Double pulsed field gradient diffusion MRI to assess skeletal muscle microstructure

被引:3
|
作者
Berry, D. B. [1 ,2 ]
Galinsky, V. L. [3 ]
Hutchinson, E. B.
Galons, J. P. [4 ]
Ward, S. R. [1 ,5 ,6 ]
Frank, L. R. [3 ]
机构
[1] Univ Calif San Diego, Dept Orthoped Surg, San Diego, CA USA
[2] Univ Calif San Diego, Dept Nanoengn, San Diego, CA USA
[3] Univ Calif San Diego, Ctr Sci Computat Imaging, San Diego, CA USA
[4] Univ Arizona, Dept Med Imaging, Tucson, AZ USA
[5] Univ Calif San Diego, Dept Radiol, San Diego, CA USA
[6] Univ Calif San Diego, Dept Bioengn, San Diego, CA USA
基金
美国国家卫生研究院;
关键词
diffusion anisotropy; diffusion tensor imaging (DTI); diffusion tensor subspace imaging (DiTSI); double pulsed field gradient; skeletal muscle; PORE-SIZE DISTRIBUTION; IN-VIVO; MICROSCOPIC ANISOTROPY; WEIGHTING EXPERIMENTS; RELAXATION; MODEL; COEFFICIENT; DEPENDENCE; DIAMETER; MATTER;
D O I
10.1002/mrm.29751
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Preliminary study to determine whether double pulsed field gradient (PFG) diffusion MRI is sensitive to key features ofmuscle microstructure related to function. Methods: The restricted diffusion profile of molecules in models of muscle microstructure derived from histology were systematically simulated using a numerical simulation approach. Diffusion tensor subspace imaging analysis of the diffusion signalwas performed, and spherical anisotropy (SA) was calculated for each model. Linear regression was used to determine the predictive capacity of SA on the fiber area, fiber diameter, and surface area to volume ratio of the models. Additionally, a rat model of muscle hypertrophy was scanned using a single PFG and a double PFG pulse sequence, and the restricted diffusion measurements were compared with histological measurements of microstructure. Results: Excellent agreement between SA and muscle fiber area (r(2) = 0.71; p < 0.0001), fiber diameter (r(2) = 0.83; p < 0.0001), and surface area to volume ratio (r(2) = 0.97; p < 0.0001) in simulated models was found. In a scanned rat leg, the distribution of these microstructural features measured from histology was broad and demonstrated that there is a wide variance in the microstructural features observed, similar to the SA distributions. However, the distribution of fractional anisotropy measurements in the same tissue was narrow. Conclusions: This study demonstrates that SA-a scalar value from diffusion tensor subspace imaging analysis-is highly sensitive to muscle microstructural features predictive of function. Furthermore, these techniques and analysis tools can be translated to real experiments in skeletal muscle. The increased dynamic range of SA compared with fractional anisotropy in the same tissue suggests increased sensitivity to detecting changes in tissue microstructure.
引用
收藏
页码:1582 / 1593
页数:12
相关论文
共 48 条
  • [1] Diffusion tensor MRI to assess skeletal muscle disruption following eccentric exercise
    Cermak, Naomi M.
    Noseworthy, Michael D.
    Bourgeois, Jacqueline M.
    Tarnopolsky, Mark A.
    Gibala, Martin J.
    MUSCLE & NERVE, 2012, 46 (01) : 42 - 50
  • [2] Using double pulsed-field gradient MRI to study tissue microstructure in traumatic brain injury (TBI)
    Komlosh, Michal E.
    Benjamini, Dan
    Hutchinson, Elizabeth B.
    King, Sarah
    Haber, Margalit
    Avram, Alexandru V.
    Holtzclaw, Lynne A.
    Desai, Abhishek
    Pierpaoli, Carlo
    Basser, Peter J.
    MICROPOROUS AND MESOPOROUS MATERIALS, 2018, 269 : 156 - 159
  • [3] Accelerated, Physics-Inspired Inference of Skeletal Muscle Microstructure From Diffusion-Weighted MRI
    Naughton, Noel
    Cahoon, Stacey M.
    Sutton, Bradley P.
    Georgiadis, John G.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2024, 43 (11) : 3698 - 3709
  • [4] Feasibility of oscillating and pulsed gradient diffusion MRI to assess neonatal hypoxia-ischemia on clinical systems
    Gao, Fusheng
    Shen, Xiaoxia
    Zhang, Hongxi
    Ba, Ruicheng
    Ma, Xiaolu
    Lai, Can
    Zhang, Jiangyang
    Zhang, Yi
    Wu, Dan
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2021, 41 (06) : 1240 - 1250
  • [5] Relationships between tissue microstructure and the diffusion tensor in simulated skeletal muscle
    Berry, David B.
    Regner, Benjamin
    Galinsky, Vitaly
    Ward, Samuel R.
    Frank, Lawrence R.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (01) : 317 - 329
  • [6] Diffusion MRI with pulsed and free gradient waveforms: Effects of restricted diffusion and exchange
    Chakwizira, Arthur
    Westin, Carl-Fredrik
    Brabec, Jan
    Lasic, Samo
    Knutsson, Linda
    Szczepankiewicz, Filip
    Nilsson, Markus
    NMR IN BIOMEDICINE, 2023, 36 (01)
  • [7] Diffusion tensor MRI assessment of skeletal muscle architecture
    Heemskerk, Anneriet M.
    Damon, Bruce M.
    CURRENT MEDICAL IMAGING REVIEWS, 2007, 3 (03) : 152 - 160
  • [8] Estimation of pore size distribution using concentric double pulsed-field gradient NMR
    Benjamini, Dan
    Nevo, Uri
    JOURNAL OF MAGNETIC RESONANCE, 2013, 230 : 198 - 204
  • [9] Connecting Diffusion MRI to Skeletal Muscle Microstructure: Leveraging Meta-Models and GPU-acceleration
    Naughton, Noel
    Georgiadis, John
    PEARC '19: PROCEEDINGS OF THE PRACTICE AND EXPERIENCE IN ADVANCED RESEARCH COMPUTING ON RISE OF THE MACHINES (LEARNING), 2019,
  • [10] Measurement of the diffusion of multiple nuclei in restricted spaces by pulsed field gradient NMR
    Takekawa, Reiji
    Kawamura, Junichi
    JOURNAL OF MAGNETIC RESONANCE, 2021, 326