摘要
Ammonia detection is needed in several sectors including environmental monitoring, automobile industry, and in medical diagnosis. Conducting polymers, such as polyaniline (PANI), have been utilized to develop NH3 sensors operating at room temperature. However, the performance of these sensors in terms of sensitivity and selectivity need improvement. Functionalization of conducting PANI with metal nanocomposites have shown improved sensor performance. In this work, we report a highly sensitive copper-based nanocomposite for NH3 detection. The novelty lies in utilization of copper-ethylenediamine (Cu-en) nanocomposite functionalized over PANI for gas sensing. Resistance of the 20 wt% Cu-en with PANI increased 3.8 times upon exposure to 100 ppm of NH3. The nanocomposite sensor detected NH3 concentrations as low as 2 ppm. Further, the sensing mechanism was studied by in-situ IV characteristics and impedance spectroscopy during NH3 exposure. NH3 showed ionic interaction with PANI, and Cu2+. The strong affinity of Cu2+ for the lone pair of NH3 enhanced the sensor response from 0.78 to 3.8 for 100 ppm of NH3 at 20 degrees C. The sensor response was completely recovered after heating at 75 degrees C, which indicates reusability of the sensor. The sensor showed selectivity for NH3 over ethanol and H2S. The response was reasonably stable after bending the flexible sensor for 1000 times at a radius of 5 mm.
引用
收藏
页数:9
相关论文
共 66 条
[1]   A novel selective H2S sensor using dodecylamine and ethylenediamine functionalized graphene oxide [J].
Alaie, M. Malek ;
Jahangiri, M. ;
Rashidi, A. M. ;
Asl, A. Haghighi ;
Izadi, N. .
JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2015, 29 :97-103
[2]  
AQRA FMAM, 1995, TRANSIT METAL CHEM, V20, P123
[3]   MOFs for the Sensitive Detection of Ammonia: Deployment of fcuMOF Thin Films as Effective Chemical Capacitive Sensors [J].
Assen, Ayalew H. ;
Yassine, Omar ;
Shekhah, Osama ;
Eddaoudi, Mohamed ;
Salama, Khaled N. .
ACS SENSORS, 2017, 2 (09) :1294-1301
[4]  
Babu S.V. Veluru Jagadeesh., 2013, MAT SCI APPL, V4, P1, DOI DOI 10.4236/MSA.2013.41001
[5]   Review-Recent Advances in Electrochemical Impedance Spectroscopy Based Toxic Gas Sensors Using Semiconducting Metal Oxides [J].
Balasubramani, V ;
Chandraleka, S. ;
Rao, T. Subba ;
Sasikumar, R. ;
Kuppusamy, M. R. ;
Sridhar, T. M. .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (03)
[6]  
BALDWIN ME, 1962, SPECTROCHIM ACTA, V18, P1455
[7]   Enhanced photocatalytic activity of ethylenediamine-assisted tin oxide (SnO2) nanorods for methylene blue dye degradation [J].
Bhuvaneswari, K. ;
Nguyen, Ba-Son ;
Nguyen, Van-Huy ;
Nguyen, Vu-Quynh ;
Nguyen, Quang-Hung ;
Palanisamy, G. ;
Sivashanmugan, Kundan ;
Pazhanivel, T. .
MATERIALS LETTERS, 2020, 276
[8]   Interaction of Copper Phthalocyanine with Nitrogen Dioxide and Ammonia Investigation Using X-ray Absorption Spectroscopy and Chemiresistive Gas Measurements [J].
Chia, Liping Sharon ;
Du, Yong Hua ;
Palale, Suresh ;
Lee, Pooi See .
ACS OMEGA, 2019, 4 (06) :10388-10395
[9]  
Dellis J.-L., 2021, MATHWORKS FILE EXCHA
[10]  
Egenhofer C, 2014, The composition and drivers of energy prices and costs in energy-intensive industries: the case of ceramics, glass and chemicals