CT Reconstruction Algorithm and Low Contrast Detectability of Phantom Study: A Systematic Review and Meta-Analysis

被引:0
|
作者
Yusof, Nur Aimi Adibah [1 ]
Karim, Muhammad Khalis Abdul [1 ]
Asikin, Nursyazalina Mohd [1 ]
Paiman, Suriati [1 ]
Kechik, Mohd Mustafa Awang [1 ]
Rahman, Mohd Amiruddin Abdul [1 ]
Noor, Noramaliza Mohd [2 ]
机构
[1] Univ Putra Malaysia, Fac Sci, Dept Phys, Seri Kembangan 43400, Malaysia
[2] Univ Putra Malaysia, Fac Med, Dept Radiol, Seri Kembangan 43400, Malaysia
关键词
Computed tomography; phantom study; filtered back projection; low contrast detectability; iterative reconstruction; radiation; IMAGE QUALITY; ITERATIVE RECONSTRUCTION; COMPUTED-TOMOGRAPHY; SCAN PARAMETERS; PERFORMANCE; RESOLUTION;
D O I
10.2174/1573405618666220816160544
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background For almost three decades, computed tomography (CT) has been extensively used in medical diagnosis, which led researchers to conduct linking of CT dose exposure with image quality. Methods In this study, a systematic review and a meta-analysis study were conducted on CT phantom for resolution study especially based on the low contrast detectability (LCD). Furthermore, the association between the CT parameter such as tube voltage and the type of reconstruction algorithm, the amount of phantom scanning affecting the image quality and the exposure dose were also investigated in this study. We utilize PubMed, ScienceDirect, Google Scholar and Scopus databases to search related published articles from the year 2011 until 2020. The notable keywords comprise "computed tomography", "CT phantom", and "low contrast detectability". Of 52 articles, 20 articles are within the inclusion criteria in this systematic review. Results The dichotomous outcomes were chosen to represent the results in terms of risk ratio as per meta-analysis study. Notably, the noise in iterative reconstruction (IR) reduced by 24%, 33% and 36% with the use of smooth, medium and sharp filters, respectively. Furthermore, adaptive iterative dose reduction (AIDR 3D) improved image quality and the visibility of smaller less dense objects compared to filtered back-projection. Most of the researchers used 120 kVp tube voltage to scan phantom for quality assurance study. Conclusion Hence, optimizing primary factors such as tube potential reduces the dose exposure significantly, and the optimized IR technique could substantially reduce the radiation dose while maintaining the image quality.
引用
收藏
页码:1105 / 1113
页数:9
相关论文
共 50 条
  • [1] Iterative reconstruction with multifrequency signal recognition technology to improve low-contrast detectability: A phantom study
    Funama, Yoshinori
    Shirasaka, Takashi
    Goto, Taiga
    Aoki, Yuko
    Tanaka, Kana
    Yoshida, Ryo
    ACTA RADIOLOGICA OPEN, 2022, 11 (06)
  • [2] Evaluation of low-contrast detectability for iterative reconstruction in pediatric abdominal computed tomography: a phantom study
    Rubert, Nicholas
    Southard, Richard
    Hamman, Susan M.
    Robison, Ryan
    PEDIATRIC RADIOLOGY, 2020, 50 (03) : 345 - 356
  • [3] Effects of different levels of CT iterative reconstruction on low-contrast detectability and radiation dose in patients of different sizes: an anthropomorphic phantom study
    Rampado, Osvaldo
    Depaoli, Alessandro
    Marchisio, Filippo
    Gatti, Marco
    Racine, Damien
    Ruggeri, Valeria
    Ruggirello, Irene
    Darvizeh, Fatemeh
    Fonio, Paolo
    Ropolo, Roberto
    RADIOLOGIA MEDICA, 2021, 126 (01): : 55 - 62
  • [4] Evaluation of low-contrast detectability for iterative reconstruction in pediatric abdominal computed tomography: a phantom study
    Nicholas Rubert
    Richard Southard
    Susan M. Hamman
    Ryan Robison
    Pediatric Radiology, 2020, 50 : 345 - 356
  • [5] Effects of different levels of CT iterative reconstruction on low-contrast detectability and radiation dose in patients of different sizes: an anthropomorphic phantom study
    Osvaldo Rampado
    Alessandro Depaoli
    Filippo Marchisio
    Marco Gatti
    Damien Racine
    Valeria Ruggeri
    Irene Ruggirello
    Fatemeh Darvizeh
    Paolo Fonio
    Roberto Ropolo
    La radiologia medica, 2021, 126 : 55 - 62
  • [6] Deep-learning CT reconstruction in clinical scans of the abdomen: a systematic review and meta-analysis
    Shehata, Mostafa A.
    Saad, Abdelrahman M.
    Kamel, Serageldin
    Stanietzky, Nir
    Roman-Colon, Alicia M.
    Morani, Ajaykumar C.
    Elsayes, Khaled M.
    Jensen, Corey T.
    ABDOMINAL RADIOLOGY, 2023, 48 (08) : 2724 - 2756
  • [7] Influence of the adaptive iterative dose reduction 3D algorithm on the detectability of low-contrast lesions and radiation dose repeatability in abdominal computed tomography: a phantom study
    Yoon, Jeong Hee
    Lee, Jeong Min
    Hur, Bo Yun
    Baek, Jeehyun
    Shim, Hackjoon
    Han, Joon Koo
    Choi, Byung Ihn
    ABDOMINAL IMAGING, 2015, 40 (06): : 1843 - 1852
  • [8] Effects of various generations of iterative CT reconstruction algorithms on low-contrast detectability as a function of the effective abdominal diameter: A quantitative task-based phantom study
    Viry, Anais
    Aberle, Christoph
    Racine, Damien
    Knebel, Jean-Francois
    Schindera, Sebastian T.
    Schmidt, Sabine
    Becce, Fabio
    Verdun, Francis R.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 48 : 111 - 118
  • [9] Comparative performance analysis for abdominal phantom ROI detectability according to CT reconstruction algorithm: ADMIRE
    Shin, Jun-Bong
    Yoon, Do-Kun
    Pak, Seongyong
    Kwon, Yang-Ho
    Suh, Tae Suk
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (01): : 136 - 143
  • [10] Dose reduction with iterative reconstruction for coronary CT angiography: a systematic review and meta-analysis
    Den Harder, Annemarie M.
    Willemink, Martin J.
    De Ruiter, Quirina M. B.
    De Jong, Pim A.
    Schilham, Arnold M. R.
    Krestin, Gabriel P.
    Leiner, Tim
    Budde, Ricardo P. J.
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1058)