Calibration-free blood pressure estimation based on a convolutional neural network

被引:0
|
作者
Cho, Jinwoo [1 ]
Shin, Hangsik [2 ,5 ]
Choi, Ahyoung [3 ,4 ]
机构
[1] Bud on Co Ltd, Seoul, South Korea
[2] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Digital Med, Seoul, South Korea
[3] Gachon Univ, Dept AI Software, Seongnam, South Korea
[4] Gachon Univ, Dept AI Software, Seongnam 13120, South Korea
[5] Univ Ulsan, Asan Med Ctr, Dept Digital Med, Coll Med, Seoul 05505, South Korea
基金
新加坡国家研究基金会;
关键词
blood pressure estimation; convolutional neural network; electrocardiogram; photoplethysmogram; wearable environment; PULSE TRANSIT-TIME; WAVE; VARIABILITY; DISPERSION; DURATION;
D O I
10.1111/psyp.14480
中图分类号
B84 [心理学];
学科分类号
04 ; 0402 ;
摘要
In this study, we conducted research on a deep learning-based blood pressure (BP) estimation model suitable for wearable environments. To measure BP while wearing a wearable watch, it needs to be considered that computing power for signal processing is limited and the input signals are subject to noise interference. Therefore, we employed a convolutional neural network (CNN) as the BP estimation model and utilized time-series electrocardiogram (ECG) and photoplethysmogram (PPG) signals, which are quantifiable in a wearable context. We generated periodic input signals and used differential and thresholding methods to decrease noise in the preprocessing step. We then applied a max-pooling technique with filter sizes of 2 x 1 and 5 x 1 within a 3-layer convolutional neural network to estimate BP. Our method was trained, validated, and tested using 2.4 million data samples from 49 patients in the intensive care unit. These samples, totaling 3.1 GB were obtained from the publicly accessible MIMIC database. As a result of a test with 480,000 data samples, the average root mean square error in BP estimation was 3.41, 5.80, and 2.78 mm Hg in the prediction of pulse pressure, systolic BP (SBP), and diastolic BP (DBP), respectively. The cumulative error percentage less than 5 mm Hg was 68% and 93% for SBP and DBP, respectively. In addition, the cumulative error percentage less than 15 mm Hg was 98% and 99% for SBP and DBP. Subsequently, we evaluated the impact of changes in input signal length (1 cycle vs. 30 s) and the introduction of noise on BP estimation results. The experimental results revealed that the length of the input signal did not significantly affect the performance of CNN-based analysis. When estimating BP using noise-added ECG signals, the mean absolute error (MAE) for SBP and DBP was 9.72 and 6.67 mm Hg, respectively. Meanwhile, when using noise-added PPG signals, the MAE for SBP and DBP was 26.85 and 14.00 mm Hg, respectively. Therefore, this study confirmed that using ECG signals rather than PPG signals is advantageous for noise reduction in a wearable environment. Besides, short sampling frames without calibration can be effective as input signals. Furthermore, it demonstrated that using a model suitable for information extraction rather than a specialized deep learning model for sequential data can yield satisfactory results in BP estimation.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Calibration-Free Cuffless Blood Pressure Estimation Based on a Population With a Diverse Range of Age and Blood Pressure
    Yamanaka, Syunsuke
    Morikawa, Koji
    Morita, Hiroshi
    Huh, Ji Young
    Yamamura, Osamu
    FRONTIERS IN MEDICAL TECHNOLOGY, 2021, 3
  • [2] A PPG-Based Calibration-Free Cuffless Blood Pressure Estimation Method Using Cardiovascular Dynamics
    Samimi, Hamed
    Dajani, Hilmi R.
    SENSORS, 2023, 23 (08)
  • [3] Blind, Cuff-less, Calibration-Free and Continuous Blood Pressure Estimation using Optimized Inductive Group Method of Data Handling
    Mohebbian, Mohammad Reza
    Anh Dinh
    Wahid, Khan
    Alam, Mohammad Sami
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2020, 57
  • [4] Non-Contact Calibration-Free Blood Pressure Estimation Method Using Dual Radar
    Zheng, Zhi
    Wang, Bo
    Guo, Yongxin
    2022 IEEE MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE (IMBIOC), 2022, : 186 - 188
  • [5] Oscillometry-Based Blood Pressure Estimation Using Convolutional Neural Networks
    Choi, Minho
    Lee, Sang-Jin
    IEEE ACCESS, 2022, 10 : 56813 - 56822
  • [6] Combining Local PWV and Quantified Arterial Changes for Calibration-Free Cuffless Blood Pressure Estimation: A Clinical Validation
    Guo, Cheng-Yan
    Huang, Chi-Hung
    Chang, Chia-Chi
    Wang, Kuan-Jen
    Hsieh, Tung-Li
    IEEE SENSORS JOURNAL, 2023, 23 (01) : 658 - 668
  • [7] Cuff-less Calibration-free Blood Pressure Estimation under Ambulatory Environment using Pulse Wave Velocity and Photoplethysmogram Signals
    Sanuki, Haruyuki
    Rui Fukui
    Inajima, Tsukasa
    Warisawa, Shin'ichi
    PROCEEDINGS OF THE 10TH INTERNATIONAL JOINT CONFERENCE ON BIOMEDICAL ENGINEERING SYSTEMS AND TECHNOLOGIES, VOL 4: BIOSIGNALS, 2017, : 42 - 48
  • [8] Fully convolutional neural network and PPG signal for arterial blood pressure waveform estimation
    Zhou, Yongan
    Tan, Zhi
    Liu, Yuhong
    Cheng, Haibo
    PHYSIOLOGICAL MEASUREMENT, 2023, 44 (07)
  • [9] Cuff-less Blood Pressure Measurement Based on Deep Convolutional Neural Network
    Liu, ZengDing
    Miao, Fen
    Wang, Ruxin
    Liu, Jikui
    Wen, Bo
    Li, Ye
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 3775 - 3778
  • [10] Estimating Systolic Blood Pressure Using Convolutional Neural Networks
    Rastegar, Solmaz
    Gholamhosseini, Hamid
    Lowe, Andrew
    Mehdipour, Farhad
    Linden, Maria
    PHEALTH 2019, 2019, 261 : 143 - 149