Vortex shedding characteristics and hydrodynamic forces of stationary and elastically mounted side-by-side cylinders fitted with small diameter control rods

被引:4
|
作者
Hammad, Omar S. [1 ]
Mohany, Atef [1 ]
机构
[1] Ontario Tech Univ, Fluid Struct Interact & Noise Control Lab, 2000 Simcoe St N, Oshawa, ON L1H 7K4, Canada
关键词
Bluff bodies; Vortex shedding; Flow-induced vibration; Hydrodynamic forces; Suppression; Flow control; EXCITED ACOUSTIC-RESONANCE; CIRCULAR-CYLINDERS; INDUCED VIBRATION; LOW-MASS; WAKE PATTERNS; FLOW; SUPPRESSION; EVOLUTION;
D O I
10.1016/j.jfluidstructs.2023.103908
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Vortex shedding behind bluff bodies can induce noise and vibration problems when it engages in a feedback cycle of oscillations with an acoustic or structural mode. Therefore, several passive and active flow control techniques have been developed to suppress vortex shedding behind a single bluff body. However, less attention was given to the case of multiple bluff bodies in cross-flow. Therefore, in this paper, a numerical investigation is performed to study the effect of adding small diameter control rods in the vicinity of two side-by-side cylinders on the vortex shedding characteristics, the hydrodynamic fluid forces, as well as the suppression of vortex-induced vibration. The simulations are conducted at a Reynolds number of Re = 200 and the side-by-side cylinders have a spacing ratio of T* = 2.5. The number of control rods and their angular positions around the main cylinders are varied. Fitting the side-by-side cylinders with control rods has resulted in three different flow regimes compared to the base case with no control rods. These flow regimes depend on the angular positions of the control rods and they are classified as; bistable flow, stable biased flow, and merged wake flow regimes. The stable biased flow regime has resulted in the maximum reduction of the fluctuating lift coefficient of the side-by-side cylinders, especially when the control rods are placed at & theta; = 135 degrees from the flow stagnation point. Increasing the number of control rods around the cylinders has further reduced the fluctuating lift coefficient and produced a more symmetric wake at the rod angles which produce the stable biased flow, and the merged wake flow regimes. The vortex-induced vibration of the side-byside cylinders is investigated when the control rods are placed at the angular position that results in a stable biased flow regime. It is revealed that fitting the cylinders with control rods at an angular position of & theta; = 135 degrees has resulted in reducing the vibration amplitude over the whole range of the simulated reduced flow velocities, which makes this technique a viable one to control the vortex shedding and the vortex-induced vibration of side-by-side cylinders.
引用
收藏
页数:22
相关论文
共 33 条
  • [1] Control of vortex shedding from two side-by-side cylinders using a pair of tangential jets
    Yuan, Fangyang
    Cao, Yang
    Tu, Chengxu
    Lin, Jianzhong
    AIP ADVANCES, 2020, 10 (10)
  • [2] Vortex-induced vibration of two elastically coupled cylinders in side-by-side arrangement
    Cui, Zhendong
    Zhao, Ming
    Teng, Bin
    JOURNAL OF FLUIDS AND STRUCTURES, 2014, 44 : 270 - 291
  • [3] Vortex shedding in the flow around two side-by-side circular cylinders of different diameters
    Qiu, Xiang
    Bi, Zhen-xiao
    Luo, Jian-ping
    Liu, Yu-lu
    JOURNAL OF HYDRODYNAMICS, 2017, 29 (03) : 470 - 478
  • [4] Vortex shedding in the flow around two side-by-side circular cylinders of different diameters
    邱翔
    毕贞晓
    罗剑平
    刘宇陆
    JournalofHydrodynamics, 2017, 29 (03) : 470 - 478
  • [5] Vortex shedding in the flow around two side-by-side circular cylinders of different diameters
    Xiang Qiu
    Zhen-xiao Bi
    Jian-ping Luo
    Yu-lu Liu
    Journal of Hydrodynamics, 2017, 29 : 470 - 478
  • [6] Vortex induced vibration and vortex shedding characteristics of two side-by-side circular cylinders of different diameters in close proximity in steady flow
    Rahmanian, Mehran
    Cheng, Liang
    Zhao, Ming
    Zhou, Tongming
    JOURNAL OF FLUIDS AND STRUCTURES, 2014, 48 : 260 - 279
  • [7] Numerical study on hydrodynamic interaction characteristics of vortex-induced vibration of two side-by-side cylinders near the wall
    Yin, Pandeng
    Xin, Jianjian
    Shi, Fulong
    Li, Yafei
    Liu, Xiangyu
    Shu, Liang
    OCEAN ENGINEERING, 2024, 308
  • [8] Characteristics of the wake flow control behind two side-by-side circular cylinders by a small cylinder
    Zhang, HJ
    Su, ZD
    Yin, ZQ
    RECENT ADVANCES IN FLUID MECHANICS, 2004, : 368 - 371
  • [9] Lock-on characteristics behind two side-by-side cylinders of diameter ratio two at small gap ratio
    Petry Y. R. Lee
    Wei-Ting Lu
    Shy-Tsin Chou
    Cheng-Hsiung Kuo
    Experiments in Fluids, 2012, 53 : 891 - 908
  • [10] Lock-on characteristics behind two side-by-side cylinders of diameter ratio two at small gap ratio
    Lee, Petry Y. R.
    Lu, Wei-Ting
    Chou, Shy-Tsin
    Kuo, Cheng-Hsiung
    EXPERIMENTS IN FLUIDS, 2012, 53 (04) : 891 - 908