Intracochlear electrocochleography findings in cochlear implant recipients with auditory neuropathy spectrum disorder

被引:1
|
作者
Ulukan, Merve Bayri [1 ,2 ,4 ]
Ciprut, Ayca [3 ]
机构
[1] Marmara Univ, Hlth Sci Inst, Istanbul, Turkiye
[2] Cochlear, Istanbul, Turkiye
[3] Marmara Univ, Med Sch, Audiol Dept, Istanbul, Turkiye
[4] Marmara Univ Hosp, Pendik 10, TR-34899 Istanbul, Turkiye
关键词
Auditory neuropathy; Electrocochleography; Cochlear implant; Speech perception; Spectral resolution; HEARING PRESERVATION; SPEECH-PERCEPTION; RESIDUAL HEARING; CHILDREN; DIAGNOSIS; PERFORMANCE; THRESHOLDS; MECHANISM; OUTCOMES; ADULTS;
D O I
10.1016/j.ijporl.2023.111596
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objectives: This study aimed to compare intracochlear electrocochleography (ECochG) findings in a group of cochlear implant (CI) recipients with auditory neuropathy spectrum disorder (ANSD) with a group of CI recipients with sensorineural hearing loss (SNHL). Auditory outcome and spectral resolution findings were also compared among CI recipients with and without cochlear microphonic (CM) responses.Methods: This single-center, prospective cohort study was undertaken at a tertiary referral center. CM responses by the intracochlear ECochG test were recorded in CI recipients at 0.25-2 kHz. Speech, spatial, and hearing quality (SSQ) outcomes and spectral resolution measured with the spectral-temporally modulated ripple test were obtained for each recipient. The study included 62 implanted ears in 46 recipients, of which 59% (n = 27) were male and 41% (n = 19) were female. Twenty-nine ears with ANSD and 33 ears with SNHL were included. The mean age of the participants was 11 years. The results compared the intracochlear ECochG findings of the ANSD group with those of the SNHL group.Results: Participants were divided into two groups with and without obtainable CM responses. CM responses were obtained in 13 of 29 ears in the ANSD group and 14 of 33 ears in the SNHL group. CM thresholds obtained were better according to behavioral audiometric responses in some frequencies in the ANSD group. No significant difference was found in the auditory outcome and spectral resolution among CI recipients with and without CM responses.Conclusions: Intracochlear ECochG has a limited potential clinical value for monitoring ANSD. CM thresholds obtained using ECochG may not reflect behavioral hearing thresholds.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Postoperative Intracochlear Electrocochleography in Pediatric Cochlear Implant Recipients: Association to Audiometric Thresholds and Auditory Performance
    Attias, Joseph
    Ulanovski, David
    Hilly, Ohad
    Greenstein, Tally
    Sokolov, Merav
    HabibAllah, Suhail
    Mormer, Hen
    Raveh, Eyal
    EAR AND HEARING, 2020, 41 (05) : 1135 - 1143
  • [2] Extra- and Intracochlear Electrocochleography in Cochlear Implant Recipients
    Dalbert, Adrian
    Pfiffner, Flurin
    Roeoesli, Christof
    Thoele, Konrad
    Sim, Jae Hoon
    Gerig, Rahel
    Huber, Alexander M.
    AUDIOLOGY AND NEURO-OTOLOGY, 2015, 20 (05) : 339 - 348
  • [3] Intracochlear Electrocochleography and Speech Perception Scores in Cochlear Implant Recipients
    Valenzuela, Carla V.
    Lichtenhan, Jeffery T.
    Lefler, Shannon M.
    Koka, Kanthaiah
    Buchman, Craig A.
    Ortmann, Amanda J.
    LARYNGOSCOPE, 2021, 131 (10) : E2681 - E2688
  • [4] Music and psychoacoustic perception abilities in cochlear implant users with auditory neuropathy spectrum disorder
    Yuksel, Mustafa
    Ciprut, Ayca
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2020, 131
  • [5] Auditory neuropathy spectrum disorder (ANSD) and cochlear implantation
    Harrison, Robert V.
    Gordon, Karen A.
    Papsin, Blake C.
    Negandhi, Jaina
    James, Adrian L.
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2015, 79 (12) : 1980 - 1987
  • [6] Cortical Auditory Plasticity Following Cochlear Implantation in Children With Auditory Neuropathy Spectrum Disorder: A Prospective Study
    Saki, Nader
    Nikakhlagh, Soheila
    Moridi, Babak
    Karimi, Majid
    Aghayi, Azam
    Bayat, Arash
    OTOLOGY & NEUROTOLOGY, 2021, 42 (09) : E1227 - E1233
  • [7] Auditory Performance and Electrical Stimulation Measures in Cochlear Implant Recipients With Auditory Neuropathy Compared With Severe to Profound Sensorineural Hearing Loss
    Attias, Joseph
    Greenstein, Tally
    Peled, Miriam
    Ulanovski, David
    Wohlgelernter, Jay
    Raveh, Eyal
    EAR AND HEARING, 2017, 38 (02) : 184 - 193
  • [8] Intracochlear Recording of Electrocochleography During and After Cochlear Implant Insertion Dependent on the Location in the Cochlea
    Haumann, Sabine
    Timm, Max E.
    Buechner, Andreas
    Lenarz, Thomas
    Salcher, Rolf B.
    TRENDS IN HEARING, 2024, 28
  • [9] Clinical Applications of Intracochlear Electrocochleography in Cochlear Implant Users With Residual Acoustic Hearing
    Kim, Jeong-Seo
    JOURNAL OF AUDIOLOGY AND OTOLOGY, 2024, 28 (02) : 100 - 106
  • [10] Effect of age at cochlear implantation on auditory and speech development of children with auditory neuropathy spectrum disorder
    Liu, Yuying
    Dong, Ruijuan
    Li, Yuling
    Xu, Tianqiu
    Li, Yongxin
    Chen, Xueqing
    Gong, Shusheng
    AURIS NASUS LARYNX, 2014, 41 (06) : 502 - 506