CT Reconstruction Algorithm and Low Contrast Detectability of Phantom Study: A Systematic Review and Meta-Analysis

被引:0
|
作者
Yusof, Nur Aimi Adibah [1 ]
Karim, Muhammad Khalis Abdul [1 ]
Asikin, Nursyazalina Mohd [1 ]
Paiman, Suriati [1 ]
Kechik, Mohd Mustafa Awang [1 ]
Rahman, Mohd Amiruddin Abdul [1 ]
Noor, Noramaliza Mohd [2 ]
机构
[1] Univ Putra Malaysia, Fac Sci, Dept Phys, Seri Kembangan 43400, Malaysia
[2] Univ Putra Malaysia, Fac Med, Dept Radiol, Seri Kembangan 43400, Malaysia
关键词
Computed tomography; phantom study; filtered back projection; low contrast detectability; iterative reconstruction; radiation; IMAGE QUALITY; ITERATIVE RECONSTRUCTION; COMPUTED-TOMOGRAPHY; SCAN PARAMETERS; PERFORMANCE; RESOLUTION;
D O I
10.2174/1573405618666220816160544
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background For almost three decades, computed tomography (CT) has been extensively used in medical diagnosis, which led researchers to conduct linking of CT dose exposure with image quality. Methods In this study, a systematic review and a meta-analysis study were conducted on CT phantom for resolution study especially based on the low contrast detectability (LCD). Furthermore, the association between the CT parameter such as tube voltage and the type of reconstruction algorithm, the amount of phantom scanning affecting the image quality and the exposure dose were also investigated in this study. We utilize PubMed, ScienceDirect, Google Scholar and Scopus databases to search related published articles from the year 2011 until 2020. The notable keywords comprise "computed tomography", "CT phantom", and "low contrast detectability". Of 52 articles, 20 articles are within the inclusion criteria in this systematic review. Results The dichotomous outcomes were chosen to represent the results in terms of risk ratio as per meta-analysis study. Notably, the noise in iterative reconstruction (IR) reduced by 24%, 33% and 36% with the use of smooth, medium and sharp filters, respectively. Furthermore, adaptive iterative dose reduction (AIDR 3D) improved image quality and the visibility of smaller less dense objects compared to filtered back-projection. Most of the researchers used 120 kVp tube voltage to scan phantom for quality assurance study. Conclusion Hence, optimizing primary factors such as tube potential reduces the dose exposure significantly, and the optimized IR technique could substantially reduce the radiation dose while maintaining the image quality.
引用
收藏
页码:1105 / 1113
页数:9
相关论文
共 50 条
  • [21] Image quality and dose reduction opportunity of deep learning image reconstruction algorithm for CT: a phantom study
    Greffier, Joel
    Hamard, Aymeric
    Pereira, Fabricio
    Barrau, Corinne
    Pasquier, Hugo
    Beregi, Jean Paul
    Frandon, Julien
    EUROPEAN RADIOLOGY, 2020, 30 (07) : 3951 - 3959
  • [22] Accurate and efficient measurement of channelized Hotelling observer-based low-contrast detectability on the ACR CT accreditation phantom
    Fan, Mingdong
    Thayib, Theodore
    McCollough, Cynthia
    Yu, Lifeng
    MEDICAL PHYSICS, 2023, 50 (02) : 737 - 749
  • [23] Systematic assessment of coronary calcium detectability and quantification on four generations of CT reconstruction techniques: a patient and phantom study
    Dobrolinska, M. M.
    van Praagh, G. D.
    Oostveen, L. J.
    Poelhekken, K.
    Greuter, M. J. W.
    Fleischmann, D.
    Willemink, M. J.
    de Lange, F.
    Slart, R. H. J. A.
    Leiner, T.
    van der Werf, N. R.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2023, 39 (01) : 221 - 231
  • [24] CT enterography in obscure gastrointestinal bleeding: A systematic review and meta-analysis
    Wang, Zhen
    Chen, Jun-qiang
    Liu, Jin-lu
    Qin, Xin-gan
    Huang, Yuan
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2013, 57 (03) : 263 - 273
  • [25] Can low-dose CT with iterative reconstruction reduce both the radiation dose and the amount of iodine contrast medium in a dynamic CT study of the liver?
    Takahashi, Hiroto
    Okada, Masahiro
    Hyodo, Tomoko
    Hidaka, Syojiro
    Kagawa, Yuki
    Matsuki, Mitsuru
    Tsurusaki, Masakatsu
    Murakami, Takamichi
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (04) : 684 - 691
  • [26] Hybrid iterative reconstruction in ultra-low-dose CT for accurate pulmonary nodule assessment: A Phantom study
    Chen, Li-Guo
    Kao, Hung-Wen
    Wu, Ping-An
    Sheu, Ming-Huei
    Tu, Hsing-Yang
    Huang, Li-Chuan
    MEDICINE, 2025, 104 (08) : e41612
  • [27] Systematic Review and Meta-Analysis of CT Features for Differentiating Complicated and Uncomplicated Appendicitis
    Kim, Hae Young
    Park, Ji Hoon
    Lee, Yoon Jin
    Lee, Sung Soo
    Jeon, Jong-June
    Lee, Kyoung Ho
    RADIOLOGY, 2018, 287 (01) : 104 - 115
  • [28] Channelized hotelling observer-based low-contrast detectability on the ACR CT accreditation phantom: Part II. Repeatability study
    Fan, Mingdong
    Zhou, Zhongxing
    Mccollough, Cynthia
    Yu, Lifeng
    MEDICAL PHYSICS, 2024, 51 (03) : 1714 - 1725
  • [29] The effect of deep learning reconstruction on abdominal CT densitometry and image quality: a systematic review and meta-analysis
    van Stiphout, J. Abel
    Driessen, Jan
    Koetzier, Lennart R.
    Ruules, Lara B.
    Willemink, Martin J.
    Heemskerk, Jan W. T.
    van der Molen, Aart J.
    EUROPEAN RADIOLOGY, 2022, 32 (05) : 2921 - 2929
  • [30] Lung Cancer Screening with Low-Dose CT in Smokers: A Systematic Review and Meta-Analysis
    Hunger, Theresa
    Wanka-Pail, Eva
    Brix, Gunnar
    Griebel, Juergen
    DIAGNOSTICS, 2021, 11 (06) : NA