Psychometric properties of a standardized protocol of muscle strength assessment by hand-held dynamometry in healthy adults: a reliability study

被引:12
|
作者
Morin, Marika [1 ]
Hebert, Luc J. [2 ,3 ,4 ,5 ]
Perron, Marc [2 ,3 ]
Petitclerc, Emilie [5 ]
Lake, Shanna-Rose [5 ]
Duchesne, Elise [1 ,4 ,6 ,7 ]
机构
[1] Univ Quebec Chicoutimi, Dept Hlth Sci, 555 Bd Univ, Chicoutimi, PQ G7H 2B1, Canada
[2] Univ Laval, Fac Med, Dept Rehabil, Quebec City, PQ, Canada
[3] Univ Laval, Fac Med, Dept Radiol & Nucl Med, Quebec City, PQ, Canada
[4] Integrated Univ Ctr Hlth & Social Serv Saguenay L, Interdisciplinary Res Grp Neuromuscular Dis GRIMN, Jonquiere, PQ, Canada
[5] Integrated Univ Ctr Hlth & Social Serv Capitale N, Interdisciplinary Res Ctr Rehabil & Social Integr, Quebec City, PQ, Canada
[6] Univ Quebec Chicoutimi, Intersectoral Ctr Sustainable Hlth, Chicoutimi, PQ, Canada
[7] Res Ctr Charles Le Moyne CRCLM, Sherbrooke, PQ, Canada
关键词
Hand-held dynamometry; Muscle strength; Psychometric properties; Quantitative evaluation; Reliability; Standard error of measurement; Minimal detectable change; ISOKINETIC DYNAMOMETRY; KNEE; VALIDITY; BELT; HIP;
D O I
10.1186/s12891-023-06400-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundMaximal isometric muscle strength (MIMS) assessment is a key component of physiotherapists' work. Hand-held dynamometry (HHD) is a simple and quick method to obtain quantified MIMS values that have been shown to be valid, reliable, and more responsive than manual muscle testing. However, the lack of MIMS reference values for several muscle groups in healthy adults with well-known psychometric properties limits the use and the interpretation of these measures obtained with HHD in clinic.ObjectiveTo determine the intra- and inter-rater reliability, standard error of measurement (SEM) and minimal detectable change (MDC) of MIMS torque values obtained with HHD.MethodsIntra and Inter-rater Reliability Study. The MIMS torque of 17 muscle groups was assessed by two independent raters at three different times in 30 healthy adults using a standardized HHD protocol using the MEDup (TM) (Atlas Medic, Quebec, Canada). Participants were excluded if they presented any of the following criteria: 1) participation in sport at a competitive level; 2) degenerative or neuromusculoskeletal disease that could affect torque measurements; 3) traumatic experience or disease in the previous years that could affect their muscle function; and 4) use of medication that could impact muscle strength (e.g., muscle relaxants, analgesics, opioids) at the time of the evaluation. Intra- and inter-rater reliability were determined using two-way mixed (intra) and random effects (inter) absolute agreement intraclass correlation coefficients (ICC: 95% confidence interval) models. SEM and MDC were calculated from these data.ResultsIntra- and inter-rater reliability were excellent with ICC (95% confidence interval) varying from 0.90 to 0.99 (0.85-0.99) and 0.89 to 0.99 (0.55-0.995), respectively. Absolute SEM and MDC for intra-rater reliability ranged from 0.14 to 3.20 Nm and 0.38 to 8.87 Nm, respectively, and from 0.17 to 5.80 Nm and 0.47 to 16.06 Nm for inter-rater reliability, respectively.ConclusionsThe excellent reliability obtained in this study suggest that the use of such a standardized HHD protocol is a method of choice for MIMS torque measurements in both clinical and research settings. And the identification of the now known metrological qualities of such a protocol should encourage and promote the optimal use of manual dynamometry.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] RELIABILITY OF HAND-HELD DYNAMOMETRY AND ITS RELATIONSHIP WITH MANUAL MUSCLE TESTING IN PATIENTS WITH OSTEOARTHRITIS IN THE KNEE
    HAYES, KW
    FALCONER, J
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1992, 16 (03) : 145 - 149
  • [32] Literature reporting normative data for muscle strength measured by hand-held dynamometry: A systematic review
    Bohannon, Richard W.
    ISOKINETICS AND EXERCISE SCIENCE, 2011, 19 (03) : 143 - 147
  • [33] Hand-Held Dynamometry in the Inpatient Care Setting After Total Knee Arthroplasty Reliability of Static Knee Strength Measurements
    Eymir, Musa
    Yuksel, Ertugrul
    Unver, Bayram
    Karatosun, Vasfi
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2021, 100 (06) : 570 - 575
  • [34] Reliability of maximal isometric knee strength testing with modified hand-held dynamometry in patients awaiting total knee arthroplasty: useful in research and individual patient settings? A reliability study
    Koblbauer, Ian F. H.
    Lambrecht, Yannick
    van der Hulst, Micheline L. M.
    Neeter, Camille
    Engelbert, Raoul H. H.
    Poolman, Rudolf W.
    Scholtes, Vanessa A.
    BMC MUSCULOSKELETAL DISORDERS, 2011, 12
  • [35] Hand-held dynamometry fixated with a tripod is reliable for assessment of back extensor strength in women with osteoporosis
    Valentin, G.
    Maribo, T.
    OSTEOPOROSIS INTERNATIONAL, 2014, 25 (08) : 2143 - 2149
  • [36] Manual muscle testing and hand-held dynamometry in people with inflammatory myopathy: An intra- and interrater reliability and validity study
    Pfister, Pierrette Baschung
    de Bruin, Eling D.
    Sterkele, Iris
    Maurer, Britta
    de Bie, Rob A.
    Knols, Ruud H.
    PLOS ONE, 2018, 13 (03):
  • [37] Maximal isometric muscle strength values obtained By hand-held dynamometry in children between 6 and 15 years of age
    Escobar, Raul G.
    Munoz, Karin T.
    Dominguez, Angelica
    Banados, Pamela
    Bravo, Maria J.
    MUSCLE & NERVE, 2017, 55 (01) : 16 - 22
  • [38] Reliability of Hand-Held Dynamometer for assessing Isometric Lumbar Muscles Strength in Asymptomatic Healthy Population
    Tanveer, Fahad
    Arslan, Syed Asadullah
    Darain, Haider
    Ahmad, Ashfaq
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2021, 37 (02) : 461 - 465
  • [39] Enhancing the examiner's resisting force improves the reliability of manual muscle strength measurements: Comparison of a new device with hand-held dynamometry
    Lu, Tung-Wu
    Hsu, Horng-Chaung
    Chang, Ling-Ying
    Chen, Hao-Ling
    JOURNAL OF REHABILITATION MEDICINE, 2007, 39 (09) : 679 - 684
  • [40] Hand-held dynamometry in patients with haematological malignancies: Measurement error in the clinical assessment of knee extension strength
    Ruud H Knols
    Geert Aufdemkampe
    Eling D de Bruin
    Daniel Uebelhart
    Neil K Aaronson
    BMC Musculoskeletal Disorders, 10