CT Reconstruction Algorithm and Low Contrast Detectability of Phantom Study: A Systematic Review and Meta-Analysis

被引:0
|
作者
Yusof, Nur Aimi Adibah [1 ]
Karim, Muhammad Khalis Abdul [1 ]
Asikin, Nursyazalina Mohd [1 ]
Paiman, Suriati [1 ]
Kechik, Mohd Mustafa Awang [1 ]
Rahman, Mohd Amiruddin Abdul [1 ]
Noor, Noramaliza Mohd [2 ]
机构
[1] Univ Putra Malaysia, Fac Sci, Dept Phys, Seri Kembangan 43400, Malaysia
[2] Univ Putra Malaysia, Fac Med, Dept Radiol, Seri Kembangan 43400, Malaysia
关键词
Computed tomography; phantom study; filtered back projection; low contrast detectability; iterative reconstruction; radiation; IMAGE QUALITY; ITERATIVE RECONSTRUCTION; COMPUTED-TOMOGRAPHY; SCAN PARAMETERS; PERFORMANCE; RESOLUTION;
D O I
10.2174/1573405618666220816160544
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background For almost three decades, computed tomography (CT) has been extensively used in medical diagnosis, which led researchers to conduct linking of CT dose exposure with image quality. Methods In this study, a systematic review and a meta-analysis study were conducted on CT phantom for resolution study especially based on the low contrast detectability (LCD). Furthermore, the association between the CT parameter such as tube voltage and the type of reconstruction algorithm, the amount of phantom scanning affecting the image quality and the exposure dose were also investigated in this study. We utilize PubMed, ScienceDirect, Google Scholar and Scopus databases to search related published articles from the year 2011 until 2020. The notable keywords comprise "computed tomography", "CT phantom", and "low contrast detectability". Of 52 articles, 20 articles are within the inclusion criteria in this systematic review. Results The dichotomous outcomes were chosen to represent the results in terms of risk ratio as per meta-analysis study. Notably, the noise in iterative reconstruction (IR) reduced by 24%, 33% and 36% with the use of smooth, medium and sharp filters, respectively. Furthermore, adaptive iterative dose reduction (AIDR 3D) improved image quality and the visibility of smaller less dense objects compared to filtered back-projection. Most of the researchers used 120 kVp tube voltage to scan phantom for quality assurance study. Conclusion Hence, optimizing primary factors such as tube potential reduces the dose exposure significantly, and the optimized IR technique could substantially reduce the radiation dose while maintaining the image quality.
引用
收藏
页码:1105 / 1113
页数:9
相关论文
共 50 条
  • [41] Diagnostic accuracy of contrast-enhanced CT for neck abscesses: A systematic review and meta-analysis of positive predictive value
    Hagelberg, Jon
    Pape, Bernd
    Heikkinen, Jaakko
    Nurminen, Janne
    Mattila, Kimmo
    Hirvonen, Jussi
    PLOS ONE, 2022, 17 (10):
  • [42] Dose Reduction and Low-Contrast Detectability Using Iterative CBCT Reconstruction Algorithm for Radiotherapy
    Washio, Hayate
    Ohira, Shingo
    Funama, Yoshinori
    Ueda, Yoshihiro
    Morimoto, Masahiro
    Kanayama, Naoyuki
    Isono, Masaru
    Inui, Shoki
    Nitta, Yuya
    Miyazaki, Masayoshi
    Teshima, Teruki
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2022, 21
  • [43] Effects of acquisition method and reconstruction algorithm for CT number measurement on standard-dose CT and reduced-dose CT: a QIBA phantom study
    Ohno, Yoshiharu
    Fujisawa, Yasuko
    Fujii, Kenji
    Sugihara, Naoki
    Kishida, Yuji
    Seki, Shinichiro
    Yoshikawa, Takeshi
    JAPANESE JOURNAL OF RADIOLOGY, 2019, 37 (05) : 399 - 411
  • [44] Volume estimation of low-contrast lesions with CT: a comparison of performances from a phantom study, simulations and theoretical analysis
    Li, Qin
    Gavrielides, Marios A.
    Zeng, Rongping
    Myers, Kyle J.
    Sahiner, Berkman
    Petrick, Nicholas
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (02) : 671 - 688
  • [45] Diagnostic accuracy of contrast-enhanced CT versus PET/CT for advanced ovarian cancer staging: a comparative systematic review and meta-analysis
    Wilson, Mitchell P.
    Sorour, Sara
    Bao, Bo
    Murad, Mohammad Hassan
    Man, Vincent
    Krill, Matthew
    Low, Gavin
    ABDOMINAL RADIOLOGY, 2024, 49 (06) : 2135 - 2144
  • [46] The effects of iterative reconstruction in CT on low-contrast liver lesion volumetry: a phantom study
    Li, Qin
    Berman, Benjamin P.
    Schumacher, Justin
    Liang, Yongguang
    Gavrielides, Marios A.
    Yang, Hao
    Zhao, Binsheng
    Petrick, Nicholas
    MEDICAL IMAGING 2017: COMPUTER-AIDED DIAGNOSIS, 2017, 10134
  • [47] Model-based iterative reconstruction for improvement of low-contrast detectability in liver CT at reduced radiation dose: ex-vivo experience
    Husarik, D. B.
    Alkadhi, H.
    Puippe, G. D.
    Reiner, C. S.
    Chuck, N. C.
    Morsbach, F.
    Szucs-Farkas, Z.
    Schindera, S. T.
    CLINICAL RADIOLOGY, 2015, 70 (04) : 366 - 372
  • [48] Accuracy of lung nodule volumetry in low-dose CT with iterative reconstruction: an anthropomorphic thoracic phantom study
    Doo, K. W.
    Kang, E-Y
    Yong, H. S.
    Woo, O. H.
    Lee, K. Y.
    Oh, Y-W
    BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1041)
  • [49] Diagnostic Accuracy of CT for the Detection of Hepatic Steatosis: A Systematic Review and Meta-Analysis
    Haghshomar, Maryam
    Antonacci, Dominic
    Smith, Andrew D.
    Thaker, Sarang
    Miller, Frank H.
    Borhani, Amir A.
    RADIOLOGY, 2024, 313 (02)
  • [50] The diagnostic performance of reduced-dose CT for suspected appendicitis in paediatric and adult patients: A systematic review and diagnostic meta-analysis
    Yoon, Hee Mang
    Suh, Chong Hyun
    Cho, Young Ah
    Kim, Jeong Rye
    Lee, Jin Seong
    Jung, Ah Young
    Kim, Jung Heon
    Lee, Jeong-Yong
    Kim, So Yeon
    EUROPEAN RADIOLOGY, 2018, 28 (06) : 2537 - 2548