED MATERIALS & INTERFACES, 2016, 8 (32) :20570-20582
[2]   Adverse Cardiac Remodelling after Acute Myocardial Infarction: Old and New Biomarkers [J].
Berezin, Alexander E. ;
Berezin, Alexander A. .
DISEASE MARKERS, 2020, 2020
[3]   A survey on ECG analysis [J].
Berkaya, Selcan Kaplan ;
Uysal, Alper Kursat ;
Gunal, Efnan Sora ;
Ergin, Semih ;
Gunal, Serkan ;
Gulmezoglu, M. Bilginer .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2018, 43 :216-235
[4]   Understanding Functionalization of Titanium Carbide (MXene) with Quinones and Their Pseudocapacitance [J].
Boota, Muhammad ;
Urbankowski, Patrick ;
Porzio, William ;
Barba, Luisa ;
Osti, Naresh C. ;
Bleuel, Markus ;
Keum, Jong K. ;
Mamontov, Eugene .
ACS APPLIED ENERGY MATERIALS, 2020, 3 (05) :4127-4133
[5]   Sensitive electrochemical detection of cardiac troponin I in serum and saliva by nitrogen-doped porous reduced graphene oxide electrode [J].
Chekin, Fereshteh ;
Vasilescu, Alina ;
Jijie, Roxana ;
Singh, Santosh K. ;
Kurungot, Sreekumar ;
Iancu, Madalina ;
Badea, Gabriela ;
Boukherroub, Rabah ;
Szunerits, Sabine .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 262 :180-187
[6]   MXene Titanium Carbide-based Biosensor: Strong Dependence of Exfoliation Method on Performance [J].
Chia, Hui Ling ;
Mayorga-Martinez, Carmen C. ;
Antonatos, Nikolas ;
Sofer, Zdenek ;
Gonzalez-Julian, Jesus J. ;
Webster, Richard D. ;
Pumera, Martin .
ANALYTICAL CHEMISTRY, 2020, 92 (03) :2452-2459
[7]   Progress, Opportunities, and Challenges of Troponin Analysis in the Early Diagnosis of Cardiovascular Diseases [J].
Du, Xuewei ;
Su, Xujie ;
Zhang, Wanxue ;
Yi, Suyan ;
Zhang, Ge ;
Jiang, Shan ;
Li, Hui ;
Li, Shaoguang ;
Xia, Fan .
ANALYTICAL CHEMISTRY, 2022, 94 (01) :442-463
[8]   An aptamer-binding DNA walking machine for sensitive electrochemiluminescence detection of tumor exosomes [J].
Feng, Qiu-Mei ;
Ma, Po ;
Cao, Qi-Hang ;
Guo, Yue-Hua ;
Xu, Jing-Juan .
CHEMICAL COMMUNICATIONS, 2020, 56 (02) :269-272
[9]   Electrochemical Immunosensor for Cardiac Troponin I Detection Based on Covalent Organic Framework and Enzyme-Catalyzed Signal Amplification [J].
Feng, Sinuo ;
Yan, Mengxia ;
Xue, Yu ;
Huang, Jianshe ;
Yang, Xiurong .
ANALYTICAL CHEMISTRY, 2021, 93 (40) :13572-13579
[10]   Three-Dimensional Porous Ti3C2Tx MXene-Graphene Hybrid Films for Glucose Biosensing [J].
Gu, Hui ;
Xing, Yidan ;
Xiong, Ping ;
Tang, Huiling ;
Li, Chenchen ;
Chen, Shu ;
Zeng, Rongjin ;
Han, Kai ;
Shi, Guoyue .
ACS APPLIED NANO MATERIALS, 2019, 2 (10) :6537-6545