Parametric study on lateral behavior of totally precast RC shear wall with horizontal bolted connection

被引:9
|
作者
Sun, Jian [1 ]
Wang, Tianmeng [1 ]
Sun, Haoyuan [1 ]
Ruan, Shihao [1 ]
Qiu, Hongxing [1 ]
机构
[1] Southeast Univ, Minist Educ, Key Lab Concrete & Prestressed Concrete Struct, Nanjing 211102, Peoples R China
关键词
Totally precast reinforced concrete shear wall; Horizontal connection; High strength bolt; ABAQUS; Finite element analysis; SEISMIC PERFORMANCE;
D O I
10.1016/j.istruc.2023.105100
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Dry-type connections have gained considerable popularity worldwide due to their superior construction efficiency and quality. However, a significant drawback of most conventional dry-type connections is the direct embedding of connectors in the concrete wall panel, consequently causing stress concentration in the connections and leading to extensive spalling of concrete. This study introduces an innovative high-strength bolted connection as a solution to address the problem of stress concentration in concrete. To evaluate the seismic performance of the high-strength bolted connection, monotonic lateral loading tests were conducted. In this study, a finite element (FE) model was developed using ABAQUS software, and validated through experimental results. Furthermore, a parametric study was conducted using the FE model to assess the influence of several key design parameters on the lateral response and anti-slip capacity of the bolted connection in the precast shear wall. These parameters include bolt specifications, anti-slip coefficient, flange thickness of the H-connector, widths of the initial gap, axial compression ratio, and connection arrangement. The results indicate that the antislip capacity is not significantly influenced by the flange thickness of H-connectors and initial gap width, but it increases with an increase in bolt specification, slip coefficient, and axial compression ratio. Additionally, the ultimate bearing capacity of the precast shear wall remains unaffected by both the anti-slip coefficient and the initial gap width. Moreover, the high-stress area of the H-connector is concentrated at the ends. Finally, the design parameters are recommended according to the numerical analysis results.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Experimental Study on Shear Resistance of Precast RC Shear Walls with Novel Bundled Connections
    Chen, Yao
    Zhang, Qian
    Feng, Jian
    Zhang, Zhe
    JOURNAL OF EARTHQUAKE AND TSUNAMI, 2019, 13 (3-4)
  • [32] Experimental campaign of horizontal cladding wall panels connection in industrial precast reinforced concrete buildings
    Ostetto, Liana
    Fonseca, Jorge
    Sousa, Romain
    Fernandes, Paulo
    Rodrigues, Hugo
    ENGINEERING STRUCTURES, 2025, 322
  • [33] Study on the shear mechanism of horizontal joints within UVDR precast shear wall by quasi-static test and finite element analysis
    Cao, Zhi-Wei
    Fang, Hai-Bo
    Tian, Li
    Zhang, Shi-Qian
    Du, Zhi-Hao
    Liu, Xiong
    RESULTS IN ENGINEERING, 2024, 23
  • [34] Parametric studies on punching shear behavior of RC flat slabs without shear reinforcement
    Elsamak, Galal
    Fayed, Sabry
    COMPUTERS AND CONCRETE, 2020, 25 (04) : 355 - 367
  • [35] Experimental validation on seismic performance of a monolithic precast RC shear wall structure with novel connections
    Wang, Xiao-ting
    Chen, Xi
    Wang, Tao
    Pan, Peng
    Miao, Qi-song
    ADVANCES IN STRUCTURAL ENGINEERING, 2022, 25 (05) : 1042 - 1056
  • [36] A parametric study on ultimate strength of single shear bolted connections with curling
    Kim, T. S.
    Kuwamura, H.
    Cho, T. J.
    THIN-WALLED STRUCTURES, 2008, 46 (01) : 38 - 53
  • [37] EFFECT OF PRECAST FILLED WALL WITH POLYSTYRENE PLATE HORIZONTAL JOINT ON SEISMIC PERFORMANCE OF SHEAR WALLS
    Zhang W.-J.
    Leng T.-Y.
    Qian J.-R.
    Gongcheng Lixue/Engineering Mechanics, 2023, 40 (11): : 140 - 154
  • [38] Seismic performance of a novel partial precast RC shear wall with reserved cast-in-place base and wall edges
    Wu, Suiwen
    Li, Huaqiang
    Wang, Xu
    Li, Ran
    Tian, Chunyu
    Hou, Quansheng
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2022, 152
  • [39] Experimental study and associated numerical simulation of horizontally connected precast shear wall assembly
    Sun, Jian
    Qiu, Hongxing
    Lu, Yong
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2016, 25 (13) : 659 - 678
  • [40] Analysis of prefabricated slab influence on lateral behavior of precast frame under horizontal load
    Pan C.
    Huang X.
    Xu F.
    Chen C.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2018, 39 : 72 - 78