Dosimetric comparison of pencil beam scanning proton therapy with or without multi-leaf collimator versus volumetric-modulated arc therapy for treatment of malignant glioma

被引:2
|
作者
Miyata, Junya [1 ,2 ]
Tominaga, Yuki [1 ,3 ]
Kondo, Kazuto [2 ]
Sonoda, Yasuaki [2 ]
Hanazawa, Hideki [4 ]
Sakai, Mami [4 ]
Itasaka, Satoshi [4 ]
Oita, Masataka [5 ]
Kuroda, Masahiro [6 ]
机构
[1] Okayama Univ, Grad Sch Interdisciplinary Sci & Engn Hlth Syst, Okayama, Japan
[2] Kurashiki Cent Hosp, Dept Radiol Technol, Kurashiki, Okayama, Japan
[3] Osaka Proton Therapy Clin, Dept Radiotherapy, Med Co Hakuhokai, Osaka, Osaka, Japan
[4] Kurashiki Cent Hosp, Dept Radiat Oncol, Kurashiki, Okayama, Japan
[5] Okayama Univ, Fac Interdisciplinary Sci & Engn Hlth Syst, 1-1 Tsushimanaka,3 Chome,Kita Ku, Okayama, Okayama 7008530, Japan
[6] Okayama Univ, Grad Sch Hlth Sci, Okayama, Japan
关键词
Pencil beam scanning; Intensity-modulated proton therapy; Multi-leaf collimator; Volumetric-modulated arc therapy; Glioma; APERTURE SYSTEM; NORMAL TISSUE; RADIOTHERAPY; HEAD; DELINEATION; GUIDELINE; ADULTS; ORGANS; BRAIN; RISK;
D O I
10.1016/j.meddos.2023.01.008
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
This study aimed to examine the dosimetric effect of intensity-modulated proton therapy (IMPT) with a multi-leaf collimator (MLC) in treating malignant glioma. We compared the dose distribution of IMPT with or without MLC (IMPTMLC + or IMPTMLC-, respectively) using pencil beam scanning and volumetric -modulated arc therapy (VMAT) in simultaneous integrated boost (SIB) plans for 16 patients with malig-nant gliomas. High-and low-risk target volumes were assessed using D 2% , V 90% , V 95% , homogeneity index (HI), and conformity index (CI). Organs at risk (OARs) were evaluated using the average dose (Dmean) and D 2% . Furthermore, the dose to the normal brain was evaluated using from V5Gy to V40Gy at 5 Gy intervals. There were no significant differences among all techniques regarding V 90% , V 95% , and CI for the targets. HI and D 2% for IMPTMLC + and IMPTMLC-were significantly superior to those for VMAT ( p < 0.01). The Dmean and D 2% of all OARs for IMPTMLC + were equivalent or superior to those of other techniques. Regarding the normal brain, there was no significant difference in V40Gy among all techniques whereas V5Gy to V35Gy in IMPTMLC + were significantly smaller than those in IMPTMLC-(with differences ranging from 0.45% to 4.80%, p < 0.05) and VMAT (with differences ranging from 6.85% to 57.94%, p < 0.01). IMPTMLC + could reduce the dose to OARs, while maintaining target coverage compared to IMPTMLC-and VMAT in treating malignant glioma.(c) 2023 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:105 / 112
页数:8
相关论文
共 50 条
  • [41] Dosimetric analysis of intensity-modulated radiation therapy and volumetric-modulated arc therapy in comparison with conventional box technique in the treatment of carcinoma cervix: An impact of prosthetic implant
    Bhushan, Manindra
    Tripathi, Deepak
    Yadav, Girigesh
    Kumar, Lalit
    Chowdhary, Rahul Lal
    Pahuja, Anjali K.
    Suhail, Mahamood
    Mitra, Swarupa
    Gairola, Munish
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2022, 18 (06) : 1504 - 1512
  • [42] From plan to delivery: Machine learning based positional accuracy prediction of multi-leaf collimator and estimation of delivery effect in volumetric modulated arc therapy
    Qiu, Minmin
    Zhong, Jiajian
    Xiao, Zhenhua
    Deng, Yongjin
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (09):
  • [43] Deep learning-based detection and classification of multi-leaf collimator modeling errors in volumetric modulated radiation therapy
    Nakamura, Sae
    Sakai, Madoka
    Ishizaka, Natsuki
    Mayumi, Kazuki
    Kinoshita, Tomotaka
    Akamatsu, Shinya
    Nishikata, Takayuki
    Tanabe, Shunpei
    Nakano, Hisashi
    Tanabe, Satoshi
    Takizawa, Takeshi
    Yamada, Takumi
    Sakai, Hironori
    Kaidu, Motoki
    Sasamoto, Ryuta
    Ishikawa, Hiroyuki
    Utsunomiya, Satoru
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023,
  • [44] Dosimetric comparison of volumetric-modulated arc therapy and intensity-modulated radiation therapy in patients with cervical cancer: a meta-analysis
    Bai, Wei
    Kou, Changgui
    Yu, Weiying
    Li, Yuanyuan
    Hua, Wanqing
    Yu, Lei
    Wang, Jianfeng
    ONCOTARGETS AND THERAPY, 2018, 11 : 7179 - 7186
  • [45] Comparison of sequential versus simultaneous integrated boost of volumetric modulated arc therapy in treatment of oropharyngeal carcinoma
    Kachhwaha, Avni
    Tiwari, Ramakant
    Gayen, Sanjib
    Manna, Sumanta
    Solanki, Akanksha
    Devnani, Bharti
    Pareek, Puneet
    CANCER TREATMENT AND RESEARCH COMMUNICATIONS, 2023, 36
  • [46] Dose distribution effects of spot-scanning proton beam therapy equipped with a multi-leaf collimator for pediatric brain tumors
    Fukumitsu, Nobuyoshi
    Yamashita, Tomohiro
    Mima, Masayuki
    Demizu, Yusuke
    Suzuki, Takeshi
    Soejima, Toshinori
    ONCOLOGY LETTERS, 2021, 22 (02)
  • [47] Single arc volumetric-modulated arc therapy is sufficient for nasopharyngeal carcinoma: a dosimetric comparison with dual arc VMAT and dynamic MLC and step-and-shoot intensity-modulated radiotherapy
    Ning, Zhong-Hua
    Mu, Jin-Ming
    Jin, Jian-Xue
    Li, Xiao-Dong
    Li, Qi-Lin
    Gu, Wen-Dong
    Huang, Jin
    Han, Yang
    Pei, Hong-Lei
    RADIATION ONCOLOGY, 2013, 8
  • [48] Intensity-modulated proton therapy versus volumetric-modulated ARC therapy in patients with nasopharyngeal carcinoma: A long-term, multicenter cohort study
    Wu, Ching-Nung
    Wang, Jung-Der
    Chen, Wei-Chih
    Lin, Chung-Ying
    Chiu, Tai-Jan
    Yang, Yao-Hsu
    Chang, Joseph Tung-Chieh
    Luo, Sheng-Dean
    Wang, Yu-Ming
    RADIOTHERAPY AND ONCOLOGY, 2025, 202
  • [49] Dosimetric comparison of complete block in ovarian protection between helical tomotherapy and volumetric-modulated arc therapy for cervical cancer
    Liu, Xianfeng
    Wu, Furong
    Jin, Fu
    Sun, Fu
    Li, Qicheng
    Guo, Mingfang
    Zhao, Xiujuan
    Guo, Qishuai
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2022, 15 (01) : 11 - 16
  • [50] Dosimetric comparison of short and full arc in spinal PTV in volumetric-modulated arc therapy-based craniospinal irradiation
    Sarkar, Biplab
    Munshi, Anusheel
    Ganesh, Tharmarnadar
    Manikandan, Arjunan
    Mohanti, Bidhu K.
    MEDICAL DOSIMETRY, 2020, 45 (01) : 1 - 6