Validation of high-performance liquid chromatography coupled with LTQ orbitrap mass spectrometry for analysis of acrylamide

被引:2
|
作者
Omar, Mei Musa Ali [1 ]
Elbashir, Abdalla Ahmed [2 ,3 ]
Schmitz, Oliver J. [4 ]
Ziyada, Abobakr K. [5 ]
Osman, Abdelbagi [6 ,7 ]
机构
[1] Minist Sci & Technol, Cent Lab, POB 7099, Khartoum, Sudan
[2] Univ Khartoum, Fac Sci, Dept Chem, Khartoum 11115, Sudan
[3] King Faisal Univ, Coll Sci, Dept Chem, POB 400, Al Hasa 31982, Saudi Arabia
[4] Univ Duisburg Essen, Appl Analyt Chem, Fac Chem, Essen, Germany
[5] Jubail Ind Coll, Dept Gen Studies, POB 10099, Jubail Ind City 31961, Saudi Arabia
[6] Najran Univ, Coll Engn, Dept Chem Engn, POB 1988, Najran 11001, Saudi Arabia
[7] Najran Univ, Sci & Engn Res Ctr, POB 1988, Najran 11001, Saudi Arabia
关键词
Acrylamide; HPLC LTQ-Orbitrap MS; Carrez purification; Asparagine; Reducing sugars; FREE AMINO-ACIDS; EXTRACTION; ASPARAGINE; COFFEE; FOOD; PURIFICATION; SUGARS;
D O I
10.1007/s11694-023-02223-w
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Acrylamide is a food contaminant that forms through a natural chemical reaction between sugars and asparagine during high-temperature cooking processes. In this work an environmentally friendly and fast routine method for the analysis of acrylamide in Sudanese foods was successfully adapted. The method is based on sample extraction in water, purification with Carrez solutions and detection with high performance liquid chromatography-linear trap quadruple-Orbitrap-mass spectrometry (HPLC LTQ-Orbitrap MS). The performance of two analytical columns namely Kinetex C18 and Rezex ROA-organic acid was compared for acrylamide separation. The method was validated in term of linear range, limit of detection (LOD), limit of quantification (LOQ), precision (RSD%) and recovery. Good linearity (r(2) > 0.9988) was achieved using standard addition method in the concentration range 0-200 mu g kg(-1). The LOD is in the range from 3.24 to 4.66 mu g kg(-1) and 2.47 to 3.94 mu g kg(-1) for C18 and ROA columns, respectively. The precision of the method was <= 5.65% and 5.73% for C18 and ROA columns, respectively. Recoveries of acrylamide ranging from 86 to 98%, (n = 3) were obtained. It was successfully applied to the analysis of acrylamide in real food samples. Moreover, acrylamide precursors (free asparagine and reducing sugars) were analysed to show the relationship between their concentrations and acrylamide-forming potential.
引用
收藏
页码:930 / 939
页数:10
相关论文
共 50 条
  • [41] Analysis of acrylamide in food by isotope-dilution liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Riediker, S
    Stadler, RH
    JOURNAL OF CHROMATOGRAPHY A, 2003, 1020 (01) : 121 - 130
  • [42] Determination of Acrylamide in Biscuits by High-Resolution Orbitrap Mass Spectrometry: A Novel Application
    Fernandes, Cristiana L.
    Carvalho, Daniel O.
    Guido, Luis F.
    FOODS, 2019, 8 (12)
  • [43] Simultaneous detection of 22 mycotoxins in grape by QuEChERS and --ultra-high-performance liquid chromatography coupled with quadrupole/orbitrap -high-resolution mass spectrometry
    Cao, Meirong
    Wang, Jing
    Wang, Mengtian
    Yuan, Xiaoxuan
    Zhang, Xu
    Ma, Junzhan
    Zhang, Yan
    Li, Qiang
    JOURNAL OF FUTURE FOODS, 2024, 4 (04): : 369 - 375
  • [44] Development and validation of rapid multiresidue and multi-class analysis for antibiotics and anthelmintics in feed by ultra-high-performance liquid chromatography coupled to tandem mass spectrometry
    Robert, Christelle
    Brasseur, Pierre-Yves
    Dubois, Michel
    Delahaut, Philippe
    Gillard, Nathalie
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2016, 33 (08): : 1312 - 1323
  • [45] Determination of sixteen pesticides in peppers using high-performance liquid chromatography/mass spectrometry
    Morales, Ascension
    Ruiz, Irene
    Oliva, Jose
    Barba, Alberto
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART B-PESTICIDES FOOD CONTAMINANTS AND AGRICULTURAL WASTES, 2011, 46 (06) : 525 - 529
  • [46] Simultaneous determination of ginsenosides by high-performance liquid chromatography with tandem mass spectrometry detection
    I. A. Rodin
    A. N. Stavrianidi
    A. V. Braun
    O. A. Shpigun
    E. I. Berizovskaya
    Journal of Analytical Chemistry, 2014, 69 : 1252 - 1258
  • [47] Analysis of acrylamide in coffee and cocoa by isotope dilution liquid chromatography-tandem mass spectrometry
    Aguas, Patricia C.
    Fitzhenry, Matthew J.
    Giannikopoulos, Georgina
    Varelis, Peter
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 385 (08) : 1526 - 1531
  • [48] Analysis of caffeine, theobromine and theophylline in coffee by near infrared spectroscopy (NIRS) compared to high-performance liquid chromatography (HPLC) coupled to mass spectrometry
    Huck, CW
    Guggenbichler, W
    Bonn, GK
    ANALYTICA CHIMICA ACTA, 2005, 538 (1-2) : 195 - 203
  • [49] Determination of 63 mycotoxins in grain products by ultrahigh-performance liquid chromatography coupled with quadrupole-Orbitrap mass spectrometry
    Wu, Wenlin
    Huang, Xia
    Liang, Run
    Guo, Tianrong
    Xiao, Quanwei
    Xia, Bing
    Wan, Yuping
    Zhou, Yan
    FOOD CONTROL, 2023, 150
  • [50] Simultaneous determination of ginsenosides by high-performance liquid chromatography with tandem mass spectrometry detection
    Rodin, I. A.
    Stavrianidi, A. N.
    Braun, A. V.
    Shpigun, O. A.
    Berizovskaya, E. I.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 69 (13) : 1252 - 1258