Parametric study on lateral behavior of totally precast RC shear wall with horizontal bolted connection

被引:9
|
作者
Sun, Jian [1 ]
Wang, Tianmeng [1 ]
Sun, Haoyuan [1 ]
Ruan, Shihao [1 ]
Qiu, Hongxing [1 ]
机构
[1] Southeast Univ, Minist Educ, Key Lab Concrete & Prestressed Concrete Struct, Nanjing 211102, Peoples R China
关键词
Totally precast reinforced concrete shear wall; Horizontal connection; High strength bolt; ABAQUS; Finite element analysis; SEISMIC PERFORMANCE;
D O I
10.1016/j.istruc.2023.105100
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Dry-type connections have gained considerable popularity worldwide due to their superior construction efficiency and quality. However, a significant drawback of most conventional dry-type connections is the direct embedding of connectors in the concrete wall panel, consequently causing stress concentration in the connections and leading to extensive spalling of concrete. This study introduces an innovative high-strength bolted connection as a solution to address the problem of stress concentration in concrete. To evaluate the seismic performance of the high-strength bolted connection, monotonic lateral loading tests were conducted. In this study, a finite element (FE) model was developed using ABAQUS software, and validated through experimental results. Furthermore, a parametric study was conducted using the FE model to assess the influence of several key design parameters on the lateral response and anti-slip capacity of the bolted connection in the precast shear wall. These parameters include bolt specifications, anti-slip coefficient, flange thickness of the H-connector, widths of the initial gap, axial compression ratio, and connection arrangement. The results indicate that the antislip capacity is not significantly influenced by the flange thickness of H-connectors and initial gap width, but it increases with an increase in bolt specification, slip coefficient, and axial compression ratio. Additionally, the ultimate bearing capacity of the precast shear wall remains unaffected by both the anti-slip coefficient and the initial gap width. Moreover, the high-stress area of the H-connector is concentrated at the ends. Finally, the design parameters are recommended according to the numerical analysis results.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Research on seismic behavior of precast concrete shear wall with new steel plate-bolted horizontal connection
    Yu, Haifeng
    Zhang, Huijie
    Zhang, Pengfei
    Ma, Kang
    Zhang, Hua
    Qiao, Jin
    JOURNAL OF BUILDING ENGINEERING, 2024, 85
  • [2] Lateral load behaviour of a rectangular precast shear wall involving vertical bolted connections
    Sun, Jian
    Qiu, Hongxing
    Jiang, Hongbo
    ADVANCES IN STRUCTURAL ENGINEERING, 2019, 22 (05) : 1211 - 1224
  • [3] Experimental study on hysteresis behavior of precast concrete double skin shear wall with horizontal loop connection and spiral-confined vertical lap connection
    Jiang, Jiafei
    Luo, Jie
    Xue, Weichen
    Hu, Xiang
    Qin, Duan
    JOURNAL OF BUILDING ENGINEERING, 2022, 45
  • [4] Experimental validation of horizontal joints in an innovative totally precast shear wall system
    Sun, Jian
    Qiu, Hongxing
    Lu, Bo
    Journal of Southeast University (English Edition), 2015, 31 (01) : 124 - 129
  • [5] Experimental Study and Numerical Simulation of Precast Shear Wall with Rabbet-Unbonded Horizontal Connection
    Sun, Chong-fang
    Liang, Shu-ting
    Zhu, Xiao-jun
    Li, Hu
    Guo, Jian-min
    Li, Gang
    Song, Ya-min
    Wu, Dong-yue
    INTERNATIONAL JOURNAL OF CONCRETE STRUCTURES AND MATERIALS, 2020, 14 (01)
  • [6] Experiment and numerical study of a new bolted steel plate horizontal joints for precast concrete shear wall structures
    Cheng, Bei
    Cai, Yuan
    Looi, Daniel T. W.
    STRUCTURES, 2021, 32 : 760 - 777
  • [7] Experimental study and associated mechanism analysis of horizontal bolted connections involved in a precast concrete shear wall system
    Sun, Jian
    Qiu, Hongxing
    Jiang, Hongbo
    STRUCTURAL CONCRETE, 2019, 20 (01) : 282 - 295
  • [8] Experimental study on rectangular precast reinforced concrete shear wall utilizing bolted connections
    Sun J.
    Qiu H.
    Tan Z.
    Yang Y.
    Qiu, Hongxing (qiuhx@seu.edu.cn), 1600, Science Press (37): : 67 - 75
  • [9] Experimental Study on Mechanical Behavior of Fully Assembled Composite Wall with Bolted Connection on Horizontal Joints
    Miao X.
    Huang W.
    Hu G.
    Zhang J.
    Fan Z.
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2021, 48 (05): : 19 - 28
  • [10] Seismic Performance of Precast Double-Skin Composite Shear Wall with Horizontal Connection Region
    Liu, Huanqin
    Shi, Nuoqi
    Fu, Xu
    Zhang, Jingjing
    BUILDINGS, 2024, 14 (06)