摘要
PET reconstruction algorithms have long relied on sinogram rebinning. However, as detectors grow smaller in a recent wave of cutting-edge scanners, individual sensors no longer accrue hundreds of photons. Instead, most detect a single photon or none at all, effectively turning sinogram data into point-cloud measurements. The highly heterogeneous sensitivity of these scanners is another issue. We approach sinogram rebinning in the face of these challenges with a density-estimation framework that promotes knot sparsity in an underlying spline basis.
引用
收藏
页数:4
相关论文
共 13 条
  • [1] Exact and approximate rebinning algorithms for 3-D PET data
    Defrise, M
    Kinahan, PE
    Townsend, DW
    Michel, C
    Sibomana, M
    Newport, DF
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) : 145 - 158
  • [2] Continuous and discrete data rebinning in time-of-flight PET
    Defrise, Michel
    Panin, Vladimir
    Michel, Christian
    Casey, Michael E.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (09) : 1310 - 1322
  • [3] Convex Quantization Preserves Logconcavity
    del Aguila Pla, Pol
    Boquet-Pujadas, Aleix
    Jalden, Joakim
    [J]. IEEE SIGNAL PROCESSING LETTERS, 2022, 29 : 2697 - 2701
  • [4] Efficiency and time resolution of monolithic silicon pixel detectors in SiGe BiCMOS technology
    Iacobucci, G.
    Paolozzi, L.
    Valerio, P.
    Moretti, T.
    Cadoux, F.
    Cardarelli, R.
    Cardella, R.
    Debieux, S.
    Favre, Y.
    Ferrere, D.
    Gonzalez-Sevilla, S.
    Gurimskaya, Y.
    Kotitsa, R.
    Magliocca, C.
    Martinelli, F.
    Milanesio, M.
    Muenker, M.
    Nessi, M.
    Picardi, A.
    Saidi, J.
    Ruecker, H.
    Pinto, M. Vicente Barreto
    Zambito, S.
    [J]. JOURNAL OF INSTRUMENTATION, 2022, 17 (02)
  • [5] A STUDY OF LOGSPLINE DENSITY-ESTIMATION
    KOOPERBERG, C
    STONE, CJ
    [J]. COMPUTATIONAL STATISTICS & DATA ANALYSIS, 1991, 12 (03) : 327 - 347
  • [6] H2RSPET: a 0.5 mm resolution high-sensitivity small-animal PET scanner, a simulation study
    Lai, Youfang
    Wang, Qian
    Zhou, Shiwei
    Xie, Zhaoheng
    Qi, Jinyi
    Cherry, Simon R.
    Jin, Mingwu
    Chi, Yujie
    Du, Junwei
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (06)
  • [7] Hessian Schatten-Norm Regularization for Linear Inverse Problems
    Lefkimmiatis, Stamatios
    Ward, John Paul
    Unser, Michael
    [J]. IEEE TRANSACTIONS ON IMAGE PROCESSING, 2013, 22 (05) : 1873 - 1888
  • [8] IMPROVING "FAST ITERATIVE SHRINKAGE-THRESHOLDING ALGORITHM": FASTER, SMARTER, AND GREEDIER
    Liang, Jingwei
    Luo, Tao
    Schonlieb, Carola-Bibiane
    [J]. SIAM JOURNAL ON SCIENTIFIC COMPUTING, 2022, 44 (03) : A1069 - A1091
  • [9] 2-deoxy-2[18F]fluoro-D-mannose positron emission tomography imaging in atherosclerosis
    Tahara, Nobuhiro
    Mukherjee, Jogeshwar
    de Haas, Hans J.
    Petrov, Artiom D.
    Tawakol, Ahmed
    Haider, Nezam
    Tahara, Atsuko
    Constantinescu, Cristian C.
    Zhou, Jun
    Boersma, Hendrikus H.
    Imaizumi, Tsutomu
    Nakano, Masataka
    Finn, Aloke
    Fayad, Zahi
    Virmani, Renu
    Fuster, Valentin
    Bosca, Lisardo
    Narula, Jagat
    [J]. NATURE MEDICINE, 2014, 20 (02) : 215 - 219
  • [10] Positron emission tomography/computed tomography
    Townsend, David W.
    [J]. SEMINARS IN NUCLEAR MEDICINE, 2008, 38 (03) : 152 - 166