Evaluating Direct Shear Performance of Steel Fiber-Reinforced Concrete

被引:3
作者
Carrillo, Julian [1 ,2 ]
Salcedo, Eyli [1 ]
Rojas, Fabian [3 ]
机构
[1] Univ Mil Nueva Granada, Dept Civil Engn, Bogota 110111, Colombia
[2] Colombian Earthquake Engn Res CEER Network, Bogota 110111, Colombia
[3] Univ Chile, Dept Civil Engn, Santiago 8370449, Chile
关键词
Direct shear; Steel fibers; Hooked-end fibers; Residual performance; Toughness; STRENGTH; BEHAVIOR;
D O I
10.1061/JMCEE7.MTENG-16532
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Shear stress is one of the main design parameters for structures subjected to seismic demands. Steel fibers are a viable option for the shear reinforcement of concrete elements because they tend to increase the tensile strength and post-cracking performance of concrete. This study evaluated the direct shear strength of steel fiber-reinforced concrete (SFRC) using standardized specimens. The experimental program included direct shear tests of 14 column- and beam-type specimens using three test methods: FIP, JSCE-SF6, and Z-type. The steel fibers had double hooks at the ends and an aspect ratio of 65. The nominal fiber dosages (FD) were 30 and 60 kg/m3, which correspond to fiber contents of 0.38% and 0.76%, respectively. The analysis of 887 data points measured during direct shear tests of the 14 specimens from this study and 69 specimens reported in the literature was performed by analyzing the trends of the shear strength parameters at the first cracking, maximum strength, and residual shear as a function of the reinforcement index. The measured results showed that the shear strength of SFRC at the limit states of cracking, maximum, and residual with FD of 60 kg/m3 was between 3% and 52%, 5% and 50%, and 29% and 63%, respectively, greater than the values associated with FD of 30 kg/m3. The study also proposed models to estimate the toughness, and the maximum and the residual shear strengths associated with specific displacements.
引用
收藏
页数:10
相关论文
共 33 条
[1]  
ACI (American Concrete Institute), 2009, State-of-the-art report on fiber reinforced concrete
[2]  
Alvarez R., 2015, Evaluation of the energy dissipation capacity of slab-column systems made of steel fiber reinforced concrete
[3]  
[Anonymous], 2019, 31819 ACI
[4]  
[Anonymous], 2016, STANDARD TEST METHOD, P1, DOI [10.1520/E0384-22, DOI 10.1520/E0384-22]
[5]   Shear strength of steel fiber-reinforced concrete beams [J].
Araujo, Daniel de Lima ;
Tiburcio Nunes, Fernanda Gabrielle ;
Toledo Filho, Romildo Dias ;
Souza de Andrade, Moacir Alexandre .
ACTA SCIENTIARUM-TECHNOLOGY, 2014, 36 (03) :389-397
[6]  
Barragán B, 2006, ACI MATER J, V103, P251
[7]   Influence of yield stress and compressive strength on direct shear behaviour of steel fibre-reinforced concrete [J].
Boulekbache, Bensaid ;
Hamrat, Mostefa ;
Chemrouk, Mohamed ;
Amziane, Sofiane .
CONSTRUCTION AND BUILDING MATERIALS, 2012, 27 (01) :6-14
[8]   Correlation between results obtained from four-point bending tests (4PBT) and double punch tests (DPT) in concrete reinforced with hooked-end steel fibers [J].
Carrillo, Julian ;
Torres, Diego ;
Guerrero, Hector .
ENGINEERING STRUCTURES, 2021, 239
[9]   Model for estimating the flexural performance of concrete reinforced with hooked end steel fibers using three-point bending tests [J].
Carrillo, Julian ;
Vargas, Juan D. ;
Alcocer, Sergio M. .
STRUCTURAL CONCRETE, 2021, 22 (03) :1760-1783
[10]  
CEN (European Committee for Standardization), 2007, Testing sprayed concretePart 7: Fiber content of fiber reinforced concrete