Implantable bioelectronic systems for early detection of kidney transplant rejection

被引:64
作者
Madhvapathy, Surabhi R. [1 ,2 ]
Wang, Jiao-Jing [3 ]
Wang, Heling [4 ,5 ,6 ]
Patel, Manish [2 ,7 ]
Chang, Anthony [8 ]
Zheng, Xin [3 ]
Huang, Yonggang [4 ,5 ]
Zhang, Zheng J. [3 ,9 ,10 ]
Gallon, Lorenzo [3 ,11 ]
Rogers, John A. [1 ,2 ,12 ,13 ]
机构
[1] Northwestern Univ, Dept Mat Sci & Engn, Evanston, IL 60208 USA
[2] Northwestern Univ, Querrey Simpson Inst Bioelectron, Evanston, IL 60208 USA
[3] Northwestern Univ, Comprehens Transplant Ctr, Chicago, IL 60611 USA
[4] Northwestern Univ, Dept Mech Engn, Evanston, IL 60208 USA
[5] Northwestern Univ, Dept Civil Engn, Evanston, IL 60208 USA
[6] Tsinghua Univ, Lab Flexible Elect Technol, Beijing 100085, Peoples R China
[7] Univ Illinois, Dept Intervent Radiol, Chicago, IL 60612 USA
[8] Univ Chicago, Dept Pathol, Chicago, IL 60637 USA
[9] Northwestern Univ, Dept Surg, Feinberg Sch Med, Chicago, IL 60611 USA
[10] Northwestern Univ, Simpson Querrey Inst BioNanotechnol, Chicago, IL 60611 USA
[11] Northwestern Univ, Dept Nephrol, Chicago, IL 60611 USA
[12] Northwestern Univ, Dept Biomed Engn, Evanston, IL 60208 USA
[13] Northwestern Univ, Dept Neurol Surg, Chicago, IL 60611 USA
关键词
TEMPERATURE;
D O I
10.1126/science.adh7726
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Early-stage organ transplant rejection can be difficult to detect. Percutaneous biopsies occur infrequently and are risky, and measuring biomarker levels in blood can lead to false-negative and -positive outcomes. We developed an implantable bioelectronic system capable of continuous, real-time, long-term monitoring of the local temperature and thermal conductivity of a kidney for detecting inflammatory processes associated with graft rejection, as demonstrated in rat models. The system detects ultradian rhythms, disruption of the circadian cycle, and/or a rise in kidney temperature. These provide warning signs of acute kidney transplant rejection that precede changes in blood serum creatinine/urea nitrogen by 2 to 3 weeks and approximately 3 days for cases of discontinued and absent administration of immunosuppressive therapy, respectively.
引用
收藏
页码:1105 / 1112
页数:8
相关论文
共 33 条
[1]   Complications of Percutaneous Renal Biopsy [J].
Bakdash, Kenaz ;
Schramm, Kristofer M. ;
Annam, Aparna ;
Brown, Matthew ;
Kondo, Kimi ;
Lindquist, Jonathan D. .
SEMINARS IN INTERVENTIONAL RADIOLOGY, 2019, 36 (02) :97-103
[2]   Synergistic effects of malononitrilamides (FK778, FK779) with tacrolimus (FK506) in prevention of acute heart and kidney allograft rejection and reversal of ongoing heart allograft rejection in the rat [J].
Bilolo, KK ;
Ouyang, J ;
Wang, X ;
Zhu, SY ;
Jiang, WL ;
Qi, SJ ;
Xu, DS ;
Hebert, MJ ;
Bekersky, I ;
Fitzsimmons, WE ;
Chen, HF .
TRANSPLANTATION, 2003, 75 (11) :1881-1887
[3]   Cell-Free DNA and Active Rejection in Kidney Allografts [J].
Bloom, Roy D. ;
Bromberg, Jonathan S. ;
Poggio, Emilio D. ;
Bunnapradist, Suphamai ;
Langone, Anthony J. ;
Sood, Puneet ;
Matas, Arthur J. ;
Mehta, Shikha ;
Mannon, Roslyn B. ;
Sharfuddin, Asif ;
Fischbach, Bernard ;
Narayanan, Mohanram ;
Jordan, Stanley C. ;
Cohen, David ;
Weir, Matthew R. ;
Hiller, David ;
Prasad, Preethi ;
Woodward, Robert N. ;
Grskovic, Marica ;
Sninsky, John J. ;
Yee, James P. ;
Brennan, Daniel C. .
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2017, 28 (07) :2221-2232
[4]   Kidney transplantation: Mechanisms of rejection and acceptance [J].
Cornell, Lynn D. ;
Smith, R. Neal ;
Colvin, Robert B. .
ANNUAL REVIEW OF PATHOLOGY-MECHANISMS OF DISEASE, 2008, 3 :189-220
[5]   Advanced approaches for quantitative characterization of thermal transport properties in soft materials using thin, conformable resistive sensors [J].
Crawford, Kaitlyn E. ;
Ma, Yinji ;
Krishnan, Siddharth ;
Wei, Chen ;
Capua, Daniel ;
Xue, Yeguang ;
Xu, Shuai ;
Xie, Zhaoqian ;
Won, Sang Min ;
Tian, Limei ;
Webb, Chad ;
Li, Yajing ;
Feng, Xue ;
Huang, Yonggang ;
Rogers, John A. .
EXTREME MECHANICS LETTERS, 2018, 22 :27-35
[6]   The surface topography of silicone breast implants mediates the foreign body response in mice, rabbits and humans [J].
Doloff, Joshua C. ;
Veiseh, Omid ;
de Mezerville, Roberto ;
Sforza, Marcos ;
Perry, Tracy Ann ;
Haupt, Jennifer ;
Jamiel, Morgan ;
Chambers, Courtney ;
Nash, Amanda ;
Aghlara-Fotovat, Samira ;
Stelzel, Jessica L. ;
Bauer, Stuart J. ;
Neshat, Sarah Y. ;
Hancock, John ;
Romero, Natalia Araujo ;
Hidalgo, Yessica Elizondo ;
Leiva, Isaac Mora ;
Munhoz, Alexandre Mendonca ;
Bayat, Ardeshir ;
Kinney, Brian M. ;
Hodges, H. Courtney ;
Miranda, Roberto N. ;
Clemens, Mark W. ;
Langer, Robert .
NATURE BIOMEDICAL ENGINEERING, 2021, 5 (10) :1115-1130
[7]  
Ebong S, 1999, INFECT IMMUN, V67, P6603
[8]  
Edelstein CL, 2017, BIOMARKERS OF KIDNEY DISEASE, 2ND EDITION, P241, DOI 10.1016/B978-0-12-803014-1.00006-6
[9]   Discovery and Validation of a Urinary Exosome mRNA Signature for the Diagnosis of Human Kidney Transplant Rejection [J].
El Fekih, Rania ;
Hurley, James ;
Tadigotla, Vasisht ;
Alghamdi, Areej ;
Srivastava, Anand ;
Coticchia, Christine ;
Choi, John ;
Allos, Hazim ;
Yatim, Karim ;
Alhaddad, Juliano ;
Eskandari, Siawosh ;
Chu, Philip ;
Mihali, Albana B. ;
Lape, Isadora T. ;
Lima Filho, Mauricio P. ;
Aoyama, Bruno T. ;
Chandraker, Anil ;
Safa, Kassem ;
Markmann, James F. ;
Riella, Leonardo V. ;
Formica, Richard N. ;
Skog, Johan ;
Azzi, Jamil R. .
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2021, 32 (04) :994-1004
[10]  
Fernandes G., 1992, Biologic Rhythms in Clinical and Laboratory Medicine, P493