Quantifying iodine concentration in the normal bowel wall using dual-energy CT: influence of patient and contrast characteristics

被引:4
|
作者
Nehnahi, Majida [1 ]
Simon, Gabriel [1 ]
Moinet, Romain [1 ]
Piton, Gael [2 ]
Camelin, Camille [1 ]
Ronot, Maxime [3 ]
Delabrousse, Eric [1 ,4 ]
Calame, Paul [1 ,4 ]
机构
[1] Univ Bourgogne Franche Comte, Dept Radiol, CHU Besancon, F-25030 Besancon, France
[2] Univ Bourgogne Franche Comte, Med Intens Care Unit, CHU Besancon, F-25030 Besancon, France
[3] Univ Hosp Paris Nord Val de Seine, AP HP, Dept Radiol, F-92110 Beaujon, Clichy, France
[4] Univ Franche Comte, EA Nanomed Lab 4662, Imagery & Therapeut, Besancon, France
关键词
ITERATIVE RECONSTRUCTION; MULTIDETECTOR CT; BODY-WEIGHT; ENHANCEMENT; DIAGNOSIS; QUANTIFICATION; AGREEMENT; ACCURACY; LIVER;
D O I
10.1038/s41598-023-50238-6
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study aimed to establish quantitative references of the normal bowel wall iodine concentration (BWIC) using dual energy CT (DECT). This single-center retrospective study included 248 patients with no history of gastrointestinal disease who underwent abdominal contrast-enhanced DECT between January and April 2022. The BWIC was normalized by the iodine concentration of upper abdominal organs (BWICorgan,) and the iodine concentration (IC) of the aorta (BWICaorta). BWIC decreased from the stomach to the rectum (mean 2.16 +/- 0.63 vs. 2.19 +/- 0.63 vs. 2.1 +/- 0.58 vs. 1.67 +/- 0.47 vs. 1.31 +/- 0.4 vs. 1.18 +/- 0.34 vs. 0.94 +/- 0.26 mgI/mL for the stomach, duodenum, jejunum, ileum, right colon, left colon and rectum, respectively; P < 0.001). By multivariate analysis, BWIC was associated with a higher BMI (OR:1.01, 95% CI 1.00-1.02, P < 0.001) and with a higher injected contrast dose (OR: 1.51; 95% CI 1.36-1.66, P < 0.001 and 2.06; 95% CI 1.88-2.26, P < 0.001 for 500 mgI/kg and 600 mgI/kg doses taking 400 mgI/kg dose as reference). The BWICorgan was shown independent from patients and contrast- related variables while the BWICaorta was not. BWIC varies according to bowel segments and is dependent on the total iodine dose injected. It shall be normalized with the IC of the upper abdominal organs.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Quantifying iodine concentration in the normal bowel wall using dual-energy CT: influence of patient and contrast characteristics
    Majida Nehnahi
    Gabriel Simon
    Romain Moinet
    Gael Piton
    Camille Camelin
    Maxime Ronot
    Éric Delabrousse
    Paul Calame
    Scientific Reports, 13
  • [2] Quantifying iodine concentration in the normal bowel wall using dual-energy CT: influence of patient and contrast characteristics (vol 13, 22714, 2023)
    Nehnahi, Majida
    Simon, Gabriel
    Moinet, Romain
    Piton, Gael
    Camelin, Camille
    Ronot, Maxime
    Delabrousse, Eric
    Calame, Paul
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [3] Bowel Peristalsis Artifact on Dual-Energy CT: In Vitro Study on the Influence of Different Dual-Energy CT Platforms and Enteric Contrast Agents
    Obmann, Markus M.
    Sun, Yuxin
    An, Chansik
    Ohliger, Michael A.
    Wang, Zhen J.
    Yeh, Benjamin M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 218 (02) : 290 - 299
  • [4] Use of Dual-Energy CT and Iodine Maps in Evaluation of Bowel Disease
    Fulwadhva, Urvi P.
    Wortman, Jeremy R.
    Sodickson, Aaron D.
    RADIOGRAPHICS, 2016, 36 (02) : 393 - 406
  • [5] Quantification of iodine concentration by dual-energy CT in patients with acute pancreatitis
    Utrera Perez, E.
    Tardaguila de la Fuente, G.
    Martinez Rodriguez, C.
    Villanueva Campos, A.
    Jurado Basildo, C.
    Garcia Pouton, N.
    RADIOLOGIA, 2020, 62 (05): : 360 - 364
  • [6] Contrast thresholds for detection of various iodine concentrations in subtraction CT and dual-energy CT systems
    Heshmat, Anahita
    Barreto, Izabella
    Rill, Lynn
    Liu, Sitong
    Patel, Romin
    Arreola, Manuel
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (01):
  • [7] Iodine Images in Dual-energy CT: Detection of Hepatic Steatosis by Quantitative Iodine Concentration Values
    Beck, Stefanie
    Jahn, Laurenz
    Deniffel, Dominik
    Riederer, Isabelle
    Sauter, Andreas
    Makowski, Marcus R.
    Pfeiffer, Daniela
    JOURNAL OF DIGITAL IMAGING, 2022, 35 (06) : 1738 - 1747
  • [8] Iodine Images in Dual-energy CT: Detection of Hepatic Steatosis by Quantitative Iodine Concentration Values
    Stefanie Beck
    Laurenz Jahn
    Dominik Deniffel
    Isabelle Riederer
    Andreas Sauter
    Marcus R. Makowski
    Daniela Pfeiffer
    Journal of Digital Imaging, 2022, 35 : 1738 - 1747
  • [9] Tumor hypoxia assessment using dual-energy CT derived iodine concentration in head and neck cancer
    Edmund, Jens
    Maare, Christian
    Mortensen, Henriette Klitgaard
    Skougaard, Kristin
    Lonkvist, Camilla Kjaer
    Rechner, Laura Ann
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3842 - S3845
  • [10] In vivo comparison of tantalum, tungsten, and bismuth enteric contrast agents to complement intravenous iodine for double-contrast dual-energy CT of the bowel
    Rathnayake, Samira
    Mongan, John
    Torres, Andrew S.
    Colborn, Robert
    Gao, Dong-Wei
    Yeh, Benjamin M.
    Fu, Yanjun
    CONTRAST MEDIA & MOLECULAR IMAGING, 2016, 11 (04) : 254 - 261