Quantifying iodine concentration in the normal bowel wall using dual-energy CT: influence of patient and contrast characteristics

被引:4
|
作者
Nehnahi, Majida [1 ]
Simon, Gabriel [1 ]
Moinet, Romain [1 ]
Piton, Gael [2 ]
Camelin, Camille [1 ]
Ronot, Maxime [3 ]
Delabrousse, Eric [1 ,4 ]
Calame, Paul [1 ,4 ]
机构
[1] Univ Bourgogne Franche Comte, Dept Radiol, CHU Besancon, F-25030 Besancon, France
[2] Univ Bourgogne Franche Comte, Med Intens Care Unit, CHU Besancon, F-25030 Besancon, France
[3] Univ Hosp Paris Nord Val de Seine, AP HP, Dept Radiol, F-92110 Beaujon, Clichy, France
[4] Univ Franche Comte, EA Nanomed Lab 4662, Imagery & Therapeut, Besancon, France
关键词
ITERATIVE RECONSTRUCTION; MULTIDETECTOR CT; BODY-WEIGHT; ENHANCEMENT; DIAGNOSIS; QUANTIFICATION; AGREEMENT; ACCURACY; LIVER;
D O I
10.1038/s41598-023-50238-6
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study aimed to establish quantitative references of the normal bowel wall iodine concentration (BWIC) using dual energy CT (DECT). This single-center retrospective study included 248 patients with no history of gastrointestinal disease who underwent abdominal contrast-enhanced DECT between January and April 2022. The BWIC was normalized by the iodine concentration of upper abdominal organs (BWICorgan,) and the iodine concentration (IC) of the aorta (BWICaorta). BWIC decreased from the stomach to the rectum (mean 2.16 +/- 0.63 vs. 2.19 +/- 0.63 vs. 2.1 +/- 0.58 vs. 1.67 +/- 0.47 vs. 1.31 +/- 0.4 vs. 1.18 +/- 0.34 vs. 0.94 +/- 0.26 mgI/mL for the stomach, duodenum, jejunum, ileum, right colon, left colon and rectum, respectively; P < 0.001). By multivariate analysis, BWIC was associated with a higher BMI (OR:1.01, 95% CI 1.00-1.02, P < 0.001) and with a higher injected contrast dose (OR: 1.51; 95% CI 1.36-1.66, P < 0.001 and 2.06; 95% CI 1.88-2.26, P < 0.001 for 500 mgI/kg and 600 mgI/kg doses taking 400 mgI/kg dose as reference). The BWICorgan was shown independent from patients and contrast- related variables while the BWICaorta was not. BWIC varies according to bowel segments and is dependent on the total iodine dose injected. It shall be normalized with the IC of the upper abdominal organs.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Dual-contrast decomposition of dual-energy CT using convolutional neural networks
    Shapira, Nadav
    Cao, Wenchao
    Liu, Leening P.
    Leiner, Tim
    Smits, Maarten L. J.
    Noel, Peter B.
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [22] Gastrointestinal Applications of Iodine Quantification Using Dual-Energy CT: A Systematic Review
    Xu, Jack Junchi
    Taudorf, Mikkel
    Ulriksen, Peter Sommer
    Achiam, Michael Patrick
    Resch, Timothy Andrew
    Nielsen, Michael Bachmann
    Lonn, Lars Birger
    Hansen, Kristoffer Lindskov
    DIAGNOSTICS, 2020, 10 (10)
  • [23] Iodine density mapping for the diagnosis of acute bowel ischemia using fast kV-switching dual-energy CT
    Xu, Jack Junchi
    Ulriksen, Peter Sommer
    Jawad, Samir
    Rohde, Yecatarina Zincuk
    Sejer, Morten
    Achiam, Michael Patrick
    Resch, Timothy Andrew
    Lonn, Lars
    Hansen, Kristoffer Lindskov
    ABDOMINAL RADIOLOGY, 2024, 49 (01) : 312 - 319
  • [24] Influence of contrast medium on tophus detection using dual-energy CT: phantom study and clinical illustration
    Kotlyarov, Maximilian
    Mews, Jurgen
    Ulas, Sevtap Tugce
    Ziegeler, Katharina
    Hamm, Bernd
    Diekhoff, Torsten
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2023, 7 (01)
  • [25] Iodine density mapping for the diagnosis of acute bowel ischemia using fast kV-switching dual-energy CT
    Jack Junchi Xu
    Peter Sommer Ulriksen
    Samir Jawad
    Yecatarina Zincuk Rohde
    Morten Sejer
    Michael Patrick Achiam
    Timothy Andrew Resch
    Lars Lönn
    Kristoffer Lindskov Hansen
    Abdominal Radiology, 2024, 49 : 312 - 319
  • [26] Influence of contrast medium on tophus detection using dual-energy CT: phantom study and clinical illustration
    Maximilian Kotlyarov
    Jürgen Mews
    Sevtap Tugce Ulas
    Katharina Ziegeler
    Bernd Hamm
    Torsten Diekhoff
    European Radiology Experimental, 7
  • [27] Postablation assessment of hepatocellular carcinoma using dual-energy CT: Comparison of half versus standard iodine contrast medium
    Lin, Yuan-Mao
    Chiou, Yi-You
    Wu, Mei-Han
    Huang, Shan Su
    Shen, Shu-Huei
    PLOS ONE, 2019, 14 (07):
  • [28] Ringlike Peripheral Increased Iodine Concentration for the Differentiation of Primary Lung Cancer and Pulmonary Metastases on Contrast-Enhanced Dual-Energy CT
    Sato, Yoshinao
    Ishiyama, Mitsutomi
    Nakano, Sachiko
    Nakao, Masayuki
    Mun, Mingyon
    Ninomiya, Hironori
    Terauchi, Takashi
    Oikado, Katsunori
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2023, 220 (06) : 828 - 836
  • [29] In vivo measurement of iron concentration using dual-source, dual-energy CT
    Weavers, Paul T.
    Jacobsen, Megan
    Liu, Xin
    Morin, Richard L.
    McCollough, Cynthia H.
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [30] Accuracy of dual-energy computed tomography for the measurement of iodine concentration using cardiac CT protocols: validation in a phantom model
    James D. Koonce
    Rozemarijn Vliegenthart
    U. Joseph Schoepf
    Bernhard Schmidt
    Amy E. Wahlquist
    Paul J. Nietert
    Gorka Bastarrika
    Thomas G. Flohr
    Felix G. Meinel
    European Radiology, 2014, 24 : 512 - 518