Real-world evidence for the use of subcutaneous implantable cardioverter-defibrillators in China: A single-center experience

被引:0
作者
Zhang, Lei [1 ,2 ]
Li, Xiao [1 ,2 ]
Liang, Yixiu [1 ,2 ]
Wang, Jingfeng [1 ,2 ]
Li, Minghui [1 ,2 ]
Pan, Lei [1 ,2 ]
Chen, Xueying [1 ,2 ]
Qin, Shengmei [1 ,2 ]
Bai, Jin [1 ,2 ]
Wang, Wei [1 ,2 ]
Su, Yangang [1 ,2 ,3 ]
Ge, Junbo [1 ,2 ,3 ]
机构
[1] Fudan Univ, Zhongshan Hosp, Shanghai Inst Cardiovasc Dis, Dept Cardiol, Shanghai, Peoples R China
[2] Shanghai Clin Res Ctr Intervent Med, Natl Clin Res Ctr Intervent Med, Shanghai, Peoples R China
[3] Fudan Univ, Zhongshan Hosp, Shanghai Inst Cardiovasc Dis, Dept Cardiol, Xietu Rd 1069, Shanghai, Peoples R China
关键词
Subcutaneous implantable cardioverter-defibrillator; Sudden cardiac death; Efficacy; Safety; Chinese population; S-ICD; OUTCOMES; PREVENTION; SOCIETY; SHOCKS;
D O I
10.1007/s00059-023-05192-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundSubcutaneous implantable cardioverter-defibrillators (S-ICDs) have been shown to be non-inferior to transvenous ICDs in the prevention of sudden cardiac death (SCD), but there is still a lack of evidence from clinical trials in China. We investigated whether S-ICD implantation in the Chinese population is safe and feasible and should be promoted in the future.MethodsConsecutive patients undergoing S-ICD implantation at our center were enrolled in this retrospective study. Data were collected within the median follow-up period of 554 days. Data concerning patient selection, implantation procedures, complications, and episodes of shock were analyzed.ResultsIn total, 70.2% of all 47 patients (median age = 39 years) were included for secondary prevention of SCD with different etiologies. Vector screening showed that 98% of patients were with > 1 appropriate vector in all postures. An intraoperative defibrillation test was not performed on six patients because of the high risk of disease deterioration, while all episodes of ventricular fibrillation induced post implantation were terminated by one shock. As expected, no severe complications (e.g., infection and device-related complications) were observed, except for one case of delayed healing of the incision. Overall, 15 patients (31.9%) experienced appropriate shocks (AS) with all episodes terminated by one shock. Two patients (4.3%) experienced inappropriate shocks (IAS) due to noise oversensing, resulting in a high Kaplan-Meier IAS-free rate of 95.7%.ConclusionBased on appropriate patient selection and standardized implantation procedures, this real-world study confirmed the safety and efficacy of S-ICD in Chinese patients, indicating that it may help to promote the prevention of SCD in China.
引用
收藏
页码:462 / 469
页数:8
相关论文
共 39 条
[11]   Intraoperative Defibrillation Testing of Subcutaneous Implantable Cardioverter-Defibrillator Systems-A Simple Issue? [J].
Frommeyer, Gerrit ;
Zumhagen, Sven ;
Dechering, Dirk G. ;
Larbig, Robert ;
Bettin, Markus ;
Loeher, Andreas ;
Koebe, Julia ;
Reinke, Florian ;
Eckardt, Lars .
JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2016, 5 (03)
[12]   Primary Results From the Understanding Outcomes With the S-ICD in Primary Prevention Patients With Low Ejection Fraction (UNTOUCHED) Trial [J].
Gold, Michael R. ;
Lambiase, Pier D. ;
El-Chami, Mikhael F. ;
Knops, Reinoud E. ;
Aasbo, Johan D. ;
Bongiorni, Maria Grazia ;
Russo, Andrea M. ;
Deharo, Jean-Claude ;
Burke, Martin C. ;
Dinerman, Jay ;
Barr, Craig S. ;
Shaik, Naushad ;
Carter, Nathan ;
Stoltz, Thomas ;
Stein, Kenneth M. ;
Brisben, Amy J. ;
Boersma, Lucas V. A. .
CIRCULATION, 2021, 143 (01) :7-17
[13]   A real-world experience of subcutaneous and transvenous implantable cardiac defibrillators-comparison with the PRAETORIAN study [J].
Khanra, Dibbendhu ;
Hamid, Abdul ;
Patel, Peysh ;
Tomson, John ;
Abdalla, Ahmed ;
Khan, Nasrin ;
Dowd, Rory ;
Chandan, Nakul ;
Osagie, Christopher ;
Jinadu, Tomilola ;
Velu, Selvakumar ;
Arya, Anita ;
Spencer, Charles ;
Barr, Craig ;
Petkar, Sanjiv .
JOURNAL OF ARRHYTHMIA, 2022, 38 (02) :199-212
[14]   Efficacy and Safety of Appropriate Shocks and Antitachycardia Pacing in Transvenous and Subcutaneous Implantable Defibrillators: Analysis of All Appropriate Therapy in the PRAETORIAN Trial [J].
Knops, Reinoud E. ;
van der Stuijt, Willeke ;
Delnoy, Peter Paul H. M. ;
Boersma, Lucas V. A. ;
Kuschyk, Juergen ;
El-Chami, Mikhael F. ;
Bonnemeier, Hendrik ;
Behr, Elijah R. ;
Brouwer, Tom F. ;
Kaab, Stefan ;
Mittal, Suneet ;
Quast, Anne-Floor B. E. ;
Smeding, Lonneke ;
Tijssen, Jan G. P. ;
Bijsterveld, Nick R. ;
Richter, Sergio ;
Brouwer, Marc A. ;
de Groot, Joris R. ;
Kooiman, Kirsten M. ;
Lambiase, Pier D. ;
Neuzil, Petr ;
Vernooy, Kevin ;
Alings, Marco ;
Betts, Timothy R. ;
Bracke, Frank A. L. E. ;
Burke, Martin C. ;
de Jong, Jonas S. S. G. ;
Wright, David J. ;
Jansen, Ward P. J. ;
Whinnet, Zachary I. ;
Nordbeck, Peter ;
Knaut, Michael ;
Philbert, Berit T. ;
van Opstal, Jurren M. ;
Chicos, Alexandru B. ;
Allaart, Cornelis P. ;
Borger van der Burg, Alida E. ;
Clancy, Jude F. ;
Dizon, Jose M. ;
Miller, Marc A. ;
Nemirovsky, Dmitry ;
Surber, Ralf ;
Upadhyay, Gaurav A. ;
Weiss, Raul ;
de Weger, Anouk ;
Wilde, Arthur A. M. ;
Olde Nordkamp, Louise R. A. .
CIRCULATION, 2022, 145 (05) :321-329
[15]   Subcutaneous or Transvenous Defibrillator Therapy [J].
Knops, Reinoud E. ;
Nordkamp, Louise R. A. Olde ;
Delnoy, Peter-Paul H. M. ;
Boersma, Lucas V. A. ;
Kuschyk, Juergen ;
El-Chami, Mikhael F. ;
Bonnemeier, Hendrik ;
Behr, Elijah R. ;
Brouwer, Tom F. ;
Kaab, Stefan ;
Mittal, Suneet ;
Quast, Anne-Floor B. E. ;
Smeding, Lonneke ;
van der Stuijt, Willeke ;
de Weger, Anouk ;
de Wilde, Koen C. ;
Bijsterveld, Nick R. ;
Richter, Sergio ;
Brouwer, Marc A. ;
de Groot, Joris R. ;
Kooiman, Kirsten M. ;
Lambiase, Pier D. ;
Neuzil, Petr ;
Vernooy, Kevin ;
Alings, Marco ;
Betts, Tim R. ;
Bracke, Frank A. L. E. ;
Burke, Martin C. ;
de Jong, Jonas S. S. G. ;
Wright, David J. ;
Tijssen, Jan G. P. ;
Wilde, Arthur A. M. .
NEW ENGLAND JOURNAL OF MEDICINE, 2020, 383 (06) :526-536
[16]   The learning curve associated with the introduction of the subcutaneous implantable defibrillator [J].
Knops, Reinoud E. ;
Brouwer, Tom F. ;
Barr, Craig S. ;
Theuns, Dominic A. ;
Boersma, Lucas ;
Weiss, Raul ;
Neuzil, Petr ;
Scholten, Marcoen ;
Lambiase, Pier D. ;
Leon, Angel R. ;
Hood, Margaret ;
Jones, Paul W. ;
Wold, Nicholas ;
Grace, Andrew A. ;
Nordkamp, Louise R. A. Olde ;
Burke, Martin C. .
EUROPACE, 2016, 18 (07) :1010-1015
[17]   Risk Factors and Temporal Trends of Complications Associated With Transvenous Implantable Cardiac Defibrillator Leads [J].
Koneru, Jayanthi N. ;
Jones, Paul W. ;
Hammill, Eric F. ;
Wold, Nicholas ;
Ellenbogen, Kenneth A. .
JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2018, 7 (10)
[18]   Inappropriate subcutaneous implantable cardioverter-defibrillator shocks due to T-wave oversensing can be prevented: Implications for management [J].
Kooiman, Kirsten M. ;
Knops, Reinoud E. ;
Nordkamp, Louise Olde ;
Wilde, Arthur A. M. ;
de Groot, Joris R. .
HEART RHYTHM, 2014, 11 (03) :426-434
[19]   Subcutaneous implantable cardioverter-defibrillators: long-term results of the EFFORTLESS study [J].
Lambiase, Pier D. ;
Theuns, Dominic A. ;
Murgatroyd, Francis ;
Barr, Craig ;
Eckardt, Lars ;
Neuzil, Petr ;
Scholten, Marcoen ;
Hood, Margaret ;
Kuschyk, Jurgen ;
Brisben, Amy J. ;
Carter, Nathan ;
Stivland, Timothy M. ;
Knops, Reinoud ;
Boersma, Lucas V. A. .
EUROPEAN HEART JOURNAL, 2022, 43 (21) :2037-2050
[20]   Worldwide experience with a totally subcutaneous implantable defibrillator: early results from the EFFORTLESS S-ICD Registry [J].
Lambiase, Pier D. ;
Barr, Craig ;
Theuns, Dominic A. M. J. ;
Knops, Reinoud ;
Neuzil, Petr ;
Johansen, Jens Brock ;
Hood, Margaret ;
Pedersen, Susanne ;
Kaeaeb, Stefan ;
Murgatroyd, Francis ;
Reeve, Helen L. ;
Carter, Nathan ;
Boersma, Lucas .
EUROPEAN HEART JOURNAL, 2014, 35 (25) :1657-+