ITERATIVE RECONSTRUCTION; MULTIDETECTOR CT; BODY-WEIGHT; ENHANCEMENT; DIAGNOSIS; QUANTIFICATION; AGREEMENT; ACCURACY; LIVER;
D O I
10.1038/s41598-023-50238-6
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study aimed to establish quantitative references of the normal bowel wall iodine concentration (BWIC) using dual energy CT (DECT). This single-center retrospective study included 248 patients with no history of gastrointestinal disease who underwent abdominal contrast-enhanced DECT between January and April 2022. The BWIC was normalized by the iodine concentration of upper abdominal organs (BWICorgan,) and the iodine concentration (IC) of the aorta (BWICaorta). BWIC decreased from the stomach to the rectum (mean 2.16 +/- 0.63 vs. 2.19 +/- 0.63 vs. 2.1 +/- 0.58 vs. 1.67 +/- 0.47 vs. 1.31 +/- 0.4 vs. 1.18 +/- 0.34 vs. 0.94 +/- 0.26 mgI/mL for the stomach, duodenum, jejunum, ileum, right colon, left colon and rectum, respectively; P < 0.001). By multivariate analysis, BWIC was associated with a higher BMI (OR:1.01, 95% CI 1.00-1.02, P < 0.001) and with a higher injected contrast dose (OR: 1.51; 95% CI 1.36-1.66, P < 0.001 and 2.06; 95% CI 1.88-2.26, P < 0.001 for 500 mgI/kg and 600 mgI/kg doses taking 400 mgI/kg dose as reference). The BWICorgan was shown independent from patients and contrast- related variables while the BWICaorta was not. BWIC varies according to bowel segments and is dependent on the total iodine dose injected. It shall be normalized with the IC of the upper abdominal organs.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Multivendor Comparison of Quantification Accuracy of Iodine Concentration and Attenuation Measurements by Dual-Energy CT: A Phantom Study
    Chen, Yong
    Zhong, Jingyu
    Wang, Lan
    Shi, Xiaomeng
    Chang, Rui
    Fan, Jing
    Jiang, Jiang
    Xia, Yihan
    Yan, Fuhua
    Yao, Weiwu
    Zhang, Huan
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 219 (05) : 827 - 839
  • [42] Optimizing dual-energy CT technique for iodine-based contrast-to-noise ratio, a theoretical study
    Terzioglu, Fatma
    Sidky, Emil Y.
    Phillips, John Paul
    Reiser, Ingrid S.
    Bal, Guillaume
    Pan, Xiaochuan
    MEDICAL PHYSICS, 2024, 51 (04) : 2871 - 2881
  • [43] Detection of fatty liver using virtual non-contrast dual-energy CT
    Zhang, Pengcheng Peter
    Choi, Hailey H.
    Ohliger, Michael A.
    ABDOMINAL RADIOLOGY, 2022, 47 (06) : 2046 - 2056
  • [44] Detection of fatty liver using virtual non-contrast dual-energy CT
    Pengcheng Peter Zhang
    Hailey H. Choi
    Michael A. Ohliger
    Abdominal Radiology, 2022, 47 : 2046 - 2056
  • [45] Dual-Energy CT Iodine Mapping and 40-keV Monoenergetic Applications in the Diagnosis of Acute Bowel Ischemia
    Lourenco, Pedro D. M.
    Rawski, Ryan
    Mohammed, Mohammed F.
    Khosa, Faisal
    Nicolaou, Savvas
    McLaughlin, Patrick
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 211 (03) : 564 - 570
  • [46] Quantitative myocardial perfusion with stress dual-energy CT: iodine concentration differences between normal and ischemic or necrotic myocardium. Initial experience
    Delgado Sanchez-Gracian, Carlos
    Oca Pernas, Roque
    Trinidad Lopez, Carmen
    Santos Armentia, Eloisa
    Vaamonde Liste, Antonio
    Vazquez Caamano, Maria
    Tardaguila de la Fuente, Gonzalo
    EUROPEAN RADIOLOGY, 2016, 26 (09) : 3199 - 3207
  • [47] Quantitative myocardial perfusion with stress dual-energy CT: iodine concentration differences between normal and ischemic or necrotic myocardium. Initial experience
    Carlos Delgado Sánchez-Gracián
    Roque Oca Pernas
    Carmen Trinidad López
    Eloísa Santos Armentia
    Antonio Vaamonde Liste
    María Vázquez Caamaño
    Gonzalo Tardáguila de la Fuente
    European Radiology, 2016, 26 : 3199 - 3207
  • [48] Dual-energy CT of acute bowel ischemia-influence on diagnostic accuracy and reader confidence
    Oberparleiter, Moritz
    Vosshenrich, Jan
    Breit, Hanns-Christian
    Kaiser, Philippe
    Hehenkamp, Paul
    Harder, Dorothee
    Boll, Daniel T.
    Zech, Christoph J.
    Obmann, Markus M.
    EUROPEAN RADIOLOGY, 2025, 35 (03) : 1405 - 1414
  • [49] Effects of Patient Size and Radiation Dose on Iodine Quanti fi cation in Dual-Source Dual-Energy CT
    Jiang, Xia
    Yang, Xiangyu
    Hintenlang, David E.
    White, Richard D.
    ACADEMIC RADIOLOGY, 2021, 28 (01) : 96 - 105
  • [50] Dual-energy micro-CT for quantifying the time-course and staining characteristics of ex-vivo animal organs treated with iodine- and gadolinium-based contrast agents
    Juliana Martins de Souza e Silva
    Julian Utsch
    Melanie A. Kimm
    Sebastian Allner
    Michael F. Epple
    Klaus Achterhold
    Franz Pfeiffer
    Scientific Reports, 7