Safety and Efficacy of a Novel Approach to Pulmonary Vein Isolation Using Prolonged Apneic Oxygenation

被引:6
|
作者
Gabriels, James K. [1 ]
Ying, Xiaohan [1 ]
Purkayastha, Subhanik [1 ]
Braunstein, Eric [1 ]
Liu, Christopher F. [1 ]
Markowitz, Steven M. [1 ]
Mountantonakis, Stavros [2 ]
Thomas, George [1 ]
Goldner, Bruce [3 ]
Willner, Jonathan [4 ]
Goyal, Rajat [5 ]
Ip, James E. [1 ]
Lerman, Bruce B. [1 ]
Carter, Jane [6 ]
Bereanda, Nicola [7 ]
Fitzgerald, Meghann M. [8 ]
Anca, Diana [8 ]
Patel, Apoor [9 ,11 ]
Cheung, Jim W. [1 ,10 ]
机构
[1] Weill Cornell Med New York Presbyterian Hosp, Dept Med, Div Cardiol, New York, NY USA
[2] Northwell Hlth, Lenox Hill Hosp, Div Cardiol, New York, NY USA
[3] Northwell Hlth, Long Isl Jewish Hosp, Div Electrophysiol, Queens, NY USA
[4] Northwell Hlth, North Shore Univ Hosp, Div Electrophysiol, Manhasset, NY USA
[5] Northwell Hlth, Southside Hosp, Div Electrophysiol, Bay Shore, NY USA
[6] Houston Methodist Hosp, Houston Methodist DeBakey Heart & Vasc Ctr, Dept Anesthesia, Houston, TX USA
[7] Northwell Hlth, Lenox Hill Hosp, Dept Anesthesia, New York, NY USA
[8] Weill Cornell Med New York Presbyterian Hosp, Dept Anesthesia, New York, NY USA
[9] Houston Methodist Hosp, Houston Methodist DeBakey Heart & Vasc Ctr, Dept Cardiol, Div Cardiac Electrophysiol, Houston, TX USA
[10] Weill Cornell Med, Div Cardiol, 520 East 70th St,4th Floor, New York, NY 10065 USA
[11] Houston Methodist Hosp, Div Cardiac Electrophysiol, 6550 Fannin St,Suite 1901, Houston, TX 77030 USA
关键词
apnea; atrial fibrillation; catheter stability; radiofrequency catheter ablation; FREQUENCY JET VENTILATION; CONTACT FORCE; ATRIAL-FIBRILLATION; CATHETER STABILITY; CONTROLLED-TRIAL; OBESE-PATIENTS; ABLATION; LARYNGOSCOPY; RESPIRATION; INDUCTION;
D O I
10.1016/j.jacep.2022.10.030
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Improved ablation catheter-tissue contact results in more effective ablation lesions. Respiratory motion causes catheter instability, which impacts durable pulmonary vein isolation (PVI). OBJECTIVES This study sought to evaluate the safety and efficacy of a novel ablation strategy involving prolonged periods of apneic oxygenation during PVI. METHODS We conducted a multicenter, prospective controlled study of 128 patients (mean age 63 +/- 11 years; 37% women) with paroxysmal atrial fibrillation undergoing PVI. Patients underwent PVI under general anesthesia using serial 4-minute runs of apneic oxygenation (apnea group; n = 64) or using standard ventilation settings (control group; n = 64). Procedural data, arterial blood gas samples, catheter position coordinates, and ablation lesion characteristics were collected. RESULTS Baseline characteristics between the 2 groups were similar. Catheter stability was significantly improved in the apnea group, as reflected by a decreased mean catheter displacement (1.55 +/- 0.97 mm vs 2.25 +/- 1.13 mm; P < 0.001) and contact force SD (4.9 +/- 1.1 g vs 5.2 +/- 1.5 g; P = 0.046). The percentage of lesions with a mean catheter displacement >2 mm was significantly lower in the apnea group (22% vs 44%; P < 0.001). Compared with the control group, the total ablation time to achieve PVI was reduced in the apnea group (18.8 +/- 6.9 minutes vs 23.4 +/- 7.8 minutes; P = 0.001). There were similar rates of first-pass PVI, acute PV reconnections and dormant PV reconnections between the two groups. CONCLUSIONS A novel strategy of performing complete PVI during apneic oxygenation results in improved catheter stability and decreased ablation times without adverse events. (Radiofrequency Ablation of Atrial Fibrillation Under Apnea; NCT04170894) (c) 2023 by the American College of Cardiology Foundation.
引用
收藏
页码:497 / 507
页数:11
相关论文
共 50 条
  • [31] Development, safety and efficacy of a novel circular-irrigated deca-channel mapping and ablation catheter for pulmonary vein isolation
    Xiang-Fei Feng
    Mu Chen
    Jian Sun
    Jie Sun
    Bo Liang
    Yi-Yong Sun
    Yi-Gang Li
    BMC Cardiovascular Disorders, 18
  • [32] Impact of Freezing Time and Balloon Size on the Thermodynamics and Isolation Efficacy During Pulmonary Vein Isolation Using the Second Generation Cryoballoon
    Takami, Mitsuru
    Lehmann, H. Immo
    Misiri, Juna
    Parker, Kay D.
    Sarmiento, Ray I.
    Johnson, Susan B.
    Packer, Douglas L.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2015, 8 (04) : 836 - 845
  • [33] The efficacy of apneic oxygenation during intubation using a prototype of an oxygenation laryngoscope - a technical simulation
    Wolfgang A Wetsch
    Daniel C Schroeder
    Susanne J Herff
    Bernd W Böttiger
    Volker Wenzel
    Holger Herff
    BMC Anesthesiology, 23
  • [34] Evaluation of Pulmonary Vein Stenosis After Pulmonary Vein Isolation Using a Novel Circular Mapping and Ablation Catheter (PVAC)
    von Bary, Christian
    Weber, Stefan
    Dornia, Christian
    Eissnert, Christoph
    Fellner, Claudia
    Latzin, Philipp
    Fredersdorf, Sabine
    Stadler, Stefan
    Hamer, Okka W.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2011, 4 (05) : 630 - 636
  • [35] Lesion index: a novel guide in the path of successful pulmonary vein isolation
    Antonio Dello Russo
    Gaetano M. Fassini
    Michela Casella
    Elena Romanelli
    Salvatore Pala
    Stefania Riva
    Valentina Catto
    Massimo Moltrasio
    Fabrizio Tundo
    Martina Zucchetti
    Benedetta Majocchi
    Maria Antonietta Dessanai
    Francesca Pizzamiglio
    Giulia Vettor
    Valentina Ribatti
    Alessio Gasperetti
    Selene Cellucci
    Gabriele Negro
    Rita Sicuso
    Corrado Carbucicchio
    Claudio Tondo
    Journal of Interventional Cardiac Electrophysiology, 2019, 55 : 27 - 34
  • [36] Efficacy of pulmonary vein isolation by cryoballon ablation in patients with paroxysmal atrial fibrillation
    Klein, Gunnar
    Oswald, Hanno
    Gardiwal, Ajmal
    Luesebrink, Ulrich
    Lissel, Christoph
    Yu, Hong
    Drexler, Helmut
    HEART RHYTHM, 2008, 5 (06) : 802 - 806
  • [37] Impact of general anesthesia on ablation catheter stability during pulmonary vein isolation based on a novel measurement approach
    Kuno, Shimpei
    Nakano, Yusuke
    Suzuki, Yasushi
    Ando, Hirohiko
    Suzuki, Wataru
    Takahashi, Hiroshi
    Amano, Tetsuya
    SCIENTIFIC REPORTS, 2023, 13 (01):
  • [38] Catheter ablation approach targeting epicardial connections to the right pulmonary vein antrum detected before pulmonary vein isolation
    Nakatani, Yosuke
    Take, Yutaka
    Yoshimura, Shingo
    Takizawa, Ryoya
    Goto, Koji
    Kaseno, Kenichi
    Haraguchi, Yumiko
    Kimura, Koki
    Sasaki, Takehito
    Miki, Yuko
    Nakamura, Kohki
    Naito, Shigeto
    HEART RHYTHM, 2025, 22 (02) : 443 - 451
  • [39] HotBalloon Pulmonary Vein Isolation Registry Study - Real-World Efficacy and Safety of HotBalloon Ablation -
    Yamasaki, Hiro
    Nakahara, Shiro
    Sohara, Hiroshi
    Yoshida, Yukihiko
    Kohno, Tsunesuke
    Shimane, Akira
    Miyauchi, Yasushi
    Kusano, Kengo
    Inden, Yasuya
    Yamane, Teiichi
    Aonuma, Kazutaka
    CIRCULATION JOURNAL, 2023, 87 (01) : 65 - +
  • [40] Efficacy and safety of novel temperature-controlled radiofrequency ablation system during pulmonary vein isolation in patients with paroxysmal atrial fibrillation: TRAC-AF study
    Starek, Zdenek
    Lehar, Frantisek
    Jez, Jiri
    Pesl, Martin
    Neuzil, Petr
    Sediva, Lucie
    Petru, Jan
    Dujka, Libor
    Funasako, Moritoshi
    Kautzner, Josef
    Peichl, Petr
    Aldhoon, Bashar
    Albenque, Jean-Paul
    Combes, Stephane
    Boveda, Serge
    Dukkipati, Srinivas R.
    Reddy, Vivek Y.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2022, 64 (02) : 375 - 381