Swept-source optical coherence tomography angiography automatic analysis of microvascular changes secondary to systemic hypertension

被引:7
|
作者
Sargues, Lidia Remoli [1 ,2 ]
Adsuara, Clara Monferrer [1 ]
Navarro, Veronica Castro [1 ]
Palop, Catalina Navarro [1 ]
Hernandez, Javier Montero [1 ]
Taulet, Enrique Cervera [1 ]
机构
[1] Consorcio Hosp Gen Univ Valencia, Dept Ophthalmol, Valencia, Spain
[2] Hosp Gen Univ Valencia, Serv Oftalmol, Ave Tres Cruces 2, Valencia 46014, Spain
关键词
Anatomy; biochemistry; physiology; retinal pathology; research; techniques of retinal examination; preventive medicine; screening; practice management;
D O I
10.1177/11206721221146674
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Introduction The aim of our study is to report swept-source optical coherence tomography angiography (SS-OCTA) quantitative parameters of retinal and choroidal microvasculature in patients with systemic hypertension (HTN) using a built-in software of SS-OCTA. Methods We performed a retrospective study. This study enrolled 93 eyes of 51 subjects with HTN and 71 eyes of 38 healthy subjects. OCTA quantitative parameters (vessel density (VD) and foveal avascular zone (FAZ) area of superficial capillary plexus (SCP), middle capillary plexus (MCP), deep capillary plexus (DCP), total capillary plexus (TCP) and choriocapillaris (CC)) of the OCTA cube of 4,5 mm x 4,5 mm were recorded. Results A decrease of parafoveal VD in CC, DCP and TCP were demonstrated between HTN group and control group (p < 0,05). Conversely, no differences were demonstrated in parafoveal VD of SCP and MCP (p > 0,05). Subgroup analysis revealed a diminution of central VD at SCP, DCP and TCP in patients taking one antihypertensive drug compared to patients treated with two medications (p < 0,05). Correlation analysis showed a significant, albeit weak, negative correlation between HTN duration, and parafoveal VD in the SCP and FAZ area at SCP, DCP and TCP (p < 0,05 and r < 0,300). Conclusion When normative data are available, OCTA might be used as a potential tool in the prevention and follow-up of end-organ damage secondary to HTN. Nonetheless, further studies are needed to confirm this hypothesis.
引用
收藏
页码:1452 / 1458
页数:7
相关论文
共 16 条
  • [1] Optical coherence tomography angiography quantitative analysis of retinal and choroidal microvasculature in patients with dyslipidemia
    Remoli Sargues, Lidia
    Monferrer Adsuara, Clara
    Castro Navarro, Veronica
    Navarro Palop, Catalina
    Montero Hernandez, Javier
    Cervera Taulet, Enrique
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (04) : 1666 - 1671
  • [2] New insights in pathogenic mechanism of hydroxychloroquine retinal toxicity through optical coherence tomography angiography analysis
    Remoli Sargues, Lidia
    Monferrer Adsuara, Clara
    Castro Navarro, Veronica
    Hernandez Garfella, Maria Luisa
    Hernandez Bel, Laura
    Navarro Palop, Catalina
    Montero Hernandez, Javier
    Cervera Taulet, Enrique
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (06) : 3599 - 3608
  • [3] Optical coherence tomography angiography analysis of aneurismal type 1 neovascularization in a cohort of white patients
    Montero Hernandez, Javier
    Remoli Sargues, Lidia
    Monferrer Adsuara, Clara
    Castro Navarro, Veronica
    Navarro Palop, Catalina
    Cervera Taulet, Enrique
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (04) : 2338 - 2346
  • [4] Changes in optical coherence tomography angiography in patients with vitamin D deficiency
    Icel, Erel
    Ucak, Turgay
    Ugurlu, Adem
    Erdol, Hidayet
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (06) : 3514 - 3521
  • [5] Feasibility of microscope-integrated swept-source optical coherence tomography in canaloplasty
    Xu, Huan
    Fang, Wangyi
    Liu, Guangxing
    Fan, Jinyu
    Yu, Jian
    Zong, Yuan
    Jiang, Chunhui
    Shi, Guohua
    Sun, Xinghuai
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (23)
  • [6] Optical coherence tomography angiography analysis in patients with intracranial hypertension
    Remoli-Sargues, Lidia
    Monferrer-Adsuara, Clara
    Lopez-Salvador, Belen
    Garcia-Villanueva, Carolina
    Gracia-Garcia, Alicia
    Castro-Navarro, Veronica
    Cervera-Taulet, Enrique
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2024, 34 (05) : 1586 - 1593
  • [7] Three-dimensional segmentation and depth-encoded visualization of choroidal vasculature using swept-source optical coherence tomography
    Zhou, Hao
    Bacci, Tommaso
    Freund, K. Bailey
    Wang, Ruikang K.
    EXPERIMENTAL BIOLOGY AND MEDICINE, 2021, 246 (20) : 2238 - 2245
  • [8] Postexercise Recovery of Schlemm's Canal and Intraocular Pressure in Healthy Individuals: An Observational Study Using Swept-Source Optical Coherence Tomography
    Li, Mu
    Yan, Xiaoqin
    Luo, Zhaoxia
    Zhang, Hong
    JOURNAL OF OPHTHALMOLOGY, 2018, 2018
  • [9] Peripheral lamina cribrosa depth in primary open-angle glaucoma: a swept-source optical coherence tomography study of lamina cribrosa
    Kim, Y. W.
    Kim, D. W.
    Jeoung, J. W.
    Kim, D. M.
    Park, K. H.
    EYE, 2015, 29 (10) : 1368 - 1374
  • [10] Swept Source Optical Coherence Tomography Assessment of Bursa Premacularis in Healthy Eyes
    Carpineto, Paolo
    D'Aloisio, Rossella
    Guarini, Daniele
    Iafigliola, Carla
    Cerino, Luca
    Sciarroni, Elisabetta
    Di Antonio, Luca
    Clemente, Katia
    Di Nicola, Marta
    Di Martino, Giuseppe
    Mastropasqua, Rodolfo
    Toto, Lisa
    BIOMED RESEARCH INTERNATIONAL, 2020, 2020