INTERCOMPARISON EXERCISE ON FUEL SAMPLES FOR DETERMINATION OF BIOCONTENT RATIO BY 14C ACCELERATOR MASS SPECTROMETRY

被引:3
|
作者
Varga, Tamas [1 ,2 ,3 ]
Hajdas, Irka [4 ]
Calcagnile, Lucio [5 ,6 ]
Quarta, Gianluca [5 ,6 ]
Major, Istvan [1 ,3 ]
Jull, A. J. Timothy [1 ,7 ,8 ]
Molnar, Anita [2 ,3 ]
Molnar, Mihaly [1 ]
机构
[1] Inst Nucl Res, Int Radiocarbon AMS Competence & Training INTERAC, H-4026 Debrecen, Hungary
[2] Univ Debrecen, Doctoral Sch Phys, Egyet Ter 1, H-4032 Debrecen, Hungary
[3] Isotoptech Ltd, H-4026 Debrecen, Hungary
[4] ETHZ, Lab Ion Beam Phys, CH-8093 Zurich, Switzerland
[5] Univ Salento, CEDAD Ctr Appl Phys Dating & Diagnost, Dept Math & Phys Ennio de Giorgi, Lecce, Italy
[6] INFN Natl Inst Nucl Phys, Lecce, Italy
[7] Univ Arizona, Dept Geosci, Tucson, AZ 85721 USA
[8] Univ Arizona, AMS Lab, Tucson, AZ 85721 USA
关键词
AMS; biobased carbon content; liquid fuel; radiocarbon; BIOBASED CARBON CONTENT; BIOGENIC FRACTION; AMS; PRECISION; ACCURACY; INTEGRATION; MICADAS; DIESEL;
D O I
10.1017/RDC.2023.7
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
The method of determining the biobased carbon content in liquid fuel samples is standardized, but different laboratories use different protocols during sample preparation and perform the measurements using different machines. The accelerator mass spectrometry (AMS) laboratories use different combustion, preparation, and graphitization methods for the graphite production for the spectrometric measurements. As a result, the intercomparison between the laboratories is inevitable to prove precision and accuracy and to demonstrate that the results are comparable. In this study, we present the results of an intercomparison campaign involving three C-14 accelerator mass spectrometry laboratories. Five samples were used in the measurement campaign, including two biocomponents (fatty acid methyl ester, hydrotreated vegetable oil), one fossil component (fossil diesel), and two blends (mixtures of fossil and biocomponent with 90-10% mixing ratio) in the laboratories of CEDAD (Italy), ETH (Switzerland), and INTERACT (Hungary). The results presented by the laboratories are comparable, and all three laboratories could determine the biobased carbon content of the samples within 1% relative uncertainty, which is acceptable in the scientific, economic, and industrial fields for biocomponent determination.
引用
收藏
页码:539 / 548
页数:10
相关论文
共 42 条
  • [1] Feasibility studies of RFQ based 14C accelerator mass spectrometry
    Guo, Zhiyu
    Liu, Kexin
    Yan, Xueqing
    Xie, Yi
    Fang, Jiaxun
    Chen, Jiaer
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 259 (01) : 204 - 207
  • [2] Low-level 14C measurements and Accelerator Mass Spectrometry
    Litherland, AE
    Gove, HE
    Beukens, RP
    Zhao, XL
    Kieser, WE
    TOPICAL WORKSHOP ON LOW RADIOACTIVITY TECHNIQUES, 2005, 785 : 48 - 56
  • [3] THE IAEA FORENSICS PROGRAM: RESULTS OF THE AMS 14C INTERCOMPARISON EXERCISE ON CONTEMPORARY WINES AND COFFEES
    Quarta, G.
    Hajdas, I
    Molnar, M.
    Varga, T.
    Calcagnile, L.
    D'Elia, M.
    Molnar, A.
    Dias, J. F.
    Jull, A. J. T.
    RADIOCARBON, 2022, 64 (06) : 1513 - 1524
  • [4] 14C Ages and Calendar Years of Japanese Nails Measured with Accelerator Mass Spectrometry
    Nagata, Kazuhiro
    Furunushi, Yasuko
    Matsubara, Akihiro
    Saito-Kokubu, Yoko
    Nakamura, Toshio
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 2019, 105 (04): : 488 - 491
  • [5] 14C Ages and Calendar Years of Japanese Swords Measured with Accelerator Mass Spectrometry
    Nagata, Kazuhiro
    Matsubara, Akihiro
    Saito-Kokubu, Yoko
    Nakamura, Toshio
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 2016, 102 (12): : 736 - 741
  • [6] Evaluation of 14 C/ 12 C ratio measurements using accelerator mass spectrometry with standard materials under different graphitization conditions
    Park, Sae-Hoon
    Lee, Seung-Won
    Kim, Yu-Seok
    APPLIED RADIATION AND ISOTOPES, 2025, 215
  • [7] Biological and biomedical 14C-accelerator mass spectrometry and graphitization of carbonaceous samples
    Chung, Ill-Min
    Kim, Seung-Hyun
    ANALYST, 2013, 138 (12) : 3347 - 3355
  • [8] Rapid radiocarbon (14C) analysis of coral and carbonate samples using a continuous-flow accelerator mass spectrometry (CFAMS) system
    McIntyre, Cameron P.
    Roberts, Mark L.
    Burton, Joshua R.
    McNichol, Ann P.
    Burke, Andrea
    Robinson, Laura F.
    von Reden, Karl F.
    Jenkins, William J.
    PALEOCEANOGRAPHY, 2011, 26
  • [9] Simultaneous AMS determination of 14C content and total carbon mass in biological samples
    Zoppi, U.
    Arjomand, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2010, 268 (7-8) : 1307 - 1308
  • [10] Study on Experimental Conditions of Compact 14C Accelerator Mass Spectrometer
    Zhao Z.-C.
    Qin Y.-F.
    Li J.-H.
    Lu H.-J.
    Chen L.-S.
    Lan H.-H.
    Li Q.
    Xie Y.-C.
    Li Z.-M.
    Liu M.-J.
    Wei S.-Y.
    Qi M.-L.
    Bao Y.-W.
    He M.
    Jiang S.
    Shen H.-T.
    Journal of Chinese Mass Spectrometry Society, 2020, 41 (05): : 462 - 469