Psychometric properties of a standardized protocol of muscle strength assessment by hand-held dynamometry in healthy adults: a reliability study

被引:12
|
作者
Morin, Marika [1 ]
Hebert, Luc J. [2 ,3 ,4 ,5 ]
Perron, Marc [2 ,3 ]
Petitclerc, Emilie [5 ]
Lake, Shanna-Rose [5 ]
Duchesne, Elise [1 ,4 ,6 ,7 ]
机构
[1] Univ Quebec Chicoutimi, Dept Hlth Sci, 555 Bd Univ, Chicoutimi, PQ G7H 2B1, Canada
[2] Univ Laval, Fac Med, Dept Rehabil, Quebec City, PQ, Canada
[3] Univ Laval, Fac Med, Dept Radiol & Nucl Med, Quebec City, PQ, Canada
[4] Integrated Univ Ctr Hlth & Social Serv Saguenay L, Interdisciplinary Res Grp Neuromuscular Dis GRIMN, Jonquiere, PQ, Canada
[5] Integrated Univ Ctr Hlth & Social Serv Capitale N, Interdisciplinary Res Ctr Rehabil & Social Integr, Quebec City, PQ, Canada
[6] Univ Quebec Chicoutimi, Intersectoral Ctr Sustainable Hlth, Chicoutimi, PQ, Canada
[7] Res Ctr Charles Le Moyne CRCLM, Sherbrooke, PQ, Canada
关键词
Hand-held dynamometry; Muscle strength; Psychometric properties; Quantitative evaluation; Reliability; Standard error of measurement; Minimal detectable change; ISOKINETIC DYNAMOMETRY; KNEE; VALIDITY; BELT; HIP;
D O I
10.1186/s12891-023-06400-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundMaximal isometric muscle strength (MIMS) assessment is a key component of physiotherapists' work. Hand-held dynamometry (HHD) is a simple and quick method to obtain quantified MIMS values that have been shown to be valid, reliable, and more responsive than manual muscle testing. However, the lack of MIMS reference values for several muscle groups in healthy adults with well-known psychometric properties limits the use and the interpretation of these measures obtained with HHD in clinic.ObjectiveTo determine the intra- and inter-rater reliability, standard error of measurement (SEM) and minimal detectable change (MDC) of MIMS torque values obtained with HHD.MethodsIntra and Inter-rater Reliability Study. The MIMS torque of 17 muscle groups was assessed by two independent raters at three different times in 30 healthy adults using a standardized HHD protocol using the MEDup (TM) (Atlas Medic, Quebec, Canada). Participants were excluded if they presented any of the following criteria: 1) participation in sport at a competitive level; 2) degenerative or neuromusculoskeletal disease that could affect torque measurements; 3) traumatic experience or disease in the previous years that could affect their muscle function; and 4) use of medication that could impact muscle strength (e.g., muscle relaxants, analgesics, opioids) at the time of the evaluation. Intra- and inter-rater reliability were determined using two-way mixed (intra) and random effects (inter) absolute agreement intraclass correlation coefficients (ICC: 95% confidence interval) models. SEM and MDC were calculated from these data.ResultsIntra- and inter-rater reliability were excellent with ICC (95% confidence interval) varying from 0.90 to 0.99 (0.85-0.99) and 0.89 to 0.99 (0.55-0.995), respectively. Absolute SEM and MDC for intra-rater reliability ranged from 0.14 to 3.20 Nm and 0.38 to 8.87 Nm, respectively, and from 0.17 to 5.80 Nm and 0.47 to 16.06 Nm for inter-rater reliability, respectively.ConclusionsThe excellent reliability obtained in this study suggest that the use of such a standardized HHD protocol is a method of choice for MIMS torque measurements in both clinical and research settings. And the identification of the now known metrological qualities of such a protocol should encourage and promote the optimal use of manual dynamometry.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Inter-rater and intra-rater reliability of belt-stabilized hand-held dynamometer using make test in lower extremity muscle strength assessment among healthy adults
    Espino, Reil Vinard S.
    Gonzalez-Suarez, Consuelo
    Ingram, Lewis A.
    Gomez, Ivan Neil B.
    Agarao, Kris Anthony T.
    Flores, Jazzmine Gale
    Bulseco, Nicole
    INTERNATIONAL JOURNAL OF OSTEOPATHIC MEDICINE, 2025, 56
  • [42] Assessment of Isometric Knee Flexor Strength Using Hand-Held Dynamometry in High-Level Rugby Players Is Intertester Reliable
    van der Made, Anne D.
    Paget, Liam D. A.
    Altink, J. Nienke
    Reurink, Gustaaf
    Six, Willem R.
    Tol, Johannes L.
    Kerkhoffs, Gino M.
    CLINICAL JOURNAL OF SPORT MEDICINE, 2021, 31 (05): : E271 - E276
  • [43] Reliability of the ForceFrame With and Without a Fixed Upper-Limb Mold in Shoulder Rotation Strength Assessments Compared With Traditional Hand-Held Dynamometry
    Couch, Jamon
    Sayers, Marc
    Pizzari, Tania
    JOURNAL OF SPORT REHABILITATION, 2021, 30 (08) : 1246 - 1249
  • [44] Inter-Tester Reliability and Precision of Manual Muscle Testing and Hand-Held Dynamometry in Lower Limb Muscles of Children with Spina Bifida
    Mahony, Kate
    Hunt, Adrienne
    Daley, Deborah
    Sims, Susan
    Adams, Roger
    PHYSICAL & OCCUPATIONAL THERAPY IN PEDIATRICS, 2009, 29 (01) : 44 - 59
  • [45] Intra- and Inter-Rater Reliability of Strength Measurements Using a Pull Hand-Held Dynamometer Fixed to the Examiner's Body and Comparison with Push Dynamometry
    Gonzalez-Rosalen, Javier
    Benitez-Martinez, Josep Carles
    Medina-Mirapeix, Francesc
    Cuerda-Del Pino, Alba
    Cervello, Antonio
    Martin-San Agustin, Rodrigo
    DIAGNOSTICS, 2021, 11 (07)
  • [46] Reliability of isometric knee extension muscle strength measurements made by a hand-held dynamometer and a belt: a comparison of two types of device
    Katoh, Munenori
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2015, 27 (03) : 851 - 854
  • [47] Reliability of two devices for shoulder strength assessment: Wii Fit Balance Board and hand-held dynamometer
    Intelangelo, Leonardo
    Elias, Gonzalo
    Lassaga, Ignacio
    Bustos, Cristian
    Jerez-Mayorga, Daniel
    SHOULDER & ELBOW, 2024, 16 (1_SUPPL) : 110 - 118
  • [48] Dynamometry for the assessment of trunk muscle strength in postpartum women with pregnancy-related posterior pelvic girdle pain: A reliability study
    Jafarian, Fahimeh-Sadat
    Jafari-Harandi, Mahmonir
    Yeowell, Gillian
    Sadeghi-Demneh, Ebrahim
    INTERNATIONAL JOURNAL OF OSTEOPATHIC MEDICINE, 2024, 54
  • [49] Intrarater and interrater reliability of hand held dynamometer for healthy quadriceps femoris: the effect of muscle strength
    Telci, Emine Aslan
    Aslan, Ummuhan Bas
    Cavlak, Ugur
    CLINICAL AND EXPERIMENTAL HEALTH SCIENCES, 2011, 1 (02): : 124 - 128
  • [50] Assessment of foot and ankle muscle strength using hand held dynamometry in patients with established rheumatoid arthritis
    Matthew Carroll
    Angela Brenton-Rule
    William Joyce
    Nicola Dalbeth
    Keith Rome
    Journal of Foot and Ankle Research, 6 (Suppl 1)