Insulation Reinforcement for Cable Connector of CRH2 Electric Multiple Unit Under Standard Lightning Impulse Voltage

被引:1
作者
Ma, Jianqiao [1 ]
Ma, Lei [1 ]
Yang, Guangze [1 ]
Wu, Youqiang [1 ]
机构
[1] Lanzhou Jiaotong Univ, Sch Automat & Elect Engn, Dept Power Engn, Lanzhou 730070, Peoples R China
关键词
Insulation; Electric fields; High-voltage techniques; Standards; Discharges (electric); Lightning; Electrodes; Cable connector (Cc); electric field calculation; image processing; orthogonal test; ultraviolet imaging technology; FLASHOVER; PERFORMANCE; SIMULATION; DESIGN;
D O I
10.1109/TTE.2022.3210713
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In order to improve the insulation capacity of cable connector (Cc) in the high voltage equipment box (Hveb), this article proposes an optimization scheme that does not change the size of the Hveb and the structure of Cc fittings. In this article, the change in the impulse voltage withstand value of Cc after installing insulating sheath was verified by the lightning impulse flashover test. Based on the finite-element software and the structure of Cc fittings, a special shaped shielding ring (Sr) was designed to adjust the partial area where the electric field intensity are concentrated. Besides, the optimal parameters of the Sr under different working conditions were determined by the orthogonal design. Finally, utilizing ultraviolet (UV) imaging technology and image processing method, the discharge intensity of Cc fittings were characterized. The results demonstrate that with the combination of insulation measures, the impulse voltage withstand value of Cc can be increased from 155 to 235 kV. The maximum electric field strength on the surface of bolts and metal electrode can be reduced by 57.8% and 72%; UV discharge facular area had an exponential relationship with the applied voltage, the initial discharge voltage of Cc can increase by 243% after installing the Sr.
引用
收藏
页码:1683 / 1697
页数:15
相关论文
共 36 条
[1]   Silicone rubber aging in electrolyzed aqueous salt environments [J].
Bleszynski, M. ;
Kumosa, M. .
POLYMER DEGRADATION AND STABILITY, 2017, 146 :61-68
[2]   高速列车车顶高压设备电场仿真计算及金具结构优化 [J].
邓志祥 ;
彭宗仁 ;
尹桂来 .
高压电器, 2016, 52 (11) :149-156
[3]  
Doufene D., 2019, Australian Journal of Electrical and Electronics Engineering, V16, P149, DOI DOI 10.1080/1448837X.2019.1627740
[4]   Shape and electric performance improvement of an insulator string using particles swarm algorithm [J].
Doufene, Dyhia ;
Bouazabia, Slimane ;
Haddad, Abderrahmane .
IET SCIENCE MEASUREMENT & TECHNOLOGY, 2020, 14 (02) :198-205
[5]   Flashover of Insulators in a Wet Environment [J].
He, J. ;
Gorur, R. S. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (02) :1038-1044
[6]   Source Strength Impact Analysis on Polymer Insulator Flashover under Contaminated Conditions and a Comparison with Porcelain [J].
He, L. ;
Gorur, R. S. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (04) :2189-2195
[7]   Grounding Behavior and Optimization Analysis of Electric Multiple Units in High-Speed Railways [J].
Huang, Ke ;
Liu, Zhigang ;
Zhu, Feng ;
Deng, Yunchuan .
IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2021, 7 (01) :240-255
[8]   Current Impulse Velocity After the Air Gap Breakdown at Atmospheric Pressure [J].
Huang, Liyang ;
Zhang, Qi ;
Duan, Yantao ;
Chen, Hailin ;
Wang, Jianbao ;
Shi, Lihua ;
Gao, Cheng .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2020, 62 (02) :635-638
[9]  
Jiang T. Li, 2020, ELECT DRIVE LOCOMOTI, P87
[10]  
[姜晓锋 Jiang Xiaofeng], 2013, [铁道学报, Journal of the China Railway Society], V35, P30