Analysis of bisphenol-propane in dialyzer and its effect on human body

被引:0
作者
Yun, Chen [1 ,2 ,8 ]
He, Xiaofan [3 ]
Xie, Ting [2 ]
Chi-Wa, Ao-Ieong [4 ]
Li, Weilong [5 ]
Song, Zhuoheng [5 ]
Xiao, Mengyun [2 ]
Meng, Yu [2 ,6 ,7 ]
Hu, Bo [2 ,6 ,7 ]
Guan, Baozhang [2 ,6 ]
Yang, Lifeng [3 ]
Ye, Mingjun [2 ,6 ]
Zeng, Huiyi [2 ,6 ]
Morgera, Stanislao [1 ]
Kraemer, Bernhard [8 ]
Wolfganng [9 ]
Yin, Lianghong [2 ,6 ,7 ]
Luan, Shaodong [5 ]
Xu, Suhua [3 ]
Hocher, Berthold [8 ]
机构
[1] Charite Univ Med Berlin, Dept Nephrol, Campus Mitte, D-10117 Berlin, Germany
[2] Jinan Univ, Affiliated Hosp 1, Inst Nephrol & Blood Purificat, Guangzhou 510632, Peoples R China
[3] Guangdong Med Devices Qual Surveillance & Test In, Guangzhou 510663, Peoples R China
[4] Kiang Wu Hosp, Macau 820002, Peoples R China
[5] Shenzhen Longhua Dist Cent Hosp, Dept Nephrol, Shenzhen 518110, Peoples R China
[6] Jinan Univ, Affiliated Hosp 1, Inst Nephrol & Blood Purificat, Guangzhou 510632, Peoples R China
[7] Jinan Univ, Affiliated Hosp 5, Inst Nephrol & Blood Purificat, Heyuan Shenhe Peoples Hosp, Heyuan 517600, Peoples R China
[8] Heidelberg Univ, Univ Med Ctr Mannheim, Dept Med 5, Nephrol,Endocrinol,Rheumatol, D-68167 Heidelberg, Germany
[9] KfH Kuratoriumfuer Dialyse & Nierentransplantatio, Bildungszentrum, D-63263 Neu Isenburg, Germany
关键词
Bisphenol A; Hemodialysis; Extractables; Dialyzer; Risk Assessment; EXPOSURE; ASSAY; LAYER; FLUX;
D O I
10.1166/mex.2023.2327
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The effect of trace solvent bisphenol A (BPA) in polyether sulfone hollow fiber membrane EnttexTM-16LF (E60) (produced by 3 M) low-throughput dialyzer was tested in this study. Animal experiments were conducted to evaluate its genotoxicity, carcinogenicity, and teratogenicity upon chronic exposure. The dialyzer was operated at 200 mL/min and 400 mL/min and coupled with LC-20AT liquid chromatography to detect BPA, which showed that the BPA content was less than 5 mu g/kg/d at both flow rates. In animal experiments, the tolerable intake (T.I.) was calculated to be 0.5 mu g/kg/d. With hemodialysis three times per week, the average patient weight was calculated at 70 kg, and the average daily BPA exposure was 0.0306 mu g/kg/d. The risk of residual BPA was within the acceptable limit with polyether sulfone membrane EnttexTM-16LF (E60) hollow fiber dialyzer from 3 M, without inducing risk for disability, teratogenicity, or genotoxicity.
引用
收藏
页码:170 / 181
页数:12
相关论文
共 50 条
  • [41] The effect of bisphenol A on testicular steroidogenesis and its amelioration by quercetin: an in vivo and in silico approach
    Samova, Sanman
    Patel, Chirag N.
    Doctor, Hetal
    Pandya, Himanshu A.
    Verma, R. J.
    TOXICOLOGY RESEARCH, 2018, 7 (01) : 22 - 31
  • [42] Edible fungus degrade bisphenol A with no harmful effect on its fatty acid composition
    Zhang, Chengdong
    Li, Mingzhu
    Chen, Xiaoyan
    Li, Mingchun
    ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2015, 118 : 126 - 132
  • [43] Evaluation of DNA-damaging potential of bisphenol A and its selected analogs in human peripheral blood mononuclear cells (in vitro study)
    Mokra, Katarzyna
    Kuzminska-Surowaniec, Agnieszka
    Wozniak, Katarzyna
    Michalowicz, Jaromir
    FOOD AND CHEMICAL TOXICOLOGY, 2017, 100 : 62 - 69
  • [44] Simultaneous determination of bisphenol A and its chlorinated derivatives in human plasma: Development, validation and application of a UHPLC-MS/MS method
    Cambien, Guillaume
    Venisse, Nicolas
    Migeot, Virginie
    Rabouan, Sylvie
    Belmouaz, Mohamed
    Binson, Guillaume
    Albouy-Llaty, Marion
    Ayraud-Thevenot, Sarah
    Dupuis, Antoine
    CHEMOSPHERE, 2020, 242
  • [45] Distribution, bioaccumulation and human exposure risk of bisphenol analogues, bisphenol A diglycidyl ether and its derivatives in the Dongjiang River basin, south China
    Yang, Danlin
    Zhao, Daoming
    Chen, Honglin
    Cai, Yanpeng
    Liu, Yuxian
    Guo, Fen
    Li, Feilong
    Zhang, Yuan
    Xu, Zhihao
    Xue, Jingchuan
    Kannan, Kurunthachalam
    SCIENCE OF THE TOTAL ENVIRONMENT, 2024, 952
  • [46] Bisphenol a modification and how its structure influences human serum albumin binding force
    Hu, Xin
    Wang, Jian-Zhen
    Liu, Qi-Hang
    Ding, Xin
    Yin, Miao-Miao
    Hu, Yan-Jun
    JOURNAL OF MOLECULAR LIQUIDS, 2024, 401
  • [47] UHPLC-MS/MS method for the determination of bisphenol A and its chlorinated derivatives, bisphenol S, parabens, and benzophenones in human urine samples
    Vela-Soria, F.
    Ballesteros, O.
    Zafra-Gomez, A.
    Ballesteros, L.
    Navalon, A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (15) : 3773 - 3785
  • [48] Bisphenol A and its methylated congeners inhibit growth and interfere with microtubules in human fibroblasts in vitro
    Lehmann, L
    Metzler, M
    CHEMICO-BIOLOGICAL INTERACTIONS, 2004, 147 (03) : 273 - 285
  • [49] Trace analysis of bisphenol A and its analogues in eggs by ultra-performance liquid chromatography-tandem mass spectrometry
    Xiao, Zhiming
    Wang, Ruiguo
    Suo, Decheng
    Li, Tong
    Su, Xiaoou
    FOOD CHEMISTRY, 2020, 327
  • [50] Depot-Specific Analysis of Human Adipose Cells and Their Responses to Bisphenol S
    Peshdary, Vian
    Styles, George
    Gagne, Remi
    Yauk, Carole L.
    Sorisky, Alexander
    Atlas, Ella
    ENDOCRINOLOGY, 2020, 161 (06)