Dosimetric comparison of pencil beam scanning proton therapy with or without multi-leaf collimator versus volumetric-modulated arc therapy for treatment of malignant glioma

被引:2
|
作者
Miyata, Junya [1 ,2 ]
Tominaga, Yuki [1 ,3 ]
Kondo, Kazuto [2 ]
Sonoda, Yasuaki [2 ]
Hanazawa, Hideki [4 ]
Sakai, Mami [4 ]
Itasaka, Satoshi [4 ]
Oita, Masataka [5 ]
Kuroda, Masahiro [6 ]
机构
[1] Okayama Univ, Grad Sch Interdisciplinary Sci & Engn Hlth Syst, Okayama, Japan
[2] Kurashiki Cent Hosp, Dept Radiol Technol, Kurashiki, Okayama, Japan
[3] Osaka Proton Therapy Clin, Dept Radiotherapy, Med Co Hakuhokai, Osaka, Osaka, Japan
[4] Kurashiki Cent Hosp, Dept Radiat Oncol, Kurashiki, Okayama, Japan
[5] Okayama Univ, Fac Interdisciplinary Sci & Engn Hlth Syst, 1-1 Tsushimanaka,3 Chome,Kita Ku, Okayama, Okayama 7008530, Japan
[6] Okayama Univ, Grad Sch Hlth Sci, Okayama, Japan
关键词
Pencil beam scanning; Intensity-modulated proton therapy; Multi-leaf collimator; Volumetric-modulated arc therapy; Glioma; APERTURE SYSTEM; NORMAL TISSUE; RADIOTHERAPY; HEAD; DELINEATION; GUIDELINE; ADULTS; ORGANS; BRAIN; RISK;
D O I
10.1016/j.meddos.2023.01.008
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
This study aimed to examine the dosimetric effect of intensity-modulated proton therapy (IMPT) with a multi-leaf collimator (MLC) in treating malignant glioma. We compared the dose distribution of IMPT with or without MLC (IMPTMLC + or IMPTMLC-, respectively) using pencil beam scanning and volumetric -modulated arc therapy (VMAT) in simultaneous integrated boost (SIB) plans for 16 patients with malig-nant gliomas. High-and low-risk target volumes were assessed using D 2% , V 90% , V 95% , homogeneity index (HI), and conformity index (CI). Organs at risk (OARs) were evaluated using the average dose (Dmean) and D 2% . Furthermore, the dose to the normal brain was evaluated using from V5Gy to V40Gy at 5 Gy intervals. There were no significant differences among all techniques regarding V 90% , V 95% , and CI for the targets. HI and D 2% for IMPTMLC + and IMPTMLC-were significantly superior to those for VMAT ( p < 0.01). The Dmean and D 2% of all OARs for IMPTMLC + were equivalent or superior to those of other techniques. Regarding the normal brain, there was no significant difference in V40Gy among all techniques whereas V5Gy to V35Gy in IMPTMLC + were significantly smaller than those in IMPTMLC-(with differences ranging from 0.45% to 4.80%, p < 0.05) and VMAT (with differences ranging from 6.85% to 57.94%, p < 0.01). IMPTMLC + could reduce the dose to OARs, while maintaining target coverage compared to IMPTMLC-and VMAT in treating malignant glioma.(c) 2023 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:105 / 112
页数:8
相关论文
共 50 条
  • [21] Dose distribution of intensity-modulated proton therapy with and without a multi-leaf collimator for the treatment of maxillary sinus cancer: a comparative effectiveness study
    Soichi Sugiyama
    Kuniaki Katsui
    Yuki Tominaga
    Takahiro Waki
    Norihisa Katayama
    Hidenobu Matsuzaki
    Shin Kariya
    Masahiro Kuroda
    Kazunori Nishizaki
    Susumu Kanazawa
    Radiation Oncology, 14
  • [22] Minimum requirements for commissioning and long-term quality assurance of Elekta multi-leaf collimator for volumetric modulated arc therapy
    Tatsumi D.
    Nakada R.
    Yomoda A.
    Ishii K.
    Tsutsumi S.
    Inoue M.
    Ichida T.
    Hosono M.N.
    Miki Y.
    Radiological Physics and Technology, 2013, 6 (1) : 98 - 106
  • [23] Treatment planning comparison of volumetric modulated arc therapy employing a dual-layer stacked multi-leaf collimator and helical tomotherapy for cervix uteri
    Panda, S.
    Swamidas, J.
    Chopra, S.
    Mangaj, A.
    Fogliata, A.
    Kupelian, P.
    Agarwal, J. P.
    Cozzi, L.
    RADIATION ONCOLOGY, 2020, 15 (01)
  • [24] Gantry-based pencil beam scanning proton therapy for uveal melanoma: IMPT versus proton arc therapy
    Qi, Hang
    Hu, Lei
    Huang, Sheng
    Lee, Yen-Po
    Yu, Francis
    Chen, Qing
    Yang, Yunjie
    Kang, Minglei
    Zhai, Huifang
    Vermeulen, Milo
    Shim, Andy
    Park, Peter
    Ding, Xuanfeng
    Zhou, Jun
    Abramson, David H.
    Francis, Jasmine H.
    Simone, Charles B.
    Barker, Christopher A.
    Lin, Haibo
    RADIATION ONCOLOGY, 2025, 20 (01)
  • [25] Volumetric-modulated arc therapy for oropharyngeal carcinoma: A dosimetric and delivery efficiency comparison with static-field IMRT
    Dai, Xiaofang
    Zhao, Yingchao
    Liang, Zhiwen
    Dassarath, Meera
    Wang, Lu
    Jin, Lihui
    Chen, Lili
    Dong, James
    Price, Robert A.
    Ma, C-M.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (01): : 54 - 59
  • [26] Pencil beam scanning proton therapy vs rotational arc radiation therapy: A treatment planning comparison for postoperative oropharyngeal cancer
    Apinorasethkul, Ontida
    Kirk, Maura
    Teo, Kevin
    Swisher-McClure, Samuel
    Lukens, John N.
    Lin, Alexander
    MEDICAL DOSIMETRY, 2017, 42 (01) : 7 - 11
  • [27] Dosimetric Comparison of Four Volumetric-Modulated Arc Therapy Beam Arrangements Utilized for Hippocampal-Sparing Whole-Brain Radiation Therapy
    Prado, Alejandro
    Isabel Milanes, Ana
    Cabello, Eduardo
    Diaz, Raul
    Ferrando, Alejandro
    Pozo, Gustavo
    Leonor, Mario
    Manzano, Marta
    JOURNAL OF MEDICAL PHYSICS, 2019, 44 (01) : 1 - 8
  • [28] Dosimetric comparison of magnetic resonance-guided radiation therapy, intensity-modulated proton therapy and volumetric-modulated arc therapy for distal esophageal cancer
    Barsky, Andrew R.
    George, Jerry
    Wroe, Andrew J.
    Mittauer, Kathryn E.
    Kaiser, Adeel
    Herrera, Roberto
    Yu, Jen
    Gutierrez, Alonso N.
    Alvarez, Diane
    McCulloch, James
    Kasper, Michael E.
    Mehta, Minesh P.
    Chuong, Michael D.
    MEDICAL DOSIMETRY, 2024, 49 (02) : 121 - 126
  • [29] The dosimetric enhancement of GRID profiles using an external collimator in pencil beam scanning proton therapy
    Smith, Blake R.
    Nelson, Nicholas P.
    Geoghegan, Theodore J.
    Patwardhan, Kaustubh A.
    Hill, Patrick M.
    Yu, Jen
    Gutierrez, Alonso N.
    Allen, Bryan G.
    Hyer, Daniel E.
    MEDICAL PHYSICS, 2022, 49 (04) : 2684 - 2698
  • [30] Utility of a patient-specific aperture collimator and multi-leaf collimator in line scanning proton therapy
    Ko, Mincheol
    Jeon, Chanil
    Ahn, Sung Hwan
    Han, Youngyih
    Chung, Kwangzoo
    Cho, Sungkoo
    Jo, Kwanghyun
    Shin, Eun Hyuk
    Lee, Sehyoung
    Lee, Woojin
    Oh, Yoonjin
    Kim, Juhye
    Kang, Seokyoon
    Park, Hee Chul
    Lee, Kisung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2024, 85 (09) : 751 - 762